CONNECTIONS AND CONTROLS

Power input port

Connect the Sierra II to the supplied AC power adaptor using  
the supplied 2 pole screw block terminal. White/black wire  
connects to 12V, black wire connects to GND.

The Sierra II adaptor incorporates a universal mains input which  
accepts AC line input from 100 V to 240 V.

Note: If using the PoE functionality to power the Sierra II, do not 
connect the AC power adaptor

I/O ports

The three I/O (Inputs/Outputs) can be configured as either output 
or input. Each is available for connection to a PIR (movement) sen-
sor, keyboard lock, relays or for other compatible uses. The ports
are not potential free; you may need external relays to prevent 
ground loops depending on your application.

When used as outputs, the I/O ports are active low.  
When activated, the I/O ports are tied to GND through a FET tran-
sistor (also called open drain/collector function).  
Each I/O can draw up to 24VDC/500mA.

When used as inputs, the applied voltage must be below 1 VDC  
to be accepted as LOW, and above 4 VDC (but below 24 VDC)  
to be accepted as HIGH. The inputs are default HIGH and must  
be connected to ground in order to change state.

RS-232/IR ports

The RS-232 ports (TX-1, RX-1, TX-2, TX-3) are used for one- or two-
way communication. Port 1 is a two way port, which can be used for 
devices for which a reply function is required, such as a projector.

All of the RS-232/IR ports can be configured in the Biamp Project 
Designer software either as RS-232 or as IR emitter.

LAN

GND
+12V

RX-1
TX-1
GND

TX-2
TX-3

I/O 3
I/O 2
I/O 1
GND
GND
NCL
NDA

RoHS

PIN 2 <-> Tx
PIN 3 <-> Rx

PIN 5 <-> GND

LAN

GND

12V

X-1
X-1

GND

X-2

I/O 3
I/O 2
I/O 1
GND

 
GND
NCL

LAN

GND
+12V

RX-1
TX-1
GND

TX-2

I/O 3
I/O 2
I/O 1
GND

 
GND
NCL

Содержание IMPERA SIERRA II

Страница 1: ...power source receptacle wall plug Power cords should be routed so that they are not likely to be stepped on or pinched by items placed upon or against them Do not defeat the safety purpose of a polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided ...

Страница 2: ...igital device pursuant to part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation The Class A limits are designed to provide reasonable protection against harmful interfer ence when the equipment is operated in a commer...

Страница 3: ...classroom meeting or conference room and is easy to install Sierra II can control devices through IR RS232 or even LAN Sierra II is available in polar white and anthracite The drawings in the manual of Biamp Impera Sierra II is based on the DK US and EU versions Function description RS 232 Tx Rx IR controls up to 2 IR devices on each port 1 RS 232 Tx IR controls up to 2 IR devices on each port 2 L...

Страница 4: ...nput trigger high 4VDC Output type Open drain Isolated output No Max voltage load 24 VDC Max current 0 5 A Connector 4 pin screw block Network LAN Speed 10 100 Mbit Duplex modes Half or Full DHCP Default off Default IP 192 168 254 252 Default gateway 192 168 1 1 Default subnet mask 255 255 255 0 Power over Ethernet Compliance 802 3af 802 3at 802 3af mode A B PD Class 1 General Width EU mm 437 mm 4...

Страница 5: ... button description 4 Mini USB for programming behind front cover Number Description 1 1 x 12 VDC power input 2 1 x RS 232 port Bidirectional or IR Unidirectional 3 2 x RS 232 or IR ports Unidirectional 4 1 x RJ 45 Network LAN connector with PoE functionality 5 3 x Digital Input Output 6 1 x NEB bus port 1 1 1 1 2 2 2 5 5 5 4 4 4 3 3 3 6 6 6 1 2 2 3 4 LAN GND I O 1 I O 2 I O 3 PWR NDA NCL GND 12V ...

Страница 6: ... bracket See different versions below 4 Connect and apply power to the control system 5 Configure the control system using the Biamp Project Designer DK version Insert a flathead screwdriver gently and pry out the front cover Remove the front cover and the paper label behind it Insert a flathead screwdriver into the button Gently push and pry out the button Insert the control system in a frame mat...

Страница 7: ...showing the button functions and mount the front cover Note that the front cover mounts in only one direction EU version Insert a flathead screwdriver gently and pry out the front cover Remove the front cover and the paper label behind it Insert the control system in a frame matching the back box used Insert screws matching the back box or bracket into the two holes Secure the control system to th...

Страница 8: ...r application When used as outputs the I O ports are active low When activated the I O ports are tied to GND through a FET tran sistor also called open drain collector function Each I O can draw up to 24VDC 500mA When used as inputs the applied voltage must be below 1 VDC to be accepted as LOW and above 4 VDC but below 24 VDC to be accepted as HIGH The inputs are default HIGH and must be connected...

Страница 9: ...itional cable length is needed in your application please use the NEB extender to allow placement of the devices up to 40 meters from the Sierra II See the Biamp website for details on the NEB Extender Connect the port as shown below When used as RS 232 transmit port Connect the device to TX 1 and GND as shown above When used as single IR port Connect the IR emitter to TX 2 striped wire and GND as...

Страница 10: ...roper activation Also each button has an embedded multicolor LED light to indicate cur rent status of the AV system Button function and LED indication are set up using the Biamp Project Designer software Configuration through USB port The USB port is used exclusively for configuring the Sierra II from the Biamp Project Designer software It can t be used to control any external devices The front pa...

Страница 11: ...g the power on again 1 2 3 4 Off Off Off Flashing No contact to Biamp extension unit Check to confirm that the serial number used in Project Designer matches the Biamp extension unit Check the network or RS 232 connection from the control system to the Biamp extension unit 1 2 3 4 Off Off Off Flashing Wrong firmware version in Biamp extension unit The Biamp extension unit has a different firmware ...

Страница 12: ...of Biamp All rights are reserved No third party is allowed access to content information or data in this manual without Biamp express written consent CHANGES Biamp reserve the right to change the specification and functions of this product without prior notice Questions AFTER reading this manual can be addressed to the local distributor or Biamp 9300 S W Gemini Drive Beaverton OR 97008 USA by mail...

Отзывы: