- 64 -
INST
ALLA
TION
COMMISSIONING
Programming using the REMOTE con-
trol
• Press button for more than 3 seconds to
enter in
mode ( Fig. 7.28 ).
Fig. 7.28
0
2
1
8
1
21
1 5
6
3
9
• Press buttons
and
at the same
time to enter transparent programming
( Fig. 7.29 ).
Fig. 7.29
• Press buttons
or
to display
the
"PM11"
program of the pump post-
circulation ( Fig. 7.30 ).
Fig. 7.30
• To modify the programmed SET, act on
buttons
or
and wait for the
programmed number to fl ash ( Fig. 7.31 ).
Each step increased or decreased corre-
sponds to 1 second.
Fig. 7.31
• To exit programming, press button .
7.12 Selecting the reignition fre-
quency
When the boiler functions in normal on/off
heating mode, the minimum time between
two ignitions is set at three minutes (re-igni-
tion frequency).
This time can be changed by a minimum of
zero to a maximum of eight and a half min-
utes by acting on programming both from
the panel controls and the remote control.
• Enter the "programming mode" by press-
ing keys 9 - 10 - 11 ( Fig. 7.32 ) for 10 sec-
onds at the same time until the letters
Pr
that alternate with code
01
are displayed
on the LCD display, indicating that "pa-
rameter 01"( Fig. 7.33 ) has been activated.