Safety Instructions and Warnings 

 

 

7

Safety Instructions and Warnings 

The equipment must be used in accordance 
with these safety instructions. 

Anyone using the equipment must also have 
read and understood the instructions in this 
manual or serious injury may result. 

If there is anything you are not sure about, 
contact your local BHM Medical 
representative. 

WARNING:

 

Only manufacturer designated 

parts designed for the purpose must be 
used for the Ministand™, in order to avoid 
injuries attributable to the use of inadequate 
parts. 

 

WARNING: Unauthorized modifications or 
repairs on the Ministand™ may affect its 
safety and invalidate any warranty. The 
manufacturer will not accept responsibility 
for any accidents, incidents or lack of 
performance that occur as a result of any 
such unauthorized modification or repair. 

 

General Instructions 

Keep the “Safety Instructions” with the floor 
lift at all times. 

Read the 

Instructions for Use

 in this manual 

before installing, operating or servicing this 
equipment. 

 

WARNING: BHM Medical mobile floor lifts 
are specifically designed for BHM Medical 
slings and accessories. Slings and 
accessories designed by any other 
manufacturer are prohibited and will void 
BHM Medical’s warranty. Use only BHM 
Medical slings and accessories to maintain 
patient’s safety and product utility. 

 

General 

 

Always carry out the “Before Every Use” 
inspection checklist prior to transferring a 
patient. 

 

This mobile patient lift must be operated 
by a trained attendant. Do not attempt to 
use the lift if you have not been properly 

trained to do so. This patient lift should 
never be used by patients on their own.  

 

Never use a damaged, torn or frayed sling. 

 

Do not use a sling that is not 
recommended for the lift 

 

This mobile floor lift is intended to be 
used for patients within the specified 
weight limit indicated for the lift. Do not 
lift more than the weight limit indicated. 

 

Follow lifting procedures outlined in this 
manual. 

 

Never leave a patient unsupervised during 
a transfer. 

 

Always place the sling around patient 
according to the sling instructions. 

 

Always maneuver the lift by using the 
handles located on the mast. If necessary, 
initiate the movement by pushing on the 
back of the base with your foot. Never 
push on the legs. 

 

Do not attempt to maneuver the lift by 
pushing on the mast, motor shaft, boom or 
patient. 

 

Do not use, in any way, the actuator as a 
handle to push or pull the lift. If the 
actuator is used as a handle, attendant and 
patient safety is greatly compromised. 

 

Replace any precautionary or instruction 
labels that cannot be easily read.  

 

Do not store the lift in a shower, bath or 
other area with high humidity. 

 

Do not use an electric lift in a shower. 

 

Your lift is for transferring patients only. 
Do not use the lift for any other purpose. 

 

Do not attempt to push or pull a loaded lift 
over a floor obstruction which the castors 
are unable to ride over easily, including 
steps, door thresholds or moving sidewalk. 

 

This mobile floor lift is not intended to be 
used on an inclined surface. 

Содержание Ministand

Страница 1: ...001 20075 EN rev 6 September 2010 Ministand Instructions for Use...

Страница 2: ...e patented or patent pending Our policy is one of continuous development and we therefore reserve the right to make technical alterations without notice The content of this publication may not be copi...

Страница 3: ...10 Operating the Ministand 11 Introduction 11 Adjusting the Width of the Legs 11 Power Base Models 12 Correct Use of the Brakes 12 Brakes application and release 12 Emergency Shut Off 12 Battery Pack...

Страница 4: ...t to avoid injuries that can be attributed to the use of inadequate parts only parts designated by BHM Medical should be used on equipment and other appliances supplied by BHM Medical Furthermore unau...

Страница 5: ...n this manual The Ministand must always be handled by a trained caregiver who must attend the patient during lift application and operation and in accordance with the instructions outlined in this Ins...

Страница 6: ...age of the equipment concerned Consumables must be maintained in accordance with published Instructions for Use and the Preventive Maintenance Schedule Equipment Identification The unit s identificati...

Страница 7: ...nufacturer This symbol is accompanied by the product s serial number of the manufacturer This symbol indicates separate collection for all batteries as per the WEEE Directive The black bar indicates t...

Страница 8: ...atient This mobile patient lift must be operated by a trained attendant Do not attempt to use the lift if you have not been properly trained to do so This patient lift should never be used by patients...

Страница 9: ...ry If the maximum load differs between hoist spreader bar and body support unit i e sling then the lowest maximum load must always be used Electric Shock Prevention Read the battery and charger instru...

Страница 10: ...Waste of Electronic and Electrical Components as well as local laws and regulations must be followed If not they may explode leak and cause personal injury When returning batteries insulate their ter...

Страница 11: ...10 Sling Compatibility For more information about sling use please refer to the documentation that comes with your sling Chest sling 4001C 4001 Total Transfer sling 4000TTC 4000TT Band sling TST X Hy...

Страница 12: ...the legs or push it to the far right to open the legs Fig 4 Pedal base The adjustments are made by changing the position of the pedal Press down on the left side of the pedal to close the legs Press d...

Страница 13: ...f the unit has to be halted while moving a patient Upon stationing the lift in front of the patient before the patient places his her feet onto the footrest Brakes application and release To apply bra...

Страница 14: ...d one second battery pack not included from the wall mounted charging unit not included Fig 11 Figure 11 NOTE to ensure long battery life charge for a minimum of 8 hours before using the lift for the...

Страница 15: ...cated on the control box attached to the mast These controls serve two functions They are secondary controls in the event the hand control stops functioning or if two attendants are involved in the tr...

Страница 16: ...e sling are correctly installed in the hook Fig 18 If they are not install the loop properly before lifting the patient Figure 18 Ensure the patient s arms are over the sling and that the sling is not...

Страница 17: ...in the sling during the transfer 7 Move the patient directly over the point of transfer and lock the wheels on the wheelchair or bed When the patient is positioned against the chair or bed lock the re...

Страница 18: ...ith electrical components or internal corrosion If a hot air dryer is used to dry the lift the temperature must not exceed 80 C 176 F Do not use petroleum based solvents or similar since this may dama...

Страница 19: ...removed it is imperative that you reinstall all associated safety devices such as cotter pins split rings and lock nuts If one of these devices is defective you must replace it with an original new co...

Страница 20: ...en operating the lift Ensure that the footrest is correctly attached to the mast Ensure that the kneepad is in the proper position for the patient Ensure that the kneepad is tightened If the product d...

Страница 21: ...TY CHARGER TROUBLE CHECK POWER ON LIGHT ON CHARGER IS NOT LIT CHECK CHARGER IS PLUGGED INTO WALL RECEPTACLE CHARGER IS PLUGGED IN BUT POWER ON LIGHT IS NOT LIT CHECK THAT ELECTRICAL OUTLET HAS POWER Y...

Страница 22: ...h IEC 60601 1 WARNING Radio transmitting devices such as mobile telephones two way radios etc should never be used near the Ministand since they can interfere with the function of the lift Cables from...

Страница 23: ...Technical Specifications 22 Figure 22...

Страница 24: ...r this warranty to be valid the purchaser must present its original proof of purchase at the moment of the claim The defective unit assembly or part must be returned to BHM Medical for inspection The...

Страница 25: ...nces shall BHM Medical be liable for consequential incidental or special damages arising in connection with use or inability to use the products In no event shall BHM Medical s liability for breach of...

Страница 26: ...001 20075 EN rev 6 September 2010...

Отзывы: