 LEO MV D - Ver. 03

D811512_03

INSTALLATION MANUAL

5) PROGRAMMING
The control panel provided with a microprocessor is supplied with function 
parameters preset by the manufacturer, suitable for standard installations. 
The predefined parameters can be altered by means of either the incorporated 
display programmer or universal palmtop programmer.
In the case where programming is carried out by means of universal palmtop 
programmer,  carefully  read  the  instructions  relating  to  universal  palmtop 
programmer, and proceed in the following way.
Connect the universal palmtop programmer to the control unit through the 
UNIFLAT accessory (See fig. 4). Enter the “CONTROL UNITS” menu, and the 
“PARAMETERS” submenu, then scroll the display screenfuls using the up/down 
arrows, and set the numerical values of the parameters listed below.
For the function logics, refer to the “LOGIC” submenu.
In the case where programming is carried out by means of the incorporated 
programmer, refer to Fig. A and B and to the “configuration” paragraph.

 

6) CONFIGURATION
The  display  programmer  is  used  to  set  all  the  LEO  MV  D  control  panel 
functions.
The programmer is provided with three pushbuttons for menu scrolling and 
function parameter configurations:  
+    

menu scrolling/value increment key 

-   

menu scrolling/value reduction key

OK 

Enter (confirm) key

The simultaneous pressure of the + and – keys is used to exit the active 
menu and move to the preceding menu.  
If the + and – keys are pressed simultaneously at the main menu level (pa-
rameters, logics, radio, language, autosetting), programming is exited and 
the display is switched off (the OK message is displayed).
The modifications made are only set if the OK key is subsequently pres-
sed.
When the OK key is pressed for the first time, the programming mode is 
entered.     
The following pieces of information appear on the display at first:
-  Control unit Software version
-  Number  of  total  manoeuvres  carried  out  (the  value  is  expressed  in 

thousands, therefore the display constantly shows 0000 during the first 
thousand manoeuvres)

-  Number of manoeuvres carried out since the latest maintenance operation 

(the value is expressed in thousands, therefore the display constantly 
shows 0000 during the first thousand manoeuvres)

-  Number of memorised radio control devices.
When the OK key is pressed during the initial presentation phase, the first 
menu (parameters) can be accessed directly.
Here follows a list of the main menus and the respective submenus avai-
lable.
The predefined parameter is shown between square brackets [ 0 ].
The writing appearing on the display is indicated between round brackets.
Refer to Figures A and B for the control unit configuration procedure.

6.1) Parameter Menu (

PARAM

1 - Automatic Closing Time (

TCA

)  [ 10s ]

 

Set  the  numerical  value  of  the  automatic  closing  time  from  1  to  180 
seconds.

2 - Slow-down Distance  (

Cm. rall

) [ 

5

 ]

 

Set the required slow-down distance for opening and closing between 

1

 and 

90

NOTE: power failure, reset, or manual gate release, the control panel 
carries out a complete manoeuvre at reduced speed, in order to learn 
the length of stroke.

3-  Alarm time (

alarm. time

)  [ 30s ]

 

In the case of obstacle detection or photocell engagement, at the end of 
the time set (ranging from 10s to 240s)  the SCA contact is closed. The 
contact is subsequently opened by the STOP command or by triggering 
of the closing limit switch. Only active when the SCA  Alarm logic is set 
to OFF.

4-  Zone (

zone

) [ 0 ]

 

Set the zone number between a minimum value of 0 and a maximum 
value of 

128

. See paragraph 

8

 on “Serial connection”.

5-  Slow-down torque  (

slud torque

 ) [ 99% ]

 

Set the motor torque value during the slow-down phase between 0% and 
99%.

6-  Opening torque (

open torque

) [ 70% ] 

 

Set the motor opening torque value between 1% and 99%. 

7-  Closing torque (

cls. torque

) [ 70% ] 

 

Set the motor closing torque value between 1% and 99%.

8 - Brake (

Brake

) [ 52% ]    

 

Set the required brake value between 0 and 99%, compatibly with the 
weight of the rod and the existing stresses.

