25
English
BP-LFP-1375
3. Technical data
BP-LFP-1375
Electrical data
Cell type
ANR26650M1-B
Nominal capacity
7.5 Ah
Nominal voltage
13.2 V
Energy
99 Wh
Voltage range Corepack
10 V – 14.4 V
Overvoltage shut-off
Once first cell reaches 3.8V
Undervoltage shut-off
Once first cell reaches 2.2 V
Undervoltage shut-off recovery
Single cell at 2.5 V
Undervoltage shut-off
(Shutdown mode)
Single cell at 2.5 V after 255 s
Short-circuit shut-off
66 A (< 1 µs)
Fuse
25 A ATO
Charging parameters
Charging-end-voltage
13.85 V
Recommended charging current
4 A
Shutdown by BMS
5 A (5.5 A for 5 s, 6 A for 2 s)
Operating temperature range
-20…+55
°
C
Shutdown temperature range
-30
°C (Recovery -27
°C) … +55
°C (Recovery 62
°C)
Discharge parameters
End-point voltage
8.8 V
Recommended discharge current 11 A
Shutdown by BMS
20 A (20.5 A for 6 s, 21 A for 1 s)
Operating temperature range
-30
°C…+55
°C
Shutdown temperature range
-30
°C (Recovery -27
°C) … +75
°C (Recovery 72
°C)
Mechanical data
Length
113 mm
Width
66 mm
Height
83 mm
Weight
980 g
Storage
Recommended temperature range 25
°C ±5 °C
Recommended charge level
80
%