20
ATTENTION!
When the equipment is off and you are going to handle the skewer that contains the forks,
take the utmost care. The forks are very sharp and can easily cause accidents (cuts, for
example) if not handled carefully.
It is extremely important that the products used for cleaning ensure maximum hygiene and
that they are non-toxic.
5.2 Breakdown Maintenance and Procedures
The operator must be instructed to carry out routine inspections, making small adjustments,
cleaning and observing signs of breakdowns that may occur. Examples include: checking for strange
noises indicating gas leaks; burners that do not light; the non-execution by the equipment to the
service to which it is proposed; among others. Actions like these are indispensable to guarantee a
longer equipment life.
ATTENTION!
When maintenance is carried out (even if minor adjustments are made), always check that the
equipment has the burners off, the pressure regulator (register) of the gas closed and the
equipment be at room temperature.
It is recommended that each 6 months be made preventive maintenance, checking and
adjusting the loose, cleaning the internal parts, and others. Detecting broke parts or without the
correct functionality the worker needs to exchange the parts, always using original parts only.
By carrying out preventive maintenance, the inconvenience of having the equipment stopped
when it is most needed is eliminated, the cost of maintenance is reduced and the risk of accidents is
reduced.
Follow the equipment maintenance and adjustment recommendations:
• Change the pressure regulator every 5 years or when it is defective;
• After use, keep the gas valve closed, avoiding pressure on the hose;
• The gas injector on the burner must always be unobstructed. If they become clogged, use a needle
for cleaning on stove tops;
• The ideal flame should be blue.
ATTENTION!
Preventive maintenance requires a trained professional.
Whenever an item related to the safety of the equipment is removed (such as when performing
maintenance), put it back in its proper place and confirm that they are performing their
function correctly.
Detecting broke parts or without the correct functionality, please contact the nearest
authorized service center.