July 2020
Installation, Operation and Maintenance Manual
MAN 573 Rev. 8
Figure 8
"RP" Pneumatic Actuators Coupling Dimensions - Overall Dimensions
Table 3.
Dimensions in mm
RP 13-14-15 49,5
49,5
M8
10
16
21
23
66
30
2,7 140
40
M6
4
RP 30
72,1
72,1
M10
12
22
29
25
92
32
2,7 164
50
M6
4
RP 60
88,4
88,4
M12
15
28
37
34
112
42
3,0 204
60
M6
4
RP 120
99,0
99,0
M16
23
37
49
45
132
55
3,0
270
75
M6
4
Both the actuator flanges can be used for valve coupling or the mounting of ancillary equipment
(positioner, limit switch box, etc.).
* UNI 3221
Actuator
Model
A
± 0,2
B
± 0,2
ØC
D
ØE ØF
G
ØH
K
J
L
ØM
ØN*
R
0
-0,1
0
-0,5
0
-0,2
+0,1
0
View from X
View from Y
№
4 threaded
holes
№
4 threaded
holes
Threaded hole ØN
Joint detail
Threaded hole ØN
X
Y
A
R
R
R
R
A
K
K
=
=
=
=
=
=
=
=
=
=
=
=
B
12
4
B
L
J
J
G
D
ØM
ØF
M6
ØE
ØH
ØC
ØC
ØE
+
0,5
0
Installation
10
Section 2: Installation