10
6.2.3. IR Flasher Out-3.5mm Mono – Transmitter and Receiver
The IR Flasher level adjusts the intensity of the IR Flasher output
GND (Sleeve)
IR Signal (Tip)
FIGURE 8: IR Flasher Out
6.3. RS-232 Control Connections
Bidirectional RS-232 signals are transmitted between the device transmitter and receiver over
the category cable. The transmitter may be connected to a control system and the receiver may
be connected to an RS-232 controllable device.
Front
1
2 3
4
ON
1
ON
2
3
A
B
A
B
FIGURE 9: RS-232 Connections
RS-232 Control (DB-9)- See Section 6.3.1
HDBaseT Link category - See Section 6.1
Pinout Configuration
B-520-EXT-330-RS-IP Transmitter
RS-232 Controllable
Device
Control
System
B-520-EXT-330-RS-IP Receiver