background image

4 - Inactive 

These ports are inactive at this time. 

5 - Inactive 

This port is inactive at this time 

NOTE 

Connection of external devices to inactive ports is not required or recommended. 

6 - Device ID 

The rotary ID switches give the unit a unique Device ID. The switches are in hexadecimal format. All units 
of the same device type must have a unique Device ID to function properly within a Vocia Paging World. 
The Factory Default Device ID is 01. A Device ID of 00 is invalid and cannot be used. 

To assign a Device ID of hex 07, leave the MSB switch on 0 and turn the LSB switch to 7. Device ID 
switches should be set using a 0.1 inch (2.5mm) to 0.12 inch (3.0mm) flat blade screwdriver. More 
information on setting IDs and the hexadecimal numbering scheme can be found in the Vocia Help File. 

 

NOTE 

Changes made to the Device ID while connected to the network require a power cycle in order to take effect. 

 