ENGLISH

INSTALLATION MANUAL

INSTALLER WARNINGS

Anything that is not explicitly provided for in the installation ma-

nual is not allowed. The operator’s proper operation can only be 

guaranteed if the information given is complied with. The Firm shall 

not be answerable for damage caused by failure to comply with the 

instructions featured herein.

While we will not alter the product’s essential features, the Firm reserves 

the right, at any time, to make those changes deemed opportune to 

improve the product from a technical, design or commercial point of 

view, and will not be required to update this publication accordingly.

WARNING! Important safety instructions. Carefully read and comply with 

all the warnings and instructions that come with the product as incorrect 

installation can cause injury to people and animals and damage to property. 

The warnings and instructions give important information regarding safety, 

installation, use and maintenance. Keep hold of instructions so that you can 

attach them to the technical file and keep them handy for future reference.

GENERAL SAFETY

This product has been designed and built solely for the purpose indicated herein. 

Uses other than those indicated herein might cause damage to the product and 

create a hazard.

- The units making up the machine and its installation must meet the requirements

of the following European Directives, where applicable: 2004/108/EC, 2006/95/

EC, 2006/42/EC, 89/106/EC, 99/05/EC and later amendments. For all countries

outside the EEC, it is advisable to comply with the standards mentioned, in ad-

dition to any national standards in force, to achieve a good level of safety.

- The Manufacturer of this product (hereinafter referred to as the “Firm”) disclaims 

all responsibility resulting from improper use or any use other than that for

which the product has been designed, as indicated herein, as well as for failure 

to apply Good Practice in the construction of entry systems (doors, gates, etc.) 

and for deformation that could occur during use.

- Installation must be carried out by qualified personnel (professional installer,

according to EN 12635), in compliance with Good Practice and current code.

- Before installing the product, make all structural changes required to produce 

safety gaps and to provide protection from or isolate all crushing, shearing and 

dragging hazard areas and danger zones in general in accordance with the

provisions of standards EN 12604 and 12453 or any local installation standards. 

Check that the existing structure meets the necessary strength and stability

requirements.

- Before commencing installation, check the product for damage.

- The Firm is not responsible for failure to apply Good Practice in the construction 

and maintenance of the doors, gates, etc. to be motorized, or for deformation 

that might occur during use. 

- Make sure the stated temperature range is compatible with the site in which the 

automated system is due to be installed.

- Do not install this product in an explosive atmosphere: the presence of flammable

fumes or gas constitutes a serious safety hazard.

- Disconnect the electricity supply before performing any work on the system.

Also disconnect buffer batteries, if any are connected.

- Before connecting the power supply, make sure the product’s ratings match the 

mains ratings and that a suitable residual current circuit breaker and overcurrent 

protection device have been installed upline from the electrical system. Have

the automated system’s mains power supply fitted with a switch or omnipolar 

thermal-magnetic circuit breaker with a contact separation that provide full

disconnection under overvoltage category III conditions.

- Make sure that upline from the mains power supply there is a residual current 

circuit breaker that trips at no more than 0.03A as well as any other equipment 

required by code.

- Make sure the earth system has been installed correctly: earth all the metal parts 

belonging to the entry system (doors, gates, etc.) and all parts of the system

featuring an earth terminal.

- Installation must be carried out using safety devices and controls that meet

standards EN 12978 and EN 12453.

- Impact forces can be reduced by using deformable edges.

- In the event impact forces exceed the values laid down by the relevant standards, 

apply electro-sensitive or pressure-sensitive devices.

- Apply all safety devices (photocells, safety edges, etc.) required to keep the

area free of impact, crushing, dragging and shearing hazards. Bear in mind the 

standards and directives in force, Good Practice criteria, intended use, the instal-

lation environment, the operating logic of the system and forces generated by 

the automated system.

- Apply all signs required by current code to identify hazardous areas (residual

risks). All installations must be visibly identified in compliance with the provisions 

of standard EN 13241-1.

Once installation is complete, apply a nameplate featuring the door/gate’s data.

- This product cannot be installed on leaves incorporating doors (unless the motor 

can be activated only when the door is closed).

- If the automated system is installed at a height of less than 2.5 m or is accessible, 

the electrical and mechanical parts must be suitably protected.