9 - Encoder  (

Encoder

) [ 1 ] 

 

0: encoder disabled: timed slow-down, obstacle detection function not 

active. (The encoder can be disconnected).

 

1: encoder  enabled:  slow-down  and  obstacle  detection  by  means  of 

encoder (default).

WARNING:  Check  that  the  impact  force  value  measured  at  
the points established by the EN 12445 standard is lower than that 

specified in the EN 12453 standard.

Incorrect  sensitivity  setting  can  cause  injuries  to  persons  or  
animals, or damage to things.

10- Type of barrier (

barrier

) [1]

 

0:  MOOVI 30RMM/50RMM mod. barrier

 

1:  MOOVI 30S mod. barrier

 

2:  BGV mod. barrier

 

Factory-preset value, in case of maintenance or malfunctions, check the 
correspondence between the setting and the barrier model.

 

With the MOOVI 30RMM/50RMM barrier (0) , the following functions 
are not active:

  -  slow down
  -  torque setting (the barrier always works at maximum torque).

 

With the BGV barrier (2) , the following functions are not active:

  -  slow down
  -  torque  setting  (the  barrier  always  works  at  maximum  torque). 

obstacle detection.

6.2) Logic Menu (

logic.

- TCA  ( 

tca

 ) [ ON ]

ON:  Activates automatic closing
OFF:  Excludes automatic closing
- 3 Steps (

3 step

)  [ ON ] 

ON:  Enables 3-step logic. A start impulse has the following effects:
 

barrier closed:

 closed: ...........................................................................opens

 

on opening:   .............................stops and enters TCA (if configured)

 

barrier open:

 open: ............................................................................ closes

 

on closing: ......................................... stops and reverses movement

 

after stopping: ...........................................................................opens

OFF:  Disables 3-step logic
- Opening Impulse lock (

Ibl open

) [ ON ] 

ON:  The Start impulse has no effect during the opening phase.
OFF:  The Start impulse becomes effective during the opening   phase.
- Impulse lock TCA (

ibl TCA

 ) [ OFF ] 

ON:  The Start impulse has no effect during the TCA dwell period.
OFF:  The Start impulse becomes effective during the TCA dwell period.
- Pre alarm (

pre-alarM

) [ OFF ] 

ON:  The blinker comes on about 3 seconds before the motor starts.
OFF   The blinker comes on at the same time as the motor starts.  
- Photocells on opening (

photc. open

) [ ON ] 

ON:   In case of obscuring, this excludes photocell operation on opening.  

During the closing phase, it immediately reverses the motion.

OFF:  In case of obscuring, the photocells are active both on opening and 

on closing. When a photocell is obscured on closing, it reverses the 
motion only after the photocell is disengaged.

- Rapid closing (

fast cls

 ) [ OFF ]   

ON:  Closes barrier after photocell disengagement, before waiting for the

barrier after photocell disengagement, before waiting for the

 after photocell disengagement, before waiting for  the 

end of the TCA (automatic closing time) set.

OFF:  Command not entered.
- SCA Alarm (

SCA alarm

) [ ON ]

ON:   The SCA contact (terminals 12-13) behaves as follows:
 

 with barrier open and on opening:..contact closed (warning light on)

 

with barrier closed:contact open.............................(warning light off)

 

on closing: ........................................... intermittent contact (blinking) 

OFF:  The  SCA  contact  closes  according  to  the  modes  set  by  the  Alarm 

Time parameter. 

-   Master/Slave  (

Master

) [ OFF ]

ON:  The control panel is set as Master in a centralised connection (see 

Paragraph 7). 

OFF:  The  control  panel  is  set  as  Slave  in  a  centralised  connection  (see 

Paragraph 7).

