December 2021
Service Manual
MDE 252 Rev. 1
Troubleshooting
32
Section 2: Troubleshooting
2.17
Instruction to Disconnect C_GRID Connectors
The connector is made of two pieces, header and crimp housing. The header is welded
on the printed circuit board, the crimp housing is connected to wires. Due to mechanical
block, to disconnect the crimp housing from header can be difficult and could damage
connector or wires.
Figure 17
Header
Crimp housing
Mechanical block
Crimp housing
mechanical block
Disconnection between header and crimp housing can be helped by using a screwdriver.
By the screwdriver, force the mechanical block in the direction indicated in Figure 18 until
the crimp housing is free from header.
Direction to force
the mechanical block
Screwdriver
Figure 18