NETTUNO BLOWING is equipped also with blowing function for the ironing of delicate 
and light clothes. This function allows the garments to be ironed only with steam, as it 

lifts them from the board and avoids them from being pressed by the iron’s weight.  
 
 

8.

 

ELECTRICAL RISKS

 

 
The following situations are considered to be dangerous for the operator: 

 

1.

 

when the earth protector switch is activated; 

2.

 

using the ironing board during thunderstorms; 

3.

 

using  the  ironing  board  without  proper  protection  for  feet  (without  shoes…)  or 
with wet hands or feet; 

4.

 

using the ironing board with damaged electric cables; 

5.

 

using the ironing board when the electric cable touches hot parts of the machine; 

6.

 

when the machine is not connected to a good ground wire with observance of the 
law in force. 

 

 

9.

 

MECHANICAL RISKS

 

 
The following situations are considered to be dangerous for the operator: 
 

1.

 

using the ironing board for different purposes other than ironing. 

 
 

10.

 

THERMIC RISKS

 

 
The machine can become extremely hot: use it very carefully and disconnect the plug 

when not in use. 
It is recommended to proceed with the cleaning of the machine only when it is cold. 

 

 
11.

 

INTERVENTIONS AND SMALL REPAIRS

 

 

1.

 

It is recommended to replace the cover (Prontotop): 

-

 

 every 320 hrs. of operation or maximum every 3 months; 

-

 

 replace it also if the vacuum of the board in unsatisfactory or if stains appear on it. 

The stains can appear also if the operator uses too much steam and/or doesn’t use 
vacuum enough (in this case decrease the steam flow and use more vacuum). 
The replacement of the cover is to be done with the ironing board switched off and 

cold.

 

N.B.:

 the Prontotop can be washed 1 or 2 times. 

2.

 

Immediately replace the electric wire when it is damaged. The wire is supplied by 
the manufacturer or authorized service centres.  Do not use the equipment with a 

damaged electric wire. 

3.

 

Clean the air vacuum/exhaust duct, the fan of the vacuum/blowing motor and any 
air  intake  from  accumulations  of  dust  which  could  reduce  the  vacuum/blowing 

performance. 

 
 

 
 

Содержание BATTISTELLA NETTUNO

Страница 1: ...UNO MAXI BLOWING mod 2005 BATTISTELLA B G S r l Via Bessica 219 36028 Rossano Veneto VI ITALY 39 0424 549027 39 0424 549007 www battistellag it info battistellag it This manual is property of BATTISTE...

Страница 2: ...3 OPENING OF PACKAGE 3 4 CONNECTION 3 5 STARTING 4 6 GENERAL INSTRUCTIONS 4 7 IRONING OPERATION 4 8 ELECTRICAL RISKS 5 9 MECHANICAL RISKS 5 10 THERMIC RISKS 5 11 INTERVENTIONS AND SMALL REPAIRS 5 12...

Страница 3: ...UNO MAXI NETTUNO BLOWING NETTUNO MAXI BLOWING POWER SUPPLY 220 V 60 Hz 220 V 60 Hz 220 V 60 Hz 220 V 60 Hz TOTAL INSTALLED POWER 1400 W 1835 W 1566 W 2001 W BOARD POWER 800 W 800 W 800 W 800 W SUCTION...

Страница 4: ...for further consultation 2 Remove the ironing board from the box 3 Remove the protection film nylon from the metal iron rest 4 For models equipped with sleeve ironing arm fig 1 A insert the arm and fi...

Страница 5: ...before any maintenance or cleaning operation 8 Keep the electric wire away from hot surfaces and be careful not to crush it under doors or to step on it 9 Never use the ironing board without the cove...

Страница 6: ...for different purposes other than ironing 10 THERMIC RISKS The machine can become extremely hot use it very carefully and disconnect the plug when not in use It is recommended to proceed with the clea...

Страница 7: ...re failures or damages that do not derive from a manufacturing defect when there are damages deriving from a fortuitous event fire short circuit or due to third parties tampering when using the machin...

Страница 8: ...Exclusion of liability for indirect damage In no case Battistella B G S r l will be liable for damages including without limitation indirect damage due to loss or loss of earnings business interruptio...