-   Photocell test (

test phot

) [ OFF ] 

ON:  Activates photocell check (see Fig. 3)
OFF:  Deactivates photocell check
-   Electric edge test (

test bar

) [ OFF ]

ON:  Activates electric edge check (see Fig. 3)
OFF:  Deactivates electric edge check
-    Fixed code (

fixed code

) [ OFF ]

ON:  The  receiver  is  configured  for  operation  in  fixed-code  mode,  see 

paragraph on “Radio Transmitter Cloning”.

OFF:  The  receiver  is  configured  for  operation  in  rolling-code  mode,  see 

paragraph on “Radio Transmitter Cloning”.

ENGLISH

Содержание LEO MV D

Страница 1: ...CCIONES DE USO Y DE INSTALACION INSTRUÇÕES DE USO E DE INSTALAÇÃO I GB F D E P QUADRO COMANDO CONTROL PANEL CENTRALE DE COMMANDE STEUERUNG CUADRO DE MANDOS QUADRO DE COMANDO Via Lago di Vico 44 36015 Schio VI Tel naz 0445 696511 Tel int 39 0445 696533 Fax 0445 696522 Internet www bft it E mail sales bft it LEO MV D D811512 ver 03 21 05 07 8 027908 297235 ...

Страница 2: ... LEO MV D Ver 03 D811512_03 ...

Страница 3: ...e momento le modifiche che essa ritiene convenienti per migliorare tecnicamente costruttivamente e commercialmente il prodotto senza impegnarsi ad aggiornare la presente pubblicazione Thank you for buying this product our company is sure that you will be more than satisfied with the product s performance The product is supplied with a Warnings leaflet and an Instruction booklet These should both b...

Страница 4: ...ns or children to remain in the automation operation area Keep radio control or other control devices out of children s reach in order to avoid unintentional automation activation Theusermustavoidanyattempttocarryoutworkorrepairontheautoma tion system and always request the assistance of qualified personnel Anything which is not expressly provided for in the present instructions is not allowed Ins...

Страница 5: ...rque slud torque 99 Set the motor torque value during the slow down phase between 0 and 99 6 Opening torque open torque 70 Set the motor opening torque value between 1 and 99 7 Closing torque cls torque 70 Set the motor closing torque value between 1 and 99 8 Brake Brake 52 Set the required brake value between 0 and 99 compatibly with the weight of the rod and the existing stresses 9 Encoder Encod...

Страница 6: ...1 BOARD Fig 5 The LEO MV D control panel allows several automation units SCS1 to be connected in a centralised way by means of appropriate serial inputs and outputs This makes it possible to use one single command to open and close all the automation units connected Following the diagram in Fig 5 proceed to connecting all the LEO MV D control panels exclusively using a telephone type line Should a...

Страница 7: ...14 LEO MV D Ver 03 D811512_03 ...

Страница 8: ...LEO MV D Ver 03 15 D811512_03 ...

Страница 9: ...36 LEO MV D Ver 03 D811512_03 Fig 1 Fig 2 Fig 3 236 194 100 MOOVI BGV ...

Страница 10: ...s Contacts Kontakte Contactos Contatos 1 3 4 2 1 3 4 2 1 2 3 4 1 2 3 4 UNIPOWER UNIFLAT UNIFLAT UNIMITTO UNITRC UNIMITTO UNITRC P1 T1 Led T2 TRC 1 2 P1 P1 T1 T2 T3 T4 P1 P1 T1 Led T2 P1 P1 T1 T2 T3 T4 P1 P1 P1 Contatti Contacts Contacts Kontakte Contactos Contatos Programmatore palmare universale Universal palmtop programmer Programmateur de poche universel Universellen Palmtop Programmierer Progr...

Страница 11: ...38 LEO MV D Ver 03 D811512_03 Fig 6 Fig 5 SCS1 SCS1 SCS1 Max 250m TX1 TX2 RX1 RX2 TX1 TX2 RX1 RX2 TX1 TX2 RX1 RX2 SCS1 ...

Страница 12: ...LEO MV D Ver 03 39 D811512_03 Fig 7 JP4 18 19 20 NO NC COM JP4 18 19 20 NO NC COM ...

Страница 13: ......

Отзывы: