OLGAS-H
– High pressure spring return hydraulic actuator
Use and maintenance manual
© Copyright by BIFFI Italia. All right reserved.
Pag. 31
Contents may change without notice
3.6 CALIBRATION OF THE OPERATION TIME (IF
REQUIRED)
The calibration of the operation time is made by Biffi Italia S.r.L
according to customer requirements and to technical data-sheet
included in technical documentation. If necessary it’s possible to
modify or reset the operating time through two flow regulation valves
(optional) placed on inlets of hydraulic cylinder (see Picture 12 and
the applicable operating diagram).
Picture 12
– Adjustment of operating time by flow-regulator
valve (please refer to specific operating diagram, item 526-530)
To carry out the adjustment, operate the hand-wheel (turn clockwise
the hand-wheel to increase the operating time or turn the hand-wheel
counter-clockwise to decrease the operation time)