Bindicator SERIAL COMMUNICATION ADAPTERS Скачать руководство пользователя страница 6

Serial Communication Adapters  

Instruction Manual 

6

 

RS-485 SERIAL ADAPTER 

 

Description 

The RS-485 serial adapter converts the serial output of the PRD1000 
meter to balanced, full or half-duplex RS-485 signals. 

 

The RS-485 serial adapter has a removable screw terminal connector 
for the RS-485 terminals which includes Transmit Data (DO) and (/DO), 
Receive Data (DI) and (/DI), and Signal Ground. The adapter is provid-
ed by the PRD1000 meter M-Link connection. 

 

Baud rates are adjustable and handled by the PRD1000 (see the 
PRD1000 Instruction Manual for more details). 

 

The RS-485 serial adapter has three diagnostic LEDs: a Power (P) LED 
to show when the adapter is powered properly, a Transmit Data (TX) 
LED to show when the adapter is sending data out from the PC side, 
and a Receive Data (RX) LED to show when the adapter is receiving 
data from the PRD1000 meter. 

Содержание SERIAL COMMUNICATION ADAPTERS

Страница 1: ...www bindicator com 150 Venture Blvd Spartanburg SC 29306 Tel 800 778 9242 Fax 864 574 8063 Email sales bindicator com SERIAL COMMUNICATION ADAPTERS Instruction Manual...

Страница 2: ...erchantability or fitness for a particular purpose Registered Trademarks All trademarks mentioned in this document are the property of their re spective owners 2013 Bindicator All rights reserved SAFE...

Страница 3: ...NICATIONS OVERVIEW 5 RS 485 SERIAL ADAPTER 6 Description 6 Installation 7 PRD1000 Serial Communication Address serIAl 7 Connections 9 USB SERIAL ADAPTER 10 Description 10 Installation 10 TROUBLESHOOTI...

Страница 4: ...y PRD1000 meter M Link connection STATUS INDICATION Separate LEDs for Power P Transmit TX and Receive RX USB Serial Adapter COMPATIBILITY USB 1 1 USB 2 0 CONNECTORS RJ45 and USB Type B CABLE One 6 1 8...

Страница 5: ...tion of a network The differential data transmission of RS 485 offers superi or performance in most applications Differential signals can help nullify the effects of ground shifts and induced noise si...

Страница 6: ...smit Data DO and DO Receive Data DI and DI and Signal Ground The adapter is provid ed by the PRD1000 meter M Link connection Baud rates are adjustable and handled by the PRD1000 see the PRD1000 Instru...

Страница 7: ...000 Serial Communication Address serIAl When using more than one meter in a multi drop or multi point mode each meter must be provided with its own unique address For the PRD1000 meter the address may...

Страница 8: ...nufacturer for recommendations 2 Use shielded cable twisted pairs plus ground Connect ground shield only at one location Figure 2 RS 485 Two Wire Multi Drop Wiring Notes 1 Termination resistors are op...

Страница 9: ...duplex RS 485 four wire network device Figure 3 Connections for RS 485 Adapter to Serial Converter If the RS 485 device configured for a two wire network then the re quirement to externally wire the...

Страница 10: ...SERIAL ADAPTER Description The USB Serial Adapter allows for direct connection of a PRD1000 me ter to the USB port of a PC Installation Figure 22 shows the connection of a PRD1000 meter to a PC using...

Страница 11: ...rate 4 Software address and baud rate If only the TX or DATA IN data status LED is flashing when serial communications attempted Check 1 Serial adapter and cable 2 Serial protocol selected 3 Meter ad...