AS-i Safety Relay Output Module with Diagnostic Slave
1 EDM- and 2/1 safety inputs
Address Assignment
6.
Address Assignment
The device offers three different types of AS-i addresses:
6.1
Programming the AS-i address of the safety output
2.
Set desired address by using the hand-held addressing device or AS-i Mas-
ter.
3.
Check programmed address by using the hand-held addressing device or
AS-i Master.
4.
Check slave’s ID code by using the hand-held addressing device or AS-i
Master. The code should be set to “F”.
5.
Check slave’s ID1 code by using the hand-held addressing device or AS-i
Master. Code should be the same as the tens-digit of the address.
Safety output
BWU2236 monitors communication on the safety address and switches based on the
monitored data.
This address can only be programmed if the switches are set to ON /
PRG.
SEL
PRG
ON
RUN
Information!
The address must be tested as described in Section Programming the AS-i address of
the safety output.
Safety input slave
One safety input slave which monitors the two contacts S1 and S2.
This address can only be programmed if the switches are set to SEL /
PRG.
Diagnostic slave
One standard-AS-i-Slave (AB-Slave) for diagnostics and switching under normal
operating conditions.
This address can only be programmed if the switches are set to SEL /
RUN.
SEL
PRG
ON
RUN
SEL
PRG
ON
RUN
Basic position
Programming and monitoring of the address of the safety output is done
as described here:
1.
Set the switches of the device to ON/PRG.
SEL
PRG
ON
RUN
SEL
PRG
ON
RUN