background image

Instruction Manual 

 

 

 

Page 6 of 28 

Issue: 2.2

 

Specification – Section 1.3

 

 
 
 

Specification 

Pump Nominal Stroke 

50 mm 

1.97 ins 

Pump Ratio 

3:1 

Nominal Flow Volume / Cycle 

0..375 Litres 

0.10 US Gall 

Fluid Output @ 60 cycles/min 
 

22.5 Litres / min 

6.0 US Gall / min 

Maximum Recommended Continuous Cycle Rate 

 

Maximum Recommended Intermittent Cycle Rate 

20 Cycles /min 

 

40 Cycles /min 

Fluid Inlet / Outlet Connections 

1” Sanitary 

 

 

Air Volume / cycle

 

0.17 SCFM (4.8 L/m) @ 45PSI (3.1 Bar) 

0.33 SCFM (9.3 L/m) @ 90 PSI (6.2 Bar)

 

Air Flow @ 15 cycles/min 6 bar 
Air Flow @ 30 cycles/min 6 bar 

5 CFM  (142 L/min) 

10 CFM  (283 L/min)

 

Air Quality ISO 8573.1 Class 3.3.2 # See Note 

Dirt       5 microns 

Water -20ºC@7bar (940ppm) 

Oil        0.1mg/m³ 

 

 

 

Total Weight of Pump 

21 Kg 

46 Lb 

 

 

# Note: Class 3.4.2 Air Quality (Refrigerant dried - water +

3ºC@7bar) 

may be used, 

however, above 15 cycles/min optional heavy duty mufflers 192821 or piped exhaust 
system should be used. 

Содержание 104009

Страница 1: ...Instruction Manual For Maple 15 Pump Model 104009...

Страница 2: ...Instruction Manual Page 2 of 28 Issue 2 2...

Страница 3: ...tant Safety Information 3 1 Installation General 4 1 Parts Lists Main Pump 4 2 Parts Lists Air Motor 4 3 Parts Lists Fluid Section 4 4 Parts Lists Reference 5 1 Maintenance Air Motor Assembly Procedur...

Страница 4: ...r valves to control the air motor reversal providing reciprocating motion The air valve design patent pending ensures a positive magnetic detent for the main and pilot air valves thus removing the pos...

Страница 5: ...main spool valve is air piloted and contains two exhaust ports Both the pilot valves and the main spool valve are easily removable There are no external air pilot hoses The air logic and exhaust port...

Страница 6: ...min 40 Cycles min Fluid Inlet Outlet Connections 1 Sanitary Air Volume cycle 0 17 SCFM 4 8 L m 45PSI 3 1 Bar 0 33 SCFM 9 3 L m 90 PSI 6 2 Bar Air Flow 15 cycles min 6 bar Air Flow 30 cycles min 6 bar...

Страница 7: ...Instruction Manual Page 7 of 28 Issue 2 2 Dimensions and Mounting Details Section 1 4 For Piped Exhaust Air remove mufflers and add 192803 Plug and Adapter 192779 for 1 NB Hose...

Страница 8: ...and maintenance should only be carried out by suitably qualified personnel 1 Before attempting any work on a high pressure system ensure material pump hydraulics compressed air motor are isolated whe...

Страница 9: ...ot turn on or off any light switch in the spray dispense area while operating or if fumes are present Do not operate a gasoline engine in the spray dispense area Hot Surface Hazard The electric motor...

Страница 10: ...ulator to the air motor Filter rated at minimum 1000 L min No additional air lubrication is required as piston o ring lubricant is applied during assembly or repair If an air lubricator is used to pro...

Отзывы: