background image

 

Issue 05/2016 

Art. No. 7001-0081

 

 
 
 

Operating Manual

 

 
 

BF – Incubators with forced convection

 

with microprocessor temperature controller  

 

Model 

Model version 

Art. No. 

BF 53 

BF053-230V 

9010-0235, 9110-0235 

BF 53-UL 

BF053UL-120V 

9010-0236, 9110-0236 

BF 115 

BF115-230V 

9010-0237, 9110-0237 

BF 115-UL 

BF115UL-120V 

9010-0238, 9110-0238 

BF 240 

BF240-230V 

9010-0239, 9110-0239 

BF 240-UL 

BF240UL-120V 

9010-0240, 9110-0240 

BF 400 

BF400-230V 

9010-0241, 9110-0241 

BF 400-UL 

BF400UL-120V 

9010-0242, 9110-0242 

BF 720 

BF720-230V 

9010-0243, 9110-0243 

BF 720-UL 

BF720UL-120V 

9010-0244, 9110-0244 

 
 
 
 

BINDER GmbH 

Address 

Post office box 102 

 

D-78502 Tuttlingen 

Tel. 

+49 7462 2005 0 

Fax 

+49 7462 2005 100 

Internet 

http://www.binder-world.com 

E-mail 

[email protected] 

Service Hotline 

+49 7462 2005 555 

Service Fax 

+49 7462 2005 93 555 

Service E-Mail 

[email protected] 

Service Hotline USA  

+1 866 885 9794 or +1 631 224 4340 x3 

Service Hotline Asia Pacific  

+852 390 705 04 or +852 390 705 03 

Service Hotline Russia and CIS  +7 495 988 15 16

 

 

Содержание BF 115

Страница 1: ...BF 400 BF400 230V 9010 0241 9110 0241 BF 400 UL BF400UL 120V 9010 0242 9110 0242 BF 720 BF720 230V 9010 0243 9110 0243 BF 720 UL BF720UL 120V 9010 0244 9110 0244 BINDER GmbH Address Post office box 1...

Страница 2: ...7 6 CONTROLLER SETTING 17 6 1 Display entry of temperature and ventilation set points without ramp function 17 6 2 Display entry of temperature and ventilation set points with selected temperature ram...

Страница 3: ...U 38 11 TROUBLESHOOTING 39 12 TECHNICAL DESCRIPTION 40 12 1 Factory calibration and adjustment 40 12 2 Definition of usable volume 40 12 3 Over current protection 40 12 4 Technical data 41 12 5 Equipm...

Страница 4: ...n this operating manual are prerequisites for hazard free use and safety during operation and maintenance In no event shall BINDER be held liable for any damages direct or incidental arising out of or...

Страница 5: ...n its proximity 1 2 2 Safety alert symbol Use of the safety alert symbol indicates a risk of injury Observe all measures that are marked with the safety alert symbol in order to avoid death or injury...

Страница 6: ...in the same way in order to avoid disruptions that could result in direct or indirect injury or property damage 1 3 Localization position of safety labels on the chamber The following labels are loca...

Страница 7: ...nal Special application acc to project no 0 40 kW Nominal power 1 8 A Nominal current 230 V 50 Hz Nominal voltage 10 at the indicated power frequency 230 V 60 Hz 1 N Current type With option internal...

Страница 8: ...chambers With regard to operating the chambers and to the installation location please observe the DGUV guidelines 213 850 on safe working in laboratories formerly BGI GUV I 850 0 BGR GUV R 120 or ZH...

Страница 9: ...and its behavior with the addition of heat energy Familiarize yourself with any potential health risks caused by the charging material the contained moisture constituent or by reaction products that...

Страница 10: ...rving the instructions in this operating manual and conducting regular maintenance work chap 9 is part of the intended use WARNING If customer should use a BINDER chamber running in non supervised con...

Страница 11: ...ent AISI 304 The housing is RAL 7035 powder coated All corners and edges are also completely coated All chamber functions are easy and comfortable to use thanks to their clear arrangement Major featur...

Страница 12: ...sport the chamber using the door handle or the door Do NOT lift chambers size 400 and 720 by hand Lift chambers size 53 and 115 from the pallet at its four lower corners with the aid of 2 people chamb...

