background image

INSTALLATION MANUAL

-   Closing torque (

Cls.Torque

) [ 50% ]  

  Set the numerical value of the motor’s closing torque in the range 1% to 99%.

NOTE: In case of obstacle detection, the Ampere-stop function halts the 

leaf movement, reverses the motion for 1 sec. and stays in the STOP state.

WARNING: Check that the force of impact measured at the points 

provided for by standard EN 12445 is lower than the value laid down 

by standard EN 12453.
Setting sensitivity incorrectly can result in damage to property and injury 

to people and animals.

-  Partial opening (

part.open

) [ 1.0 m ] 

 

  Set the numerical value of partial opening in the range 10 cm (0.001) to 6 m 

(006.0)

-  Zone (

Zone

) [ 0 ]

 

  Set the zone number between a minimum value of 0 and a maximum value 

of 127. See section 11 entitled “Serial connection”.

-  Running speed during opening (

op speed

) [99%] 

  Sets the maximum opening speed reached by the actuator at running speed. 

  The value is given as a percentage of the maximum speed the actuator can 

reach.

- Running speed during closing (

cl speed

) [99%]

 

  Sets the maximum closing speed reached by the actuator at running speed. 

  The value is given as a percentage of the maximum speed the actuator can 

reach.

-  Slow-down distance (

dist.sloud

) [007] 

  Sets the slow-down distance travelled by the actuator during opening and closing. 

   The value is given in centimetres.

Editing one of the following parameters:

-  Running speed during opening

-  Running speed during closing

-  Slow-down distance

results in the actuator performing a complete opening/closing cycle with the 

anti-crush  feature  switched  of.  The “SET”  message  lashes  on  the  display  to 

warn that this cycle is in progress.

8.3) LOGIC MENU (

LOGIC

)

- Automatic Closing Time (

TCA

) [ OFF ]

ON: 

Switches automatic closing on

OFF:  Switches automatic closing of

- 3 Step (3 Step) [OFF]

ON: 

 Switches to 3-step logic.    

 

 

 A start pulse has the following efects:

 

 

door closed:............................................................................................................opens

 

 

during opening:..............................stops and switches on TCA (if conigured)

 

 

door open:..............................................................................................................closes

 

 

during closing:.......................................................stops and movement is reversed

 

 

after  stop: ..................................................................................................................opens

OFF:  Switches of 3-step logic.

-  

Block opening pulses

 (

ibl open

)

 [ OFF ]

ON:   The start pulse has no efect during opening.

OFF:  The start pulse has efect during opening. 

 Pre-alarm (

pre-alarm

) [ OFF ]

ON: 

The lashing light comes on approx. 3 seconds before the motor starts.

OFF:  The lashing light comes on at the same time as the motors start.

-  Photocells during opening (

Photoc.open

) [ OFF ]

ON:  when beam is broken, operation of the photocell is switched of during 

opening. During closing, movement is reversed immediately.

OFF:  when beam is broken, photocells are active during both opening and 

closing. When beam is broken during closing, movement is reversed only 

once the photocell is cleared.

-  Photocell test (

test phot

) [ OFF ]

ON: 

Switches photocell testing on (see ig. 17A)

OFF:  Switches photocell testing of

-  Gate open light or 2nd radio channel (

SCA 2Ch

) [ ON ]

ON: 

The output between terminals 14-15 is set as Gate open light: in this case, 

the 2nd radio channel controls partial opening.

OFF:  The output between terminals 14-15 is set as 2nd radio channel.

-  Fixed Code (

fixed code

) [ OFF ]

ON:  Receiver is conigured for operation in ixed-code mode, see “Radio 

transmitter cloning” section.

OFF:  Receiver is conigured for operation in rolling-code mode, see “Radio 

transmitter cloning” section.

-  Remote control programming  (

radio prog

) [ ON ]

ON: 

Enables wireless memorizing of transmitters (Fig.20):

 

1- Press in sequence the hidden key (P1) and normal key (T1-T2-T3-T4) of 

a transmitter that has already been memorized in standard mode via the 

radio menu. 