- Install any fixed controls in a position where they will not cause a hazard, away 

from moving parts. More specifically, hold-to-run controls must be positioned 

within direct sight of the part being controlled and, unless they are key operated, 

must be installed at a height of at least 1.5 m and in a place where they cannot 

be reached by the public.

- Apply at least one warning light (flashing light) in a visible position, and also

attach a Warning sign to the structure. 

- Attach a label near the operating device, in a permanent fashion, with informa-

tion on how to operate the automated system’s manual release.

- Make sure that, during operation, mechanical risks are avoided or relevant

protective measures taken and, more specifically, that nothing can be banged, 

crushed, caught or cut between the part being operated and surrounding parts.

- Once installation is complete, make sure the motor automation settings are

correct and that the safety and release systems are working properly.

- Only use original spare parts for any maintenance or repair work. The Firm dis-

claims all responsibility for the correct operation and safety of the automated

system if parts from other manufacturers are used.

- Do not make any modifications to the automated system’s components unless 

explicitly authorized by the Firm.

- Instruct the system’s user on what residual risks may be encountered, on the

control systems that have been applied and on how to open the system manu-

ally in an emergency. give the user guide to the end user.

- Dispose of packaging materials (plastic, cardboard, polystyrene, etc.) in accord-

ance with the provisions of the laws in force. Keep nylon bags and polystyrene 

out of reach of children.

WIRING

WARNING! For connection to the mains power supply, use: a multicore cable with 

a cross-sectional area of at least 5x1.5mm

2

 or 4x1.5mm

2

 when dealing with three-

phase power supplies or 3x1.5mm

2

 for single-phase supplies (by way of example, 

type H05 VV-F cable can be used with a cross-sectional area of 4x1.5mm

2

). To con-

nect auxiliary equipment, use wires with a cross-sectional area of at least 0.5 mm

2

.

-  Only use pushbuttons with a capacity of 10A-250V or more.

-  Wires must be secured with additional fastening near the terminals (for example,

using cable clamps) in order to keep live parts well separated from safety extra 

low voltage parts.

-  During installation, the power cable must be stripped to allow the earth wire 

to be connected to the relevant terminal, while leaving the live wires as short 

as possible.  The earth wire must be the last to be pulled taut in the event the 

cable’s fastening device comes loose.

WARNING! safety extra low voltage wires must be kept physically separate from 

low voltage wires.

Only qualified personnel (professional installer) should be allowed to access 

live parts.

CHECKING THE AUTOMATED SYSTEM AND MAINTENANCE

Before the automated system is finally put into operation, and during maintenance 

work, perform the following checks meticulously:

- Make sure all components are fastened securely.

- Check starting and stopping operations in the case of manual control.

- Check the logic for normal or personalized operation.

- For sliding gates only: check that the rack and pinion mesh correctly with 2 mm 

of play along the full length of the rack; keep the track the gate slides on clean 

and free of debris at all times.

- For sliding gates and doors only: make sure the gate’s running track is straight 

and horizontal and that the wheels are strong enough to take the weight of the 

gate.

- For cantilever sliding gates only: make sure there is no dipping or swinging

during operation.

- For swing gates only: make sure the leaves’ axis of rotation is perfectly vertical.

-For barriers only: before opening the door, the spring must be decompressed

(vertical boom).

- Check that all safety devices (photocells, safety edges, etc.) are working properly 

and that the anti-crush safety device is set correctly, making sure that the force 

of impact measured at the points provided for by standard EN 12445 is lower

than the value laid down by standard EN 12453.

- Impact forces can be reduced by using deformable edges.

- Make sure that the emergency operation works, where this feature is provided.

- Check opening and closing operations with the control devices applied.

- Check that electrical connections and cabling are intact, making extra sure that 

insulating sheaths and cable glands are undamaged.

- While performing maintenance, clean the photocells’ optics.

- When the automated system is out of service for any length of time, activate the 

emergency release (see “EMERGENCY OPERATION” section) so that the operated 

part is made idle, thus allowing the gate to be opened and closed manually.

- If the power cord is damaged, it must be replaced by the manufacturer or their

technical assistance department or other such qualified person to avoid any risk .

- If “D” type devices are installed (as defined by EN12453), connect in unverified 

mode, foresee mandatory maintenance at least every six months

- The maintenance described above must be repeated at least once yearly or at

shorter intervals where site or installation conditions make this necessary.

