Translation of original operating manual for
machine-operated pneumatic drilling deburrer
OM no.: 001 580 511
12 of 13
Stand
24.05.2019
Abb. 9.
Switching on/off with push start
Models BE 309 R-2, BE 805 R-2,
BEW 309 R, BEW 309 R-1,
BEW 309 R SA, BEW 605 R,
BEW 605 R SA, BEW 606 R
These deburrer models are started and switched off
by means of an external valve.
Tool change
Caution!
Before changing the tool,
disconnect the drilling deburrer
from the compressed air supply
line!
Warning!
Never leave spanners or wrenches
attached to the tool!
Before starting the machine, check
that all spanners and wrenches
have been removed!
Models BE 309 R, BE 309 R-2, BE 805 R,
BE 805 R-2, BE 1005 R
Using the spanner supplied with the machine, hold the
spindle and open/close the chuck (right-hand thread)
(see Abb. 10).
Abb. 10.
Tool change in model BE
Models BEW 309 R,
BEW 309 R-1,
BEW 309 R SA, BEW 606 R
Using the spanner supplied with the machine, hold the
spindle and open/close the chuck (right-hand thread)
(see Abb. 11).
Abb. 11.
Tool change in model BEW
Model BEW 605 R, BEW 605 R SA
Using the spanner supplied with the machine, hold the
spindle and open/close the chuck (right-hand thread)
(see Abb. 12).
Abb. 12.
Tool change in model BEW 605 R,
BEW 605 R SA
Filter pressure reducer
The air supplied by a compressed air system is
generally contaminated and contains a considerable
amount of moisture. It is therefore advisable to install
a filter pressure reducer with a water trap between the
compressed air system and the machine. This reducer
controls the operating pressure and also filters and
dries the compressed air, significantly prolonging the
service life of the drilling deburrer.
For suitable filter pressure reducers, please refer to
our catalogue.
Maintenance
Caution!
Before performing any maintenance
work, disconnect the drilling
deburrer from the compressed air
supply line!
After use, clean the machine and check the tool for
wear. Always replace worn tools.
To ensure proper functioning of the drilling deburrer,
regularly inspect the maintenance unit. Drain off any
condensate and top up with BIAX special oil, if
necessary.
Inspect the damping and sintered plates in the rear
section of the housing and clean or replace them, if
necessary. To do this, disconnect the hose kit and the
threaded nipple (right-hand thread).
Inspection of filter pressure reducer
REMOVE
HOLD
OPEN
CLOSE
INSERT
CLOSE
OPEN
HOLD
OFF
ON