Quick Start Manual Rev 1.31
003X-608-133
Page 19
GROUP
(GRP)
ITEM
(ITM)
SELECT
(SEL)
EDIT
(EDT)
Underline = Defaults
OK
BUILD
DP
⊗
Decimal Point Position
000000, 00000.0, 0000.00, 000.000, 00.0000, 0.00000
Accept
CAP
⊗
Maximum Capacity
000100
to
999999
Default =
003000
<SEL>
changes position,
<EDT>
changes digit.
Accept
RES
⊗
Resolution
(Count-By)
1, 2, 5, 10, 20, 50, 100
Accept
GRADS
⊗
(K306 only)
Graduations 000100
to
030000
Default =
003000
<SEL>
changes position,
<EDT>
changes digit.
Accept
UNITS
⊗
Weighed Units
none, g, kg, lb, t
Accept
HI.RES
⊗
Resolution x 10 Mode
OFF, ON
Accept
CABLE
⊗
4-Wire or 6-Wire
4, 6 Accept
OPTION USE
⊗
Scale Use
INDUST, NSC, OIML, NTEP
Accept
FILTER
Reading Average
(time in seconds)
none, 0.2, 0.5, 1.0, 2.0, 3.0, 4.0
Accept
MOTION
⊗
Motion Detection
OFF, 0.5-1.0, 1.0-1.0
Default = 0.5 Graduations per Second
Accept
INIT.Z
Initial Zero on Startup
OFF, ON
Accept
Z.TRAC
⊗
Zero Tracking Sensitivity OFF,
SLOW (0.5 grads/sec),
FAST
(10 grads/sec)
Accept
Z.RANGE
⊗
Zero Operating Range
-2_ 2, -1_ 3, -20_20, FULL
Default = -2_ 2 (–2% to +2%)
Accept