WARNING! 

Remember that the drive is designed to make the gate/door easier to use and 

will not solve problems as a result of defective or poorly performed installation 

or lack of maintenance

 SCRAPPING

Materials must be disposed of in accordance with the regulations in 

force. Do not throw away your discarded equipment or used batteries 

with household waste. You are responsible for taking all your waste 

electrical and electronic equipment to a suitable recycling centre.

DISMANTLING

If the automated system is being dismantled in order to be reassembled at another 

site, you are required to:

- Cut off the power and disconnect the whole electrical system.

- Remove the actuator from the base it is mounted on.

- Remove all the installation’s components.

- See to the replacement of any components that cannot be removed or happen 

to be damaged.

THE DECLARATION OF CONFORMITY CAN bE vIEWED ON THIS WEbSITE: 

WWW.bFT.IT IN THE PRODUCT SECTION.

AVVERTENZE PER L’INSTALLATORE D811766_12

Содержание ZARA BTL2

Страница 1: ...NSTRUCCIONES DE INSTALACION INSTALLATIEVOORSCHRIFTEN Attenzione Leggere attentamente le Avvertenze all interno Caution Read Warnings inside carefully Attention Veuillez lire attentivement les Avertissements qui se trouvent à l intérieur Achtung Bitte lesen Sie aufmerksam die Hinweise im Inneren Atención Leer atentamente las Advertencias en el interior Let op Lees de Waarschuwingen tigre aan de bin...

Страница 2: ...ze Safety devices Sécurités Sicherheitsvorrichtungen Dispositivos de seguridad Veiligheden Collegamento di 1 coppia di fotocellule non verificate Connection of 1 pair of non tested photocells Connexion 1 paire photocellules no vérifiées Anschluss von einem Paar nicht überprüften Fotozellen Conexión de 1 par fotocélulas no comprobadas Aansluiting van 1 paar fotocellen anders dan trusted device Coma...

Страница 3: ...NBEDIENUNG MEMORIZACIÓN DEL RADIOMANDO MEMORIZAÇÃO DO RADIOCOMANDO LEGENDA KEY LÉGENDE LEGENDE LEYENDA LEGENDA Fisso Steadily lit Fixe Ununterbrochen an Fijo Continu Lampeggio continuo Continuous flashing Clignotement continu Kontinuierliches Blinken Parpadeo continuo Continu knipperen Lampeggio intermittente Intermittent flashing Clignotement intermittent intermittierendes Blinken Parpadeo interm...

Страница 4: ...1 1 2 1 2 3 4 5 TX2 RX2 1 PHOT 1 PHOT CL 1 PHOT 1 PHOT CL 2 PHOT 2 PHOT CL BAR 8K2 50 52 50 52 50 51 50 51 50 51 50 51 50 70 72 70 72 73 70 70 72 73 BAR Bar 1 1 2 3 4 5 6 Bar 1 1 2 3 4 5 Bar 2 1 2 3 4 5 Bar 1 1 2 3 4 5 6 6 6 Bar 1 1 2 3 4 5 6 Bar 1 1 2 3 4 5 Bar 2 1 2 3 4 5 Bar 1 1 2 3 4 5 6 6 6 BAR 8K2 1 BAR 1 BAR 2 BAR 51 51 50 51 50 51 50 52 52 52 74 70 74 70 75 74 70 51 50 70 75 70 74 8 2Kohm ...

Страница 5: ...Attenzione Fissareinmodopermanenteunaetichettarelativaalfunzionamentodellosblocco manuale dell automazione e apporla vicino all organo di manovra Assicurarsi che durante la manovra siano evitati o protetti i rischi meccanici ed inparticolarel impatto loschiacciamento ilconvogliamento ilcesoiamentotra parte guidata e parti circostanti Dopo aver eseguito l installazione assicurarsi che il settaggio ...

Страница 6: ...ilizzare cavo multipolare di sezione minima 3x1 5mm2 e del tipo previsto dalle normative vigenti Per il collegamento dei motori utilizzare cavo di sezione minima 1 5 mm2 e del tipo previsto dalle normative vigenti A titolo di esempio se il cavo è all esterno all aperto deve essere almeno pari a H07RN F mentre se all interno in canaletta deve essere almeno pari a H05 VV Morsetto Definizione Descriz...