Страница 13: ...four lower corners Place chambers size 400 and 720 using technical devices fork lifter on the transport pallet Set the fork lifter only from the rear in the middle of the chamber Make sure to place a...

Страница 14: ...y 70 r H max non condensing Installation height max 3000 m 9842 ft above sea level When placing several chambers of the same size side by side maintain a minimum distance of 160 mm between each chambe...

Страница 15: ...ied data located on the chamber s type plate chamber front behind the door bottom left hand chap 1 4 When connecting please observe the regulations specified by the local electricity supply company an...

Страница 16: ...ly we recommend heating up the chamber to its nominal temperature for one day and in a well ventilated location 1 Insert the plug into an appropriate socket chap 4 1 The green Standby LED illuminates...

Страница 17: ...splay The actual temperature value example 21 8 C is displayed 1 Press button The display shows alternately SP and the previous temperature set point example 60 C 2 With the buttons enter a set point...

Страница 18: ...re value example 21 8 C is displayed 1 Press button The display shows alternately SPr and the actual temperature ramp set point changing according to the selected gradient example 42 7 C This ramp set...

Страница 19: ...t1 time function and the time function Continuous operation t inf The heating is permanently active independent of the timer setting Timer operation The display shows alternately t1 time function and...

Страница 20: ...Timer operation Timer not programmed or run down Press button to return to normal display actual value display automatically after approx 30 sec 6 3 2 Continuous operation 1 Press the time management...

Страница 21: ...tered value The use of this time depends on the timer function selected in the user menu chap 6 4 4 5 Press button to return to normal display actual value display automatically after approx 30 second...

Страница 22: ...n Timer function chap 6 4 4 Press button Setting the interface mode and if appropriate the printer interval chap 6 4 5 Figure 5 Press down button for approx 5 seconds Press button to return to normal...

Страница 23: ...equired The use of temperature ramps may result in the heating up times being considerably slowed down The entry in C min or in F min meaning the nominal value gradient and limits the maximum temperat...

Страница 24: ...gradient from the previously entered set point to the new one SP The actual value follows the set point value About set point display during ramp operation see chap 6 2 6 4 3 Chamber addressing If sev...

Страница 25: ...set point After the defined time has expired the heating is turned off Delayed on setting 2 After the time set has passed the heating is turned on and remain in continuous operation 1 Press down butt...

Страница 26: ...n button The display alternately shows PFCt and the actual setting of the interface mode 6 Set the desired interface mode with buttons Settings Modbus 0 printer 1 In case of temperature data acquisiti...

Страница 27: ...ime management button The controller displays the actual time function If necessary select the time function Timer operation chap 6 3 1 In the entry level enter the desired time 3 00 chap 6 3 3 6 6 Ge...

Страница 28: ...dible alarm with activated buzzer chap 8 1 by the buzzer sounding proceed as follows Disconnect the chamber from the power supply Have an expert examine and rectify the cause of the fault Restart the...

Страница 29: ...safety device s regulatory function Proceed as described in chap 7 8 2 Communication software APT COM 3 DataControlSystem option The chamber is regularly equipped with a serial interface RS 422 that...

Страница 30: ...perature option With this option the chamber is equipped with an analog output 4 20 mA for temperature This output permits transmitting data to external data registration systems or devices The connec...

Страница 31: ...rical hazard Danger of death Damage to the internal socket Do NOT exceed the temperature set point of 90 C 194 F Set the mechanical thermostat class 3 1 to 90 C 194 F Heat emission of electrical devic...

Страница 32: ...e consult BINDER Service BINDER telephone hotline 49 0 7462 2005 555 BINDER fax hotline 49 0 7462 2005 93555 BINDER e mail hotline service binder world com BINDER service hotline USA 1 866 885 9794 or...

Страница 33: ...eaning products please contact BINDER service We recommend using the neutral cleaning agent Art No Art Nr 1002 0016 for a thorough cleaning Any corrosive damage that may arise following use of other c...

Страница 34: ...rface disinfectants free from acid or halides Alcohol based solutions We recommend using the disinfectant spray Art No 1002 0022 For chemical disinfection we recommend using the disinfectant spray Art...

