- 76 -
MAINTENANCE
MAINTENANCE
9.7 Checking
the
fl ue expulsion
pipe
Have the integrity of the fl ue outlet pipe air
intake pipe, checked periodically, at least
once a year. For all the above maintenance
operations it is advisable to call an approved
Service Engineer.
9.8
Combustion analysis check
It is recommended that a combustion analy-
sis check is made. Remove the plug as in-
dicated in Fig. 9.7 and carry out combustion
analysis check and adjustment if necessary
as described in the section Gas valve - Ad-
justment of the Service manual.
Fig. 9.7
Flue analysis
points
9.9
Checking the condensate
drain pipe
The condensate drain pipe
25 ( Fig. 9.8
)
does not require any particular mainte-
nance but just check:
• That no solid deposits have formed, if so
remove them.
• That the condensate drain piping is not
clogged.
Unscrew the plug to clean inside the pipe.
Fig. 9.8
25
R
Removal
• Unscrew the screws
T and remove the
plate S ( Fig. 9.9 ).
• Remove the forks R and remove the con-
densate trap 25 moving it downwards ( Fig.
9.8 ).
Fig. 9.9
S
T
9.10 Visual inspection of appliance
Visually inspect all water joints, seals and
connections for any evidence of leakage
and retighten, grease or replace them as
necessary.