Страница 7: ...l motore 1 SWC2 Acceso il finecorsa chiusura del motore 2 è libero Spento Attivazione ingresso finecorsa chiusura del motore 2 SWO2 Acceso il finecorsa apertura del motore 2 è libero Spento Attivazione ingresso finecorsa apertura del motore 1 ERR SPENTO nessun errore ACCESO vedi tabella diagostica errori RADIO VERDE Spento programmazione radio disattiva Lampeggiante solo led Radio Programmazione r...

Страница 8: ...sso per bordo resistivo 8K2 Il comando inverte il movimento per 2 sec OFF Ingresso configurato come Bar costa sensibile Fig H rif 3 4 Il comando inverte il movimento per 2 sec 3 Verifica ingresso fotocellula OFF ON Abilita la verifica delle sicurezze sull ingresso PHOT OFF Verifica delle sicurezze sull ingresso PHOT non abilitata 4 Verifica ingresso costa OFF ON Abilita la verifica delle sicurezze...

Страница 9: ...ast one warning light flashing light in a visible position and also attach a Warning sign to the structure Attach a label near the operating device in a permanent fashion with informa tion on how to operate the automated system s manual release Make sure that during operation mechanical risks are avoided or relevant protective measures taken and more specifically that nothing can be banged crushed...

Страница 10: ...ly use a multicore cable with a cross sectional area of at least 3x1 5mm2 of the kind provided for by the regulations in force To connect the motors use a cable with a cross sectional area of at least 1 5mm2 ofthekindprovidedforbytheregulationsinforce Bywayofexample if the cable is run outside unprotected it must be at least type H07RN F while if it is run inside in a raceway it must be at least t...

Страница 11: ...ut activated SWC2 Lit the limitswitch closing of motor 2 is free Unlit motor 2 closing limit switch input activated SWO2 Lit the limitswitch opening of motor 2 is free Unlit motor 2 opening limit switch input activated ERR Unlit no error LIT see error diagnostics table RADIO GREEN Unlit remote programming not active Radio LED only flashing Remote programming active waiting for hidden key Flashing ...

Страница 12: ...ig H ref 5 Input for resistive edge 8K2 The command reverses movement for 2 sec OFF Input configured as Bar safety edge Fig H ref 3 4 The command reverses movement for 2 sec 3 Photocell input check OFF ON Enable safety check on the PHOT input OFF Safety check on PHOT input not enabled 4 Edge input check OFF ON Enable safety check on the BAR input OFF Safety check on BAR input not enabled 5 Photoce...

Страница 13: ...originales pour les opérations d entretien ou les réparations Le Fabricant décline toute responsabilité quant à la sécurité et au bon fonctionnement de l automatisation en cas d utilisation de composants d autres Fabricants Ne modifier d aucune façon les composants de l automatisation sans l autorisa tion expresse du Fabricant Informer l utilisateur de l installation sur les risques résiduels éven...

Страница 14: ...n câble multipolaire ayant une section d au moins 3x1 5 mm2 et conforme aux normes en vigueur Pourlaconnexiondesmoteurs utilisezuncâblemultipolaireayantunesection d au moins 1 5 mm2 et conforme aux normes en vigueur A titre d exemple si le câble est à l extérieur en plein air il doit être au moins égal à H07RN F mais s il est à l intérieur dans une gaine il doit être au moins égal H05W F Borne Déf...

Страница 15: ...t Activation entrée fin de course fermeture du moteur 2 SWO2 Eclairé le fin de course d ouverture du moteur 1 est libre Eteint Activation entrée fin de course ouverture du moteur 2 ERR Eteint aucune erreur ÉCLAIRÉ cf tableau diagnostic erreurs RADIO VERT Eteint programmation radio désactive Clignotante uniquement Radio Programmation radio active at tente touche cachée Clignotante synchrone avec Le...

Страница 16: ... résistif 8K2 La commande invertit le mouvement pendant 2 secondes OFF Entrée configurée comme Bar linteau sensible Fig H réf 3 4 La commande invertit le mouvement pendant 2 secondes 3 Vérification sur l entrée cellule photoélectrique OFF ON Active la vérification des sécurités sur l entrée PHOT OFF Vérification des sécurités sur l entrée PHOT non activée 4 Vérification sur l entrée côté OFF ON Ac...

