16
5. Electrical wiring
Airflow performance data is based on cooling performance with a coil and no filter in place.
Select performance table for appropriate unit size external static applied to unit allows
operation within the minimum and maximum limits shown in table below for both cooling
and electric heat operation.
24
36
NUMBER
MODEL
MOTOR
SPEED
External Static Pressure-Inches W.C.[kPa]
CFM(Watts)
0
[0]
0.1
[.02]
0.16
[.04]
0.2
[.05]
0.3
[.07]
0.4
[.10]
0.5
[.12]
0.6
[.15]
0.7
[.17]
0.8
[.20]
LOW
LOW
MIDDLE
MIDDLE
HIGH
HIGH
CFM
RPM
Watts
Amps
CFM
RPM
Watts
Amps
CFM
RPM
Watts
Amps
CFM
RPM
Watts
Amps
CFM
RPM
Watts
Amps
CFM
RPM
Watts
Amps
695
585
153
0.71
844
680
178
0.81
935
760
220
1.00
1261
755
290
1.32
1394
815
304
1.39
1484
860
352
1.6
658
644
146
0.68
804
723
172
0.78
901
790
214
0.98
1186
778
277
1.26
1311
833
293
1.33
1403
873
341
1.54
618
688
139
0.65
761
759
166
0.76
853
815
208
0.95
1114
801
264
1.21
1229
851
282
1.28
1315
885
328
1.49
606
700
137
0.65
749
768
164
0.75
839
821
205
0.94
1039
819
254
1.16
1158
865
271
1.23
1245
895
319
1.45
560
756
130
0.62
679
813
154
0.71
760
852
194
0.90
1022
824
251
1.15
1142
869
270
1.22
1220
898
315
1.38
490
802
120
0.59
620
858
147
0.69
691
881
184
0.86
919
827
236
1.08
1033
887
257
1.17
1123
910
303
1.38
392
853
109
0.55
516
900
137
0.64
583
913
171
0.81
798
860
216
1.00
902
905
241
1.10
988
923
228
1.04
242
920
92
0.49
359
950
123
0.59
456
935
159
0.76
527
883
182
0.86
630
923
210
0.95
685
944
250
1.14
-
-
-
-
-
-
-
-
169
980
133
0.65
280
938
157
0.75
362
950
182
0.84
420
955
222
1.01
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
243
970
208
0.95