![Binks 104197 Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/binks/104197/104197_service-manual_2752857027.webp)
EN
The unit must be removed to be drained, maintained and filled with oil.
Note:
After filling with fresh oil, refit the level and/or drain plugs and clean up any oil spillage.
Maintenance
WARNING
Wait until the unit has cooled sufficiently after stopping and isolation.
Gearbox
Every 1000 hours verify the good condition of oil seals and gaskets
The gearbox is supplied factory fitted with oil and is a service free unit.
However if seals start to leak and oil level is reduced, both the affected seal and oil need to be replaced as a
general overhaul of the unit.
If changing the oil place a suitable container underneath the plug for draining.
Maintenance
Gearbox
General overhauls must only be done by authorised ATEX certified service personnel or companies.
It is recommended that the oil should be warm [40-50º C] to facilitate easier draining.
77-3245 R1.0
27/36
www.carlisleft.com