Страница 17: ...nungsgemäß blockieren Verwenden Sie bei allen Wartungs und Reparaturarbeiten ausschließlich Originaler satzteile Die Firma haftet nicht für die Sicherheit und den ordnungsgemäßen Betrieb der Automatik falls Komponenten von anderen Herstellern verwendet werden Nehmen Sie keine Änderungen an den Komponenten der Automatik vor die von der Firma nicht ausdrücklich genehmigt werden Unterweisen Sie die B...

Страница 18: ...von 3 x 1 5 mm vomTyp der von den geltenden Bestimmungen vorgeschrieben wird Verwenden Sie für den Anschluss der Motoren Kabel mit einem Mindestquerschnitt von 1 5 mm vomTyp dervondengeltendenBestimmungenvorgeschriebenwird Wenn das Kabel zum Beispiel im Außenbereich im Freien verlegt wird muss es zumindest H07RN F entsprechen während es im Innenbereich in einem Kabelkanal zumindest H05 VV F entspr...

Страница 19: ... Endschalter Schließung des Motors 2 ist frei Aus Aktivierung Eingang Endschalter Schließung des Motors 2 SWO2 An Der Endschalter Öffnung des Motors 2 ist frei Aus Aktivierung Eingang Endschalter Öffnung des Motors 2 ERR Aus kein Fehler AN siehe Tabelle Fehlerdiagnose RADIO GRÜN Aus Funkprogrammierung deaktiviert Nur LED Radio blinkend Funkprogrammierung aktiv warten versteckte Taste Synchron mit ...

Страница 20: ...urierter Eingang Fig H Pos 5 Eingang für Widerstandskante 8K2 Der Befehl kehrt die Bewegung für zwei Sekunden um OFF Als Bar konfigurierter Eingang Tastleiste Fig H Pos 3 4 Der Befehl kehrt die Bewegung für zwei Sekunden um 3 Überprüfung Eingang Fotozelle OFF ON Befähigt die Überprüfung der Sicherheitsvorrichtung am Eingang PHOT OFF Überprüfung der Sicherheitsvorrichtungen am Eingang PHOT nicht be...

Страница 21: ...as operaciones de mantenimiento y reparación La Empresa no se responsabiliza de la seguridad y el buen funcionamiento de la automatización en caso que se utilicen componentes de otros fabricantes No realizar ninguna modificación a los componentes de la automatización si no se cuenta con autorización expresa por parte de la Empresa Instruir al usuario de la instalación sobre los eventuales riesgos ...

Страница 22: ...r cable multipolar de sección mínima de 3x1 5 mm2 y del tipo previsto por las normas vigentes Paralaconexióndelosmotores utilizarcabledesecciónmínimade1 5mm2 y del tipo previsto por las normas vigentes A modo de ejemplo si el cable estáafuera descubierto debeseralmenosequivalenteaH07RN F mientras que si está cubierto en canal debe ser al menos equivalente a H05 VV F Borne Definición Descripción Al...

Страница 23: ...motor 1 es libre Apagado Activación entrada final de carrera cierre del motor 2 SWO2 Encendido el final de carrera de abertura del motor 1 es libre Apagado Activación entrada final de carrera apertura del motor 2 ERR Apagado ningún error ENCENDIDO véase tabla diagnóstico errores RADIO VERDE Apagado programación radio desactivada Parpadeante sólo LED Radio Programación radio activada espera tecla o...

Страница 24: ...ensible Fig H ref 3 4 El mando invierte el movimiento durante 2 seg 3 Control entrada fotocélula OFF ON Habilita el control de los dispositivos de seguridad en la entrada PHOT OFF Comprueba los dispositivos de seguridad en la entrada PHOT no habilitada 4 Control entrada canto OFF ON Habilita el control de los dispositivos de seguridad en la entrada BAR OFF Comprueba los dispositivos de seguridad e...

Страница 25: ...uitend originele reserveonderdelen gebruiken voor alle onderhouds of repara tiewerkzaamheden Het Bedrijf wijst iedere willekeurige verantwoordelijkheid af uit veiligheidsredenen en vanwege de goede werking van het automatiseringssysteem als er onderdelen van andere fabrikanten gebruikt worden Geen enkele wijziging uitvoeren aan de componenten van het automatiseringssys teem indien niet uitdrukkeli...

