54
English
UPSI-IP-1 series | UPSI- IP-2 series
21.2 Command Index “Sensors” 0x02
GetCPUTemperature() 0x00
This read function returns the cpu temperature.
Cmd
Name
Access
Type
Min.
Max
Unit
0x00
GetCPUTemperature()
R
Int32
0
+150
°C
Transfer packet: 0x01 0x03 0x02 0x00 0x04
GetOutputCurrent() 0x01
This read function returns the output current.
Cmd
Name
Access
Type
Min.
Max
Unit
0x01
GetOutputCurrent ()
R
Int32
0
+32768
mA
Transfer packet: 0x01 0x03 0x02 0x01 0x04
GetInputVoltage() 0x02 (not connected at moment)
This read function returns the input voltage.
Cmd
Name
Access
Type
Min.
Max
Unit
0x02
GetInputVoltage ()
R
Int32
0
+32768
mV
Transfer packet: 0x01 0x03 0x02 0x02 0x04
21.3 Command Index “Charge Controller” 0x03
GetEnergyStorageVoltage() 0x20
This read-word function returns the measured voltage of the capacitor 1.
Cmd
Name
Access
Type
Min.
Max
Unit
0x20 GetEnergyStorageVoltage ()
R
Int16
0
32768
mV
Transfer packet: 0x01 0x03 0x03 0x20 0x04