 

2- Press within 10 sec. the hidden key (P1) and normal key (T1-T2-T3-T4) 

of a transmitter to be memorized. 

 

The receiver exits programming mode after 10 sec.: you can use this time 

to enter other new transmitters. 

 

This mode does not require access to the control panel.

OFF:  Disables wireless memorizing of transmitters.   Transmitters  are  memo-

rized only using the relevant Radio menu.

- START - OPEN setting  (

start-open

) [ OFF ]

ON: 

Input between terminals 3-4 works as OPEN.

OFF:  Input between terminals 3-4 works as START.

- PED-CLOSE setting  (

ped-close

) [ OFF ]

ON: 

Input between terminals 16-17 works as CLOSE.

OFF:  Input between terminals 16-17 works as PARTIAL OPENING.

- Master/Slave (

master

) [ OFF ]

ON: 

Control panel is set up as the Master unit in a centralized connection sys-

tem. 

OFF:  Control panel is set up as a Slave unit in a centralized connection system.

8.4) RADIO MENU (

RADIO

)

-  Add

 

Used to add a key on a remote control to the receiver’s memory.  

 

Once memorized, it returns the number of the receiver in the memory loca-

tion (from 01 to 64).

- Add Start Key (

Add start

)

 

associates the desired key with the Start command 

- Add 2ch Key (

Add 2ch

)

 

associates the desired key with the 2nd radio channel command

- Read (

Read

 

Checks a key of a receiver and, if memorized, returns the number of the re-

ceiver in the memory location (from 01 to 64) and number of the key (T1-T2-

T3 or T4).

- Erase List  (

erase 64

)

WARNING! Erases all memorized remote controls from the receiver’s 

memory.

- Read receiver code (

cod RX

)

 

 

Displays the code entered in the receiver.

- W LINK (

uk

)

 

ON = 

 

Enables remote programming of cards via a previously memorized W LINK 

remote control. It remains enabled for 3 minutes from the time the W LINK 

remote control is last pressed.

 

Refer to the W LINK remote control’s manual for the mapping of the relevant 

keys.

 

OFF = 

 

W LINK programming disabled.

Consult sections 8/9/10/11 for further information on the built-in Clonix 

receiver’s advanced features.

8.5) LANGUAGE MENU (

LANGUAGE

)

Used to set the programmer’s language on the display.

There are 5 language options:

-   ITALIAN (

ITA

)

-   FRENCH (

FRA

)

-   GERMAN (

DEU

)

-   ENGLISH (

ENG

)

-   SPANISH (

ESP

)

8.6) DEFAULT MENU (

DEFAULT

)

Restores the controller’s default factory settings. Following this reset, you will 

need to run the autoset function again.

8.7) DIAGNOSTICS AND MONITORING

The display on the

 VENERE D

 panel gives a certain amount of useful information 

both during normal operation and when faults are detected.

Diagnostics:

In the event of malfunctions, the display gives a message showing which device 

needs checking:

STRT 

= START input activated

STOP 

= STOP input activated

PHOT 

= PHOT input activated

SWO 

= OPENING LIMIT SWITCH input activated

SWC 

= CLOSING LIMIT SWITCH input activated

PED 

= PEDESTRIAN input activated

OPEN 

= OPEN input activated

CLS 

= CLOSE input activated

In the event the door encounters an obstacle, the 

VENERE D

 panel stops the door 

and commands it to reverse, while on the display the “AMP” message appears

Monitoring:

During opening and closing, the display shows four numbers separated by a 

decimal point, e.g. 

35.40

. The numbers are updated constantly during the door’s 

operation and stand for the instantaneous torque reached by motor 1 (

35

) and 

torque threshold (opening, closing, slow-down) set in the parameters menu (

40

). 

Via these values, we can correct the torque setting.  

If the value of the instantaneous torque reached during the door’s operation gets 

rather close to the threshold value set in the parameters menu, malfunctioning 

may occur in the future due to wear or the door becoming slightly misshapen. 

Consequently, it is advisable to check the maximum torque reached during a 

number of cycles at the installation stage and, where necessary, set a value ap-

prox. 5/10 percentage points higher in the parameters menu.