Страница 26: ...n met een doorsnede van min 1 5 mm2 en van het type voorzien door de geldende normen Als het bijvoorbeeld gaat om een externe kabel buiten moetdezetenminstegelijkzijnaanH07RN Fterwijldekabelintern in een kanaal tenminste gelijk moet zijn aan H05 VV F 5 PLAATSELIJKE COMMANDO S Fig C Het drukken op de knop ST AS bestuurt een START Het nogmaals drukken op de knop terwijl het automatiseringssysteem in...

Страница 27: ...n de eindaanslag opening motor 2 is vrij Uit Activering ingang openingsaanslag van motor 2 ERR Uit geen fout AAN zie tabel foutendiagnose RADIO GROEN Uit programmering radio gedeactiveerd Alleen led radio knippert Programmering radio actief wachten op verborgen toets Knippert synchroon met Set led Bezig met annuleren afstandsbedieningen Aan programmering radio actief wachten op gewenste toets 1 s ...

Страница 28: ...klonen 2 BAR 8K2 OFF ON Ingang geconfigureerd als Bar 8k2 Fig H ref 5 Ingang voor resistieve rand 8K2 Het commando draait de beweging 2 sec om OFF Ingang geconfigureerd als Bar gevoelige rand Fig D ref 3 4 Het commando draait de beweging 2 sec om 3 Controle ingang fotocel OFF ON Activeert de controle van de beveiligingen op de ingang PHOT OFF Controle van de beveiligingen op de ingang PHOT niet ge...

Страница 29: ...onècompletamentechiusa Porrecuraquandosi azionalosbloccosepresente poichéunatapparella aperta potrebbe cadere rapidamente in presenza di usura o rotture Larotturaol usuradiorganimeccanicidellaporta parte guidata quali ad esempio cavi molle sup porti cardini guide potrebbegenerarepericoli Far controllareperiodicamentel impiantodapersonale qualificato ed esperto installatore professionale secondo qu...

Страница 30: ...tructionsissuedbytheinstaller or manufacturer of the door When cleaning the outside always cut off mains power Keep the photocells optics and illuminating in dicator devices clean Check that no branches or shrubs interfere with the safety devices Do not use the automated system if it is in need ofrepair Intheeventtheautomatedsystembreaks down or malfunctions cut off mains power to the system do no...

Страница 31: ...ignalisation Veiller à ce que les dispositifs de sécurité ne soient pas gênés par des branches ou des arbustes Ne pas utiliser l automatisation si elle a besoin d être réparée En cas de panne ou de mauvais fonctionnement de l automatisation mettre l automatisationhorstension évitertoutetentative deréparationoud interventiondirecteets adresser uniquementàdupersonnelqualifiéetexpérimenté monteur pro...

Страница 32: ...r des Herstellers der Tür überprüfen Unterbrechen Sie vor allen externen Reinigungs arbeiten die Stromversorgung Halten Sie die Linsen der Fotozellen und die An zeigevorrichtungen sauber Stellen Sie sicher dass die Sicherheitsvorrichtungen nicht durch Zweige oder Sträucher beeinträchtigt werden Benutzen Sie die Automatisierung nicht falls sie Reparatureingriffe erforderlich macht Unterbre chenSieb...

Страница 33: ...ed Mantener limpias las ópticas de las fotocélulas y losdispositivosdeseñalizaciónluminosa Controlar que ramas y arbustos no obstaculicen los disposi tivos de seguridad No utilizar la automatización si necesita interven cionesdereparación Encasodeaveríaodedefecto defuncionamientodelaautomatización interrum pir la alimentación de red en la automatización abstenerse de cualquier intento de reparació...

Страница 34: ...deel zoals bij voorbeeldkabels veren steunen klepscharnieren geleiders kan gevaren veroorzaken De installatie periodiek laten controleren door gekwalificeerd en ervaren personeel professionele installateur volgens hetgeen aangegeven door de installateur of de deurenfabrikant Voor alle externe schoonmaakwerkzaamheden het voedingsnet loskoppelen De optieken van de fotocellen en de signalering sinric...

Страница 35: ......

Страница 36: ......

Отзывы: