PERSEO CBD 230.P SD -
19
D811944_04
INSTALLATION MANUAL
Parameter
Definition
Default
Cross Out
Setting Used
Optional Extras
Description
Sr
Request for
maintenance
00
00
disabled
the request for maintenance is not active.
01
active on the configured outputs
at the end of the countdown, by means of counters nt
and nL, one of the programmed outputs is activated
(see parameter
Av
)
02
active on the configured outputs and the bollard lights flash
twice
at the end of the countdown, by means of counters nt
and nL, one of the programmed outputs is activated
(see parameter
Av
) and the bollard lights flash twice.
Nt
Programming
maintenance
cycles in
thousands
00
00-99
Thanks to the combination of the two parameters
the countdown can be set after which a request for
maintenance is signalled.
Thousands can be set with the nt parameter, millions
with the nL parameter. Example: to set 275,000 main-
tenance manoeuvres set
nL
on 0.2 and
nt
on 75. The
value displayed in the parameters updates along with
the manoeuvres.
NL
Programming
maintenance
cycles in
millions
0.0
0.0-9.9
AV
AUX
00
00
scheduled maintenance required
If the maintenance request is enabled (
Sr
parameter),
the AUX output is activated once the value set for
parameter
nt
and
nl
is reached.
01
photocell triggering
The AUX output is activated if the photocell input is
open, photocell triggered.
02
$ non disponibile
03
PDM contact actuated
The AUX output is activated if the PDM input is closed.
04
bollard closed
The AUX output is activated when the bollard is closed.
05
bollard open
The AUX output is activated when the bollard is open.
06
stop contact actuated
The AUX output is activated if the Stop input is open.
07
warning flash
The AUX output is activated as described in the
Pf
pre-flashing parameter.
08
start contact
The AUX output is activated if the Start input is closed.
09
open contact
The AUX output is activated if the Open input is closed.
10
blackout
The AUX output is activated when the device is
switched on
11
assistance required
If configured, the contact indicates that the electronic
control unit has detected an error in the automated de-
vice and, more specifically, has detected that the limit
switches are broken. Whatever the case, the lights on
the top cap triple flash to report the error.
Te
TERMON
00
00-30
Sets the temperature difference between the bollard’s
motor and the ambient temperature in centigrade
degrees.
If the parameter is not zero, the control unit will heat
the motor in order to obtain the set temperature
difference.
Example:
TE
=15. The control unit will ensure that the
motor maintains a temperature that is 15° above the
ambient temperature.
By setting the parameter
FP
=3, it is possible to enable
or disable the Termon system, operating directly on the
PDM input.
Cr
Slow-down
speed
20
10-45
Sets the deceleration speed at the end of the closing
manoeuvre.
The value of the deceleration speed at the end of
opening is preset by the company.
TABLE “B” - LEVEL 2° PROGRAMMING