background image

MS-1e Rear 

 

1 - AC Power Entrance (IEC) 

The IEC power entrance provides for connection of the appropriate power cord (included with unit). An 
internal universal switching power supply accepts 100~240VAC @ 50/60Hz, with a maximum power 
consumption of 350 watts. 

CAUTION 

Do not remove or defeat the ground prong on the power cord, as this will constitute a shock hazard. Equipment should be 

connected to a mains socket outlet with a protective earthing connection. This plug is the main disconnecting device and should 

remain readily operable. There are no user interchangeable parts. Please contact Biamp Technical Support or your local distributor 

for all service requirements. 

2 - RS-232 Port 

This port is used to support console access to the MS-1e. This enables third party access to the Vocia 
MS-VTP (Vocia Text Protocol) API. Please refer to the seperate VTP programmers document or the 
software help file for more details. 

3 - Network Connection 

The MS-1e has four RJ45 Ethernet connectors located on the rear panel (Control, CobraNet, VoIP, and 
Live Interworld Streaming). Each connector has two green LEDs, which display Ethernet Link (left LED) 
and Activity (right LED).  

LAN-1 Connector (Control) 

This port connects the MS-1e to the Ethernet control network. This should be separate to the LAN that is 
being used by the CobraNet port either physically or through the use of managed switches and VLANs. 
The MS-1e can be configured in the Vocia software interface via this port, and as such it should be 
connected to the same network as the configuration PC during set up. This connection supports 
Interworld paging and communications. The default IP address of the MS-1e is 192.168.1.101. 

LAN-2 Connector (CobraNet) 

This port is used to communicate with non-server Vocia devices and as such should be connected to the 
same network as the local Vocia system. The data from the CobraNet network should be placed on its 
own LAN, either physically or through the use of managed switches and VLANs. Unlike other Vocia 
devices, the MS-1e physical network port does not display LED indication of CobraNet status. By default 
the MS-1e takes on the role of CobraNet conductor (time sync master). 

LAN-3 Connector (VoIP) 

This port is used to host VoIP paging functionality for the MS-1e. MS-1e VoIP paging is enabled at the 
World level. Connection should be made to the same network as other VoIP infrastructure within the 
facility. If Live Interworld Streaming is enabled (LAN 4) MS-1e VoIP paging functionality (LAN 3) will be 
disabled at the Universe level. 

LAN-4 Connector (Interworld) 

This port is used for Live Interworld Streaming. Live Interworld Streaming is enabled at the Universe level. 
The fourth network interface (LAN-4) on every MS-1e in the Universe will need to be configured with an 
IP address, subnet mask and optional gateway. This configuration requires the MS-1e hardware to be 
physically connected on the LAN-4 Network Interface port to a LAN or WAN with a valid connection to the 
other Worlds. If MS-1e VoIP paging is enabled Live Interworld streaming (LAN-4) will be disabled at the 
Universe level. 