![Biasi M275V.2024 SM Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/biasi/m275v-2024-sm/m275v-2024-sm_service-manual_2748929016.webp)
- 16 -
D.H.W. HEAT EXCHANGER
6 D .H .W . HEAT EXCHANGER
6 .1 Function
The D.H.W. heat exchanger "1" in Figure 6.1 and Figure 6.3 al-
lows the instantaneous transfer of heat from the primary hydrau-
lic circuit to the water destined for D.H.W. use.
Figure 6 .1
1
The schematic structure is shown in Figure 6.2.
Figure 6 .2
Primary hydraulic circuit
Domestic hot water circuit
6 .2 Removal
Warning: isolate the boiler from the mains electrici-
ty supply before removing any covering or compo-
nent .
1 Remove the panels of the case.
2 Empty the primary circuit and the D.H.W. circuit of the boiler.
3 Remove the control panel following the instructions from 4 in
section 2.3.
4 Remove main electronic p.c.b. box following the instructions
from 5 in section 2.4.
5 Completely unscrew the Allen key screws "2" in Figure 6.3
which hold the exchanger to the groups.
Figure 6 .3
2
1
2
6 Move the exchanger towards the rear of the boiler and extract
it to the left.
Reassemble the D.H.W. heat exchanger carrying out the remov-
al operations in the reverse order.
Warning: to lubricate the O-ring gaskets exclusively
use a silicone base grease compatible to be in con-
tact with foods and approved by the local water Au-
thorities .
Warning: When reassembling the exchanger be
sure to put the off center location/securing pin indi-
cated in Figure 6 .4 towards the left side of the boiler .
Figure 6 .4
Содержание M275V.2024 SM
Страница 2: ......
Страница 49: ...49 SHORT SPARE PARTS LIST 6 2 3 4 7 8 10 9 11 12 18 19 20 13 14 15 16 17 1 5 Figure 21 1...
Страница 50: ...50 NOTE...