UPSI-1208DPx
Revision 2-0
12
D Technical Data
D1 General Technical Data
INPUT DATA
Unless otherwise stated, all specifications apply to 25 °C ambient temperature,
12 V DC input voltage and nominal output current (I
N
).
UPSI-1208DP2 / UPSI-1208DP3
Input voltage
12 V DC
Input voltage range
11.5 V DC…16 V DC
Electric strength max.
18 V DC
Fixed connect threshold
Undervoltage
Voltage drop Input/Output
11.5 V DC
0.6 V DC max. (depending on load)
Current consumption
I
N
(U
N
, I
OUT
= I
N
, I
CHARGE
= 0)
I
MAX
(U
N
, I
OUT
= I
N
, I
CHARGE
= max)
I
DYN
(U
N
, I
OUT
= I
DYN.BOOST
, I
CHARGE
= 0)*
I
NO-LOAD
(U
N
, I
OUT
= 0, I
CHARGE
= 0)
I
CHARGE
(U
N
, I
OUT
= 0, I
CHARGE
= max)
UPSI-1208DP2
8.1 A
9 A
8.1…10.1 A
<100 mA
3.5 A
UPSI-1208DP3
8.1 A
9 A
8.1…10.1 A
<100 mA
3.8 A
Power consumption
P
N
(U
N
, I
OUT
= I
N
, I
CHARGE
= 0)
P
MAX
(U
N
, I
OUT
= I
N
, I
CHARGE
= max)
I
DYN
(U
N
, I
OUT
= I
DYN.BOOST
, I
CHARGE
= 0)*
P
CHARGE
(U
N
, I
OUT
= 0, I
CHARGE
= max)
97 W
108 W
97…121 W
42 W
97 W
108 W
97…121 W
45.5 W
Internal input fuse
Yes (15 A)
Switch-on time
<5 s
Switch-on time battery start (BS)
n. a.
*Max. 58 sec., depending on output power (see for that „F12 Dynamic Powerboost“)