Binary B-520-EXT-330-RS-IP Скачать руководство пользователя страница 2

2

IMPORTANT SAFETY INSTRUCTIONS 

To reduce the risk of fire or electric shock, read and follow all instructions and warnings in this 
manual. Keep this manual for future reference.

1.  Do not expose this apparatus to rain or moisture. Do not expose this equipment to dripping 

or splashing, and ensure that no objects filled with liquids, such as vases, are placed on the 
equipment. Do not use this apparatus near water.

2.  Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service 

personnel.

3.  Clean only with a dry cloth.

4.  Do not block any ventilation openings. Install according to manufacturer’s instructions.

5.  Do not install near any heat sources such as radiators, heat registers, stoves or other 

apparatus (including amplifiers) that produce heat.

6.  Do not override the safety purpose of the polarized or grounding plug. A polarized plug has 

two blades, one of which is wider than the other. A grounding plug has two matching blades 
and a third grounding prong. The wide blade or the third prong is provided for your safety. If 
the provided plug does not fit into your outlet, consult an electrician for replacement of the 
obsolete outlet.

7.  Protect the power cord from being walked on or pinched, particularly at the plug end and 

where the power cord is attached to the apparatus.

8.  Only use attachments and accessories specified by the manufacturer.

9.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus 

has been damaged in any way, such as when the power supply cord or plug is damaged, 
liquid has been spilled on or objects have fallen into the apparatus, the apparatus has 
been exposed to rain or moisture, the apparatus does not operate normally, or it has been 
dropped.

10. To completely disconnect this equipment from power, disconnect the power supply cord 

from the power outlet.

The lightning flash with arrowhead symbol, within 
an equilateral triangle, is intended to alert the user 
to the presence of uninsulated dangerous voltage 
within the product’s enclosure that may be of 
sufficient magnitude to constitute a risk of electric 
shock to persons.
The exclamation point within an equilateral triangle 
is intended to alert the user to the presence of 
important operating and maintenance (servicing) 
instructions in the literature accompanying the 
appliance.

CAUTION

 TO REDUCE THE RISK OF ELECTRICAL 

SHOCK:

DO NOT REMOVE COVER. NO USER 

SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED 
SERVICE PERSONNEL.

Содержание B-520-EXT-330-RS-IP

Страница 1: ...Source Mute 2ch HDMI Out Audio INSTALLATION MANUAL HDBaseT EXTENDER B 520 EXT 330 RS IP...

Страница 2: ...acement of the obsolete outlet 7 Protect the power cord from being walked on or pinched particularly at the plug end and where the power cord is attached to the apparatus 8 Only use attachments and ac...

Страница 3: ...ontrol Connections 8 6 2 1 Point to Point IR Control Stereo 3 5mm IR Receiver 9 6 2 2 Control System Mono 3 5mm IR Receiver 9 6 2 3 IR Flasher Out 3 5mm Mono Transmitter and Receiver 10 6 3 RS 232 Con...

Страница 4: ...ither end Additionally the design has been improved to solve the clock stretching issue that can arise with cable boxes when used with HDBaseT extenders 2 FEATURES Improved design to support clock str...

Страница 5: ...el Adjusts the intensity of the IR Flasher output H Ethernet RJ45 To communicate IP data between Transmitter and Receiver I DIP Switches IR RCVR PWR OFF ON OFF to connect to control system ON to conne...

Страница 6: ...and Receiver H DIP Switches IR RCVR PWR OFF ON OFF to connect to control system ON to connect to IR Receiver DCE DTE To select if serial RS232 communication via DB 9 is in DCE or DTE mode LINK SERVIC...

Страница 7: ...ired location 3 Connect the category cable to the receiver 4 Connect an IR flasher and or IR receiver if being used Refer to Section 6 2 5 Connect an HDMI cable from the HDMI Out of receiver to the di...

Страница 8: ...ectional IR signals can be transmitted between transmitter and receiver through category cable The IR signal can be generated either from a powered receiver or from a control system The following sect...

Страница 9: ...to this connection as damage may occur 1 2 3 4 ON 1 ON 2 3 9V DC Sleeve GND Ring IR Signal Tip FIGURE 6 Point to Point IR settings 6 2 2 Control System Mono 3 5mm IR Receiver When using a control syst...

Страница 10: ...d between the device transmitter and receiver over the category cable The transmitter may be connected to a control system and the receiver may be connected to an RS 232 controllable device Front 1 2...

Страница 11: ...device is DTE Typically the control system will be DTE and the controlled device will be DCE however devices may vary Refer to the manual for the connected devices for proper pinout configuration 2 1...

Страница 12: ...RE 11 Firmware Update settings 6 4 IP Control Connections Bi directional Ethernet signals are transmitted between the B 520 EXT 330 RS IP Transmitter and Receiver over the Cat5e 6 cable The most commo...

Страница 13: ...isplay connected to the HDMI out on the transmitter and or the display connected to the HDMI out on the receiver 6 6 1 Auto EDID When the EDID DIP switch is set to AUTO the lowest common EDID setting...

Страница 14: ...or 330 Full HD 1080p 36 bit color 330 Ultra HD 4K2K 30 Hz 330 Input TMDS Signal 1 2V peak to peak Input DDC Signal 5V peak to peak TTL ESD Protection 1 Human body model 5kV air gap discharge 8kV conta...

Страница 15: ...e information instructional videos support documentation and ideas visit our website and view your item s product page at www snapav com 9 WARRANTY 2 Year Limited Warranty This Binary Product has a 2...

Страница 16: ...Rev 150806 1100 2015 Binary...

Отзывы: