Instruction Manual
Page 6 of 28
Issue: 2.2
Specification – Section 1.3
Specification
Pump Nominal Stroke
50 mm
1.97 ins
Pump Ratio
3:1
Nominal Flow Volume / Cycle
0..375 Litres
0.10 US Gall
Fluid Output @ 60 cycles/min
22.5 Litres / min
6.0 US Gall / min
Maximum Recommended Continuous Cycle Rate
Maximum Recommended Intermittent Cycle Rate
20 Cycles /min
40 Cycles /min
Fluid Inlet / Outlet Connections
1” Sanitary
Air Volume / cycle
0.17 SCFM (4.8 L/m) @ 45PSI (3.1 Bar)
0.33 SCFM (9.3 L/m) @ 90 PSI (6.2 Bar)
Air Flow @ 15 cycles/min 6 bar
Air Flow @ 30 cycles/min 6 bar
5 CFM (142 L/min)
10 CFM (283 L/min)
Air Quality ISO 8573.1 Class 3.3.2 # See Note
Dirt 5 microns
Water -20ºC@7bar (940ppm)
Oil 0.1mg/m³
Total Weight of Pump
21 Kg
46 Lb
# Note: Class 3.4.2 Air Quality (Refrigerant dried - water +
3ºC@7bar)
may be used,
however, above 15 cycles/min optional heavy duty mufflers 192821 or piped exhaust
system should be used.