![Biasi M275V.2024 SM Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/biasi/m275v-2024-sm/m275v-2024-sm_service-manual_2748929033.webp)
- 33 -
GAS VALVE
lows .
7 Remove the brass plug and turn the plastic screw inside it
fully clockwise until it stops. Do not overtight.
8 Turn it counter-clockwise 2 and 3/4 turns.
9
Adjust the gas valve using the flue analyser as described
in section "11.3 Adjustment - Chimney Sweep Function" on
page 30.
After any service operation on the components of the gas
circuit check all the connections for gas leaks .
Warning: After cleaning or replacement as detailed
above, it is deemed necessary to undertake a com-
bustion analysis as detailed in section "11 .3 Adjust-
ment - Chimney Sweep Function" on page 30 .