8.8) ERROR DIAGNOSTICS:
ER01 

Error in safety device (photocell) test

ER10 

Problems detected in motor’s control circuit

ER11 

Problems detected in motor’s current reading circuit

8.9) AUTOSET MENU

 

Move the door to the closed position

•  Launch an autoset operation by going to the relevant menu on the VENERE 

D panel (Fig.B).

•  As soon as you press the OK button, the “........ ....” message is displayed and the 

control unit commands the door to perform a full cycle (opening followed 

by closing), during which the minimum torque value required for the door 

to move is set automatically. 

 

During this stage, it is important to avoid breaking the photocells’ beams and 

not to use the START and STOP commands or the display. 

 

Once this operation is complete, the control unit will have automatically set 

the optimum torque values. Check them and, where necessary, edit them as 

described in the programming section.

WARNING: Check that the force of impact measured at the points  

provided for by standard EN 12445 is lower than the value laid down 

by standard EN 12453.

Warning!! While the autoset function is running, the obstacle detection 

function is not active. Consequently, the installer must

8.10) LIMIT SWITCH ADJUSTMENT MENU

The VENERE D control panel has an opening and closing limit switch adjustment 

menu, which simpliies the installation procedure.

Refer to Figures 18/19 and Fig.B illustrating the control panel’s programming 

and proceed as follows:  

16 -

 EOS 120 VENERE D

D811526 00100_02

Содержание EOS 120 VENERED

Страница 1: ...ASCULANTES ET SECTIONALES GARAGENTORANTRIEB F R SCHWING UND SEKTIONALTORE AUTOMATIZACIONES PARA PUERTAS BASCULANTE Y SECCIONALES AUTOMATISERINGEN VOOR KANTEL EN SECTIEDEUREN Attenzione Leggere attenta...

Страница 2: ...of children s reach in order to avoid any unintentional automation activation Do not intentionally oppose the leaf movement Do not attempt to open the door manually if the internal locking system has...

Страница 3: ...ere they will not cause a hazard away from moving parts More speciically hold to run controls must be positioned withindirectsightofthepartbeingcontrolledand unlesstheyarekeyoperated must be installed...

Страница 4: ...safety and control devices to reach the motor unit keeping the mains voltage connections clearly separate from the extra low safety voltage connections 24V by means of the appropriate cable holder ig...

Страница 5: ...ion sys tem OFF Control panel is set up as a Slave unit in a centralized connection system 8 4 RADIO MENU RADIO Add Used to add a key on a remote control to the receiver s memory Once memorized it ret...

Страница 6: ...CEIVER COMMUNITY Refer to the UNIRADIO instructions and CLONIX programming guide 9 6 REMOTE TRANSMITTER PROGRAMMING Fig 20 1 Press the hidden key P1 of a transmitter that has already been memorized in...

Страница 7: ...G Wait message enter value or function Simultaneously press the and keys Simultaneous pressure of the and keys allows you to exit the active menu and return to the preceding menu if this takes place a...

Страница 8: ...B2 Release P1 on radio control device ADD start hidden button release desired button 01 PRG READ OK OK OK ERASE 64 Press P1 pushbutton on radio control device Press the required T key on radio control...

Страница 9: ...146 253 16 65 378 35 3380 2780 3760 3160 1 2 250 E14 24V 25W max 44 EOS 120 VENERE D D811526 00100_02...

Страница 10: ...C C D D B A D Tassello Plug Cheville D bel Taco Plug EOS 120 VENERE D 45 D811526 00100_02...

Страница 11: ...300 mm E C B Tassello Plug Cheville D bel Taco Plug D A C D D A 46 EOS 120 VENERE D D811526 00100_02...

Страница 12: ...EOS 120 VENERE D 47 D811526 00100_02...

Страница 13: ...48 EOS 120 VENERE D D811526 00100_02...

Страница 14: ...EOS 120 VENERE D 49 D811526 00100_02...

Страница 15: ...GESLOTEN DEUR Fig 26 Montage doppen voor aandrijving EOS 120 VENERE D 50 EOS 120 VENERE D D811526 00100_02...

Отзывы: