INTELLIPRESS
™
ELECTRIC BENCH TOP PRESS
User Manual
BIM-IEBTPM-1218 Rev 1 | For Technical Assistance: 800-442-4622
17
See Figure 13: Operator Run Screen
This section will explain how to interpret the Press Status messages, reset the Run Count, and troubleshoot
the press in the event of an error/fault. For this section, refer to the Operator Run Screen (Figure 13).
SECTION 4: PRESS STATUS, RUN COUNT, AND ERROR RESET
The press has three status indications:
•
Ready
- A bold
READY
signal indicates the press is ready for the next input.
»
Any input to the press (Home Position, Start Signal, Stop, E-Stop, etc.) will be executed.
•
Running
- A bold
RUNNING
signal indicates the press is currently performing an operation.
»
Any additional input to the press while the press is in a RUNNING state other than the Stop icon
will cause fault to the press.
•
E-STOP
- A bold
E-STOP
signal indicates the E-Stop button has been depressed.
»
The press will not function until the E-STOP button has been reset.
SECTION 4.1: STATUS
SECTION 4.2: RUN COUNT
•
The
RUN COUNT
status keeps a running total of how many times the start signal has been energized.
»
The
RUN COUNT
can be reset by pressing the RESET RUN COUNT button.
SECTION 4.3: ERROR RESET
To recover from any error, follow the following steps:
•
If displayed, close the red Alarm error screen by selecting the red “X” in the upper right-hand corner of
the Alarm section.
»
Press the
STOP
icon.
»
Press the
ERROR RESET
button.
»
Press the
Home Position
button.
•
If the press still fails to return to the Home Position then please follow these instructions:
»
Press the
Error Reset
button again.
»
Press the
Home Position
button.