Страница 35: ...hone prior to your sending the BINDER product back to us The authorization number will be issued following receipt of the information below BINDER product type and serial number Date of purchase Name...

Страница 36: ...0 5 10 3 Disposal of the chamber in the Federal Republic of Germany According to Annex I of Directive 2012 19 EU of the European Parliament and of the Council on waste electrical and electronic equipm...

Страница 37: ...aw Fill out the contamination clearance certificate chap 13 and enclose it with the chamber WARNING Contamination of the device with toxic infectious or radioactive substances Danger of intoxication D...

Страница 38: ...ior to disposal clean all introduced or residual toxic substances from the chamber Prior to disposal disinfect the chamber from all sources of infection Be aware that sources of infection may also be...

Страница 39: ...ontinuous operation chap 6 3 Semiconductor relay defective Contact BINDER service Controller defective Chamber without function only the green stand by LED is lit Chamber in stand by mode Press down t...

Страница 40: ...x A b 0 1x B c 0 1 x C VUSE A 2a x B 2b x C 2c Figure 9 Determination of the useable volume The technical data refers to the defined usable volume Do NOT place samples outside this usable volume Do NO...

Страница 41: ...90 600 23 62 800 31 50 1200 47 24 Depth mm inch 330 12 99 400 15 75 500 19 69 500 19 69 600 23 62 Interior volume l cu ft 53 1 9 115 4 1 240 8 6 400 14 3 720 25 7 Steam space volume l cu ft 70 2 47 14...

Страница 42: ...h 11 20 33 53 80 All technical data is specified for unloaded chambers with standard equipment at an ambient temperature of 22 C 3 C 71 6 F 5 4 F and a power supply voltage fluctuation of 10 Technica...

Страница 43: ...r qualified personnel authorized by BINDER perform all maintenance and repair and if components relating to chamber safety are replaced in the event of failure with original spare parts The user is re...

Страница 44: ...IQ OQ PQ DL440500 Calibration service Calibration of temperature including certificate 1 measuring point DL300101 Spatial temperature measurement including certificate 9 measuring points DL300109 Spat...

Страница 45: ...BF E1 05 2016 page 45 58 13 Certificates and declarations of conformity 13 1 EU Declaration of Conformity...

Страница 46: ...BF E1 05 2016 page 46 58...

Страница 47: ...page 47 58 13 2 Certificate for the GS mark of conformity of the VDE Pr f und Zertifizierungsinstitut Testing and Certification Institute of the Association for Electrical Electronic and Information...

Страница 48: ...BF E1 05 2016 page 48 58...

Страница 49: ...BF E1 05 2016 page 49 58...

Страница 50: ...BF E1 05 2016 page 50 58...

Страница 51: ...BF E1 05 2016 page 51 58...

Страница 52: ...BF E1 05 2016 page 52 58 14 Product registration...

Страница 53: ...nformation vorliegt bevor das Ger t Bauteil eintrifft Eine weitere Kopie soll dem Ger t Bauteil beigef gt sein Ggf ist auch die Spedition zu informieren Incomplete information or non conformity with t...

Страница 54: ...substances weder giftige noch sonstige gef hrliche Stoffe enth lt oder solche anhaften That eventually generated reaction products are non toxic and also do not represent a hazard auch evtl entstande...

Страница 55: ...n entsteht haften und BINDER gegen eventuell entstehende Schadenanspr che Dritter freistellen We are aware that in accordance with Article 823 of the German Civil Code BGB we are directly liable with...

Страница 56: ...y time Take notice of shipping laws and regulations Please fill Reason for return request Duplicate order Duplicate shipment Demo Page one completed by sales Power Plug Voltage 115V 230 V 208 V 240V S...

Страница 57: ..._____________________________________________________________ c ____________________________________________________________________________ 3 2 Safety measures required for handling the list under 3...

Страница 58: ...all damages that are a consequence of incomplete or incorrect information provided by us and that we will indemnify and hold harmless BINDER Inc from eventual damage claims by third parties Name _____...

Страница 59: ......

Отзывы: