IMPORTANT SAFETY INSTRUCTIONS 

To reduce the risk of fire or electric shock, read and follow all instructions and warnings in this 
manual. Keep this manual for future reference.

1.  Do not expose to water.

2.  Do not remove cover. No user serviceable parts inside. 

3.  Clean only with a dry cloth.

4.  Leave sufficient space between devices and do not block ventilation holes for proper 

cooling.

5.  Do not stack transmitter or receivers on top of each other.

6.  Do not install near any device or source that generates heat.

7.  Do not install near any heat sources such as radiators, heat registers, stoves or other 

apparatus (including amplifiers) that produce heat.

8.  Do not override the safety purpose of the polarized or grounding plug. A polarized plug has 

two blades, one of which is wider than the other. A grounding plug has two matching blades 
and a third grounding prong. The wide blade or the third prong is provided for your safety. If 
the provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet.

9.  Protect the power cord from being walked on or pinched, particularly at the plug end and 

where the power cord is attached to the apparatus.

10. Only use manufacturer’s recommended power supply if the use of an external power supply 

for the transmitter and receiver is necessary. 

11. Only use attachments and accessories specified by the manufacturer.

12. Refer all servicing to qualified service personnel. Servicing is required when the apparatus 

has been damaged in any way, such as when the power supply cord or plug is damaged, 
liquid has been spilled on or objects have fallen into the apparatus, the apparatus has 
been exposed to rain or moisture, the apparatus does not operate normally, or it has been 
dropped.

13. Disconnect the power supply cord from the power outlet, or disconnect the transmitter 

and receivers from the network PoE connections or remove the network switch power cord 
from the outlet, to completely disconnect the controller from power.

Содержание B-900-MOIP-4K-CTRL

Страница 1: ...Source Mute 2ch HDMI Out Audio INSTALLATION SETUP GUIDE MEDIA OVER IP SYSTEM B 900 MOIP 4K CTRL B 900 MOIP 4K TX B 900 MOIP 4K RX ...

Страница 2: ...2 ...

Страница 3: ...s provided for your safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 9 Protect the power cord from being walked on or pinched particularly at the plug end and where the power cord is attached to the apparatus 10 Only use manufacturer s recommended power supply if the use of an external power supply for the transmitter and recei...

Страница 4: ...OLLER Reboot Factory Default Network 5VDC A Status LED Solid during system boot Blinks during normal operation B Reboot Button Use a pin to press the recessed button to restart C USB Ports Not used for the MoIP system D Network LAN Port Connect to MoIP switch to provide access to MoIP transmitters and receivers E HDMI Port Not used for the MoIP system F 12 VDC Power Connection Connect the power su...

Страница 5: ... DTE DCE E 3 5 mm Input Analog Audio embedding to replace HDMI audio F L R Audio Out RCA Analog audio de embedding of 2 channel PCM audio G RS 232 RJ45 RS 232 TX RX Ground EIA 561 pin out H HDMI IN OUT HDMI source input and HDMI loop output for local display I IR Receiver 3 5 mm mini Mono Stereo for external receivers J IR Flasher 3 5 mm mini Mono Stereo output to IR emitter K Factory Reset Press ...

Страница 6: ... On Off Switch 2 DTE DCE E 3 5 mm Input Analog Audio embedding to replace HDMI audio F L R Audio Out RCA Analog audio de embedding of 2 channel PCM audio G RS 232 RJ45 RS 232 TX RX Ground EIA 561 pin out H HDMI OUT HDMI source input and HDMI loop output for local display I IR Receiver 3 5 mm mini Mono Stereo for external receivers J IR Flasher 3 5 mm mini Mono Stereo output to IR emitter flasher K...

Страница 7: ...t Leave Instant Leave Immediate Leave Jumbo Frames Jumbo Packets Maximum Transmission Unit 8000 bytes or larger 7 5 Watts PoE power per port for each transmitter and receiver no external power supplies are provided with each transmitter or receiver Recommended Network Topology Binary s 900 series MoIP system can be deployed across multiple network topology to support most applications We recommend...

Страница 8: ... TX 2 MoIP TX 3 MoIP TX 4 MoIP TX 5 HDMI HDMI HDMI IR 2 IR 2 IR 3 IR 1 Cat5e Cat5e Cat5e Cat5e Cat5e Cat5e Cat5e Cat5e Cat5e Cat5e Stereo Output Stereo Input 1 5 HDMI Receiver 4K Display 1 4K HDR Display 2 4K Display 3 1080p Display 4 Crown CD 1000 Amp 801e Amp IR 1 Multiple Sources with Video Wall Network 5VDC MoIP Switch IR IR IR IR MoIP RX 1 MoIP RX 2 MoIP RX 3 MoIP RX 4 MoIP Controller HDMI Bl...

Страница 9: ...et button for 10 15 seconds until the Status LED flashes once This will reboot the switch and reset to factory settings 2 Connect the dedicated MoIP switch directly to your Main LAN switch The Main LAN switch is the main network switch into which all other switches and network devices are connected The Main LAN switch is the only switch connected to the router A dedicated MoIP switch is preferred ...

Страница 10: ...m and is acceptable 4 Setup the MoIP Controller Claim MoIP controller on OvrC and access the local UI IMPORTANT This is REQUIRED for firmware maintenance 1 For existing OvrC locations a Log into OvrC and go to Customer Devices b A new device will show ready to add Click Device Media Devices and follow the prompts to claim the MoIP controller ...

Страница 11: ... IP Settings and click Enable Apply a static address to the MoIP controller on the same ip address range Click Save to apply 6 Update the MoIP Controller Firmware Available firmware updates are visible in the Device List for that location in OvrC Follow steps provided in OvrC to complete 7 Power off the MoIP Switch then Connect Devices 1 Connect sources via HDMI to the MoIP Transmitters 2 Connect ...

Страница 12: ...e The discovery process will identify all transmitters and receivers on the system and displays Devices will be discovered and assigned a transmitter or receiver number Transmitter and receiver numbers will correlate directly with the inputs or outputs respectively for control system integration similar to traditional matrix switchers ...

Страница 13: ...oot until all have completed update status 11 Identify Receiver Display and Transmitter Source Pairs Recommended 1 Click the i under each device to name each transmitter Use the screen capture from each source to help identify each transmitter 2 Record the Transmitter number MAC address and connected source for use during control system integration 3 Activate Identify Mode via the MoIP controller ...

Страница 14: ...oIP Receiver has limited audio capabilities please configure the MoIP Transmitters to limit the audio EDID presented to the source to the most common format 5 1 or 2ch a If the MoIP Transmitter Audio EDID to 2 Channel Stereo all MoIP Receivers will hear the 2 channel stereo audio from the HDMI source b All TVs in the system can process 5 1 Dolby Digital and DTS 5 1 but only the home theater AVR ca...

Страница 15: ...15 ...

Страница 16: ...ugh for the displays capable of support 4K HDR as this will allow the HDR metadata to pass resulting in 4K HDR 30Hz 3 Set each receiver to 2160p 30Hz to displays that are 4K however do not support HDR Note The video output resolution can be set to 2160p 4K at 30Hz or 25Hz or 1080p 2K at 60Hz or 50Hz Since each receiver always outputs 4K 30Hz 4 4 4 8 bit color 4K HDR will be limited to 8 bit color ...

Страница 17: ...wall required 2 Select the video wall size 2x2 3x3 4x4 by clicking the matching size 3 Based on your installation assign a given receiver to each position PX of the video wall 4 Measure the display screen dimensions as indicated to adjust out the video that falls behind each TV bezel 5 Click Enable to adjust the bezel 6 Enter the dimensions 7 Click Save The updated video wall receivers are now ava...

Страница 18: ...r link each transmitter and receiver s serial port to the devices to be controlled Refer to the Serial IR Control document for more information Infrared IR Routing Infrared control signals are passed bi directionally over the static routes establish on the IR Links Settings page on the MoIP controller local user interface UI These routes create virtual wires simplifying the integration process To ...

Страница 19: ...modified or disassembled Products to be repaired under this warranty must be returned to a designated service center with an assigned return authorization number RA Contact technical support for an RA number SUPPORT Need Help Contact Tech Support If you need further clarification please call tech support at 866 838 5052 or email support snapav com For other information instructional videos support...

Страница 20: ...Rev 180710 1030 2018 Binary ...