Setting the Max. and Min. Display Values
Set the maximum and minimum display values to limit the range of pressures displayed on the
DPS LCD display. To set the maximum display value, press and hold the “UP” button for at least
three seconds. To set the minimum display value, press and hold the “DOWN” button for at
least three seconds.
Setting ID
Value
Measurement
Mode
or
>3s
PE*
100.0
99.9
Measurement
Mode
*
PE
= Upper display limit,
bo
= Lower display limit
Setting Up the Key Lock Function
The key lock function prevents unauthorized users from making changes to the switch settings.
To enable the key lock, press and hold the “SET” and “UP” buttons together for at least three
seconds. Use the arrow keys to select “on”. Press “SET” to save and exit. To disable the key
lock,
repeat the process but select “off”.
Setting ID
Value
Measurement
Mode
+
>3s
Lock Setting
oFF
on
0.0
0.0
PE
0.0
LoC