- 10 -
USE
APPLIANCE DESCRIPTION
1.4 LCD general features
For the boiler technical information refer to
the section "TECHNICAL INFORMATION"
on page 24.
Fig. 1.4
KEY
All symbols with lines radiat
-
ing from them indicate that the
symbol is flashing.
Stays on: D.H.W. function ena
-
bled.
Flashing: D.H.W. function in
progress.
Constantly illuminated: solar
control unit connected.
Flashing: solar pump operat
-
ing.
Stays on: heating function en
-
abled (winter).
Flashing: heating function in
progress.
Constantly illuminated: 3 star
preheating function active.
Flashing: 3 star preheating
function in progress.
Stays on: for 15s only after
system loading.
Flashing: in the case of low
system pressure or if viewing
the pressure from the INFO
menu.
Stays on: flame present
Flashing: drain upon ignition in
progress.
A
Stays on: maintenance due
pre-warning.
Flashing: maintenance re
-
quired or maintenance due.
b
Stays on: lockout error. The
boiler can be restarted by the
user, by pressing the reset but
-
ton.
Stays on: remote control con
-
nected.
Flashing: request from remote
control in progress.
SIGNAL DISPLAYED BY THE LCD
LCD
FUNCTION
E01 +
b
Safety lockout due to
failed ignition.
E02 +
b
Lockout due to safety
thermostat.
E03 +
b
Generic lockout.
E04 +
A
Pump circulation fail
-
ure, insufficient system
pressure or water pres
-
sure sensor not con-
nected.
E05 +
A
Control anomaly:
fan.
E06 +
A
NTC heating delivery
probe failure.
E07 +
A
D.H.W. NTC probe fail
-
ure / Hot water tank
sensor failure.