background image

 

Page 2 of 10

 

 

PB_2005_2_GB_ZP5000

 

1. General 

Prior to start up, we recommend to read these operating instructions carefully as we do not assume any 
liability for damages and operating troubles which result from the nonobservance of these operating 
instructions! 
Any use beyond the applications described in these operating instructions is considered to be not in 
accordance with the product’s intended purposes. The manufacturer is not to be held responsilbe for any 
damages resulting from this: the user alone bears the corresponding risk.  
As to figures and indications in these operating instructions we reserve the right to make technical changes 
which might become necessary for improvements.  
The copyright on these operating instructions is kept reserved to the company DELIMON. These operating 
instructions are intended for the erecting, the operating and supervising personnel. They contain 
regulations and drawings of technical nature which must not – completely or partially - be distributed nor 
used nor communicated to others without authorization for competition purposes.  
 

 

Company address, spare parts and service address  

DELIMON GmbH 

Branch office 

Arminstraße 15 

Am Bockwald 4 

D-40277 Düsseldorf 

D-08344 Grünhain-Beierfeld 

Phone 

:  +49 211 77 74-0 

E-mail :  [email protected] 

Fax 

:  +49 211 77 74-210 

www.bijurdelimon.com 

 
 
 

2. Safety 

These operating instructions contain fundamental instructions which are to be observed  during erection, 
operation and maintenance. Therefore it is absolutely necessary for the fitter and the competent qualified 
staff/user to read  these operating instructions before installation and start-up. The operating instructions 
must be available at all times at the place of use of the machine/system.   
Not only the general safety instructions stated under this main point “safety“ are to be observed, but also  
the other specific safety instructions stated under the other main points.  

 

2.1 

Identification of safety warnings in the operating instructions 

The safety warnings contained in these operating instructions which, if not observed, may cause dangers 
to people,  are  specially marked with general danger symbols 

 

safety sign according to DIN 4844, warning about a danger spot ,  

in case of warning about electric voltage with  

 

safety sign according to DIN 4844, warning about dangerous electric voltage. 

In case of safety instructions which, if not observed, may cause damage to the machine and its function, 
the word 

 

ATTENTION

 

is inserted. 
Instructions that are directly attached to the machine, as for example  

 

rotational direction arrow 

 

identifications for fluid  connections 

must be observed at all events and maintained in a fully legible condition.  

 

 

Note: There is an increased skid risk in case of spilled/leaked out lubricants. They are to be removed 
at once properly.  

 

 
 

Safety sign according to DIN 4844, warning about skid risk.  

Содержание ZP5000

Страница 1: ...ump ZP5000 INDEX Page 1 General 2 2 Safety 2 4 A Pump type 4 B Number of outlets 4 C Inspection 4 D Kinds of drive 5 E Position of drive 5 F Reservoir 5 G Accessories 5 3 Application 5 4 Principle of operation 6 7 5 Specification 8 9 6 Start up 10 7 Plates 10 ...

Страница 2: ...om 2 Safety These operating instructions contain fundamental instructions which are to be observed during erection operation and maintenance Therefore it is absolutely necessary for the fitter and the competent qualified staff user to read these operating instructions before installation and start up The operating instructions must be available at all times at the place of use of the machine syste...

Страница 3: ...inst touch Protection against touch for moving parts e g coupling must not be removed when the machine is in operation Leakages e g from the shaft seal of hazardous goods to be delivered e g explosive toxic hot are to be removed in such a way that there is no danger to persons and environment Legal rules are to be ovserved Hazards caused by electrial power are to be excluded for details please ref...

Страница 4: ...nts are specified in the respective safety data sheets Used lubricants are hazardous forms of waste and therefore require special supervision in the sense of 41 paragraph 1 sentence 1 and paragraph 3 no 1 of KrW AbfG Closed Loop Waste Management Act Used oils must be handled in compliance with AltölV Waste Oil Ordinance The devices or components contaminated with lubricant must be disposed of by a...

Страница 5: ...tal 20 liters metal 30 liters metal G ACCESSORIES without Level switch A level switch is available for the indication of the filling level in the reservoir As sensor serves an ultrasonic sensor As soon as the min or max level allowed has been obtained a signal is released With the help of a signal lamp at the reservoir this signal can be used for the visual warning or for the control of an automat...

Страница 6: ...tons 6 and delived into the pressure bore 13 The scraper plate 14 is delivering the lubricant to the suction bores 15 The stirrer blade 16 pressing the lubricant through the sieve plate 17 into the suction compartment 18 is arranged in the lubricant reservoir 3 The central lubrication pump ZP5000 can be supplied with 1 or 2 pumping units 1 installed opposite to each other with a maximum of 8 outle...

Страница 7: ...Page 7 of 10 PB_2005_2_GB_ZP5000 4 Principle of operation continuation ...

Страница 8: ... delivery per outlet 0 0 2 cm stroke Pipe connection for feed line M 14 x 1 5 Step down ratio 150 1 300 1 420 1 225 1 Delivery rate 1 69 cm min 0 84 cm min 0 6 cm min 1 12 cm min Rated speed for pump shaft max 12 min 1 Rated speed 1360 min 1 Drive power 0 18 kW NLGI class 000 3 Temperature range 30 to 60 C Number of outlets max 16 Reservoir capacity 5 ltr 10 ltr 20 ltr 30 ltr Weight 21 and or 24 k...

Страница 9: ...Page 9 of 10 PB_2005_2_GB_ZP5000 5 Specification continuation ...

Страница 10: ... nipple A R1 8 DIN 71412 with the help of which this can be realized easily The pump with pumping mechanism one can also make filling by removing the blind flange It is absolutely essential to take care of cleanliness The pumping mechanisms are not self priming The higher is the consistency of the lubricant to be delivered the more disturbing are air inclusions in the pump case during commissionin...

Отзывы: