background image

 
 
 

BGO30B/50B/60B/80B; BGO70A/100A

   

Instruction Manual 

 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

Direct and Indirect-fired   
Diesel/Kerosene Heaters 

 

 

 
 

BGO-30B      Indirect-fired 
BGO-50B      Indirect-fired 
BGO-60B      Indirect-fired 
BGO-80B      Indirect-fired 
BGO-70A      Direct-fired 
BGO-100A    Direct-fired 

 

Содержание BGO100A

Страница 1: ...B BGO70A 100A Instruction Manual Direct and Indirect fired Diesel Kerosene Heaters BGO 30B Indirect fired BGO 50B Indirect fired BGO 60B Indirect fired BGO 80B Indirect fired BGO 70A Direct fired BGO...

Страница 2: ...arranty or representation for any particular purposes The information is offered in good faith and with the understanding that any use of the units or accessories in breach of the directions and warni...

Страница 3: ...MAY CAUSE CARBON MONOXIDE CO POISONING WHEN INCORRECTLY USED E G INDOORS WITHOUT ADEQUATE AIR CIRCULATION OR IF NOT PROPERLY WORKING CO POISONING MAY LEAD TO DEATH GENERAL HAZARD WARNING FAILURE TO C...

Страница 4: ...V 50Hz Electrical Power Motor 250W 750W 750W 750W 430W 430W Pump Pressure Setting bar 10 0 10 5 11 5 10 0 10 5 10 0 Current Rating A 1 5 3 2 3 2 3 3 2 6 2 6 Fuse Rating T3 15A T3 15A T3 15A T3 15A T3...

Страница 5: ...h airflow from outside must be ensured Direct fired heaters are intended for use in outdoor open areas or in indoor well ventilated areas For indoor use provide permanent ventilation openings of at le...

Страница 6: ...ct the heater to a chimney or to an exhaust duct To get a proper draught in the chimney the exhaust gas path must rise Avoid any elbows and bends in the first part of the exhaust ducts for at least 3...

Страница 7: ...he appliance with wet hands or when either the heater or the power cable is wet If the supply cable is damaged it must be replaced by the manufacturer by a service agent or a similar qualified person...

Страница 8: ...Fig 6 Fig 2 Extract the burner head Fig 3 Fig 3 Whirl disc Clean the whirl disc Fig 3 using a brush and then blow compressed air on it To get good combustion the air flow openings in the whirl disc sh...

Страница 9: ...ecrease the pressure Fig 6 Air collar adjustment Fig 7 The air collar position is factory set and must be checked and adjusted by qualified technicians only Tampering with the unit may be dangerous HI...

Страница 10: ...connections 8 Wiring Diagram 9 Troubleshooting PROBLEM CAUSE REMEDY Motor does not start E1 displayed on No power or low voltage Check power line and voltage Check fuse and replace if necessary Fault...

Страница 11: ...th 10 20 kerosene Heater starts but combustion is not good Insufficient airflow into combustion chamber Check air inlet fan motor and air collar position adjust it if necessary Wrong fuel pressure Che...