BGS technic KG
Bandwirkerstr. 3
D-42929 Wermelskirchen
Tel.: 02196 720480
Fax.: 02196 7204820
www.bgstechnic.com
© BGS technic KG, Copying and further use not allowed
CONTINUITY TEST
1. Connect the red test lead to "VmA
Ω
" jack and the black test lead to "COM" jack.
2. Set the Function/Range switch to " •)))" range.
3. Connect the test leads to the two terminals of the circuit to be tested. If the resistance is lower
than about 20
Ω
, the built-in buzzer will sound.
Note
: To avoid electric shock to you or damage to the meter, disconnect circuit power and discharge
all capacitors before continuity test.
SIGNAL OUTPUT
1. Set the Function/Range switch to"
" range.
2. A test Signal will be Output between "VmA
Ω
" and "COM" jacks, the Output voltage is approx. 3V
p-p 50Hz.
Note
: This area is used as a signal output. Do not use other signals on these terminals.
MAINTENANCE
Before opening the case, always disconnect the test leads from all live circuits. To continue protection
against fire, replace fuse only with the specified voltage and current ratings: F 250mA / 250V (Fast
Blown), 05 x 20mm c Periodically wipe the case with a damp cloth and mild detergent. Do not use
abrasives or solvents.
BATTERY AND FUSE REPLACEMENT
If"
"appears on the LCD, it indicates that the battery should be replaced. To replace the battery,
remove the screws on the back cover, and replace the exhausted battery with a new one of the same
ratings. Reinstall the back cover and the screws. Fuse rarely needs replacement and is blown
generally as a result of operator's error. To replace the fuse (300V/F250mA) / (300V/F10A), remove
the screws on the bottom of the case, simply remove the old one, and replace it with a new one of the
same ratings. Reinstall the back cover and the screws.
ACCESSORIES
Manual: 1 piece
Test leads: 1 pair
ENVIRONMENTAL PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and
packaging should be sorted, taken to a recycling centre and disposed of in a manner which is
compatible with the environment.
DISPOSAL
Do not dispose battery in household waste.
Batteries should be disposed of in a responsible manner, they must be disposed at
appropriate collection point.
Dispose of this product at the end of its working life in compliance with the EU Directive on
Waste Electrical and Electronic Equipment. Contact your local solid waste authority for
recycling information or give the product for disposal to BGS technic KG or to an electrical
appliances retailer.