BFT ALTAIR Скачать руководство пользователя страница 2

355

ALTAIR 

ALTAIR 

Thank you for buying this product, our company is sure that you will be more
than satisfied with its performance.
This product is supplied with an 

Instruction Manual

 which should be read

carefully  as  it  provides  important  information  about  safety,  installation,
operation and maintenance.
This  product  complies  with  recognised  technical  standards  and  safety
regulations. We declare that it is in conformity with the following European
Directives: 89/336/EEC, 73/23/EEC and subsequent amendments.

1) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.

The

Warnings

  leaflet  and 

Instruction  booklet

  supplied  with  this

product should be read carefully as they provide important information
about safety, installation, use and maintenance.

Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children

s reach.

Keep  the  instructions  together  with  the  technical  brochure  for  future
reference.

This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.

The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.

Do not install the product in explosive atmosphere.

The  construction  components  of  this  product  must  comply  with  the
following  European  Directives:  89/336/CEE,  73/23/EEC,  98/37/EEC
and subsequent amendments. As for all non-EEC countries, the above-
mentioned standards as well as the current national standards should
be respected in order to achieve a good safety level.

The Company declines all responsibility for any consequences resulting
from  failure  to  observe  Good  Technical  Practice  when  constructing
closing structures (door, gates etc.), as well as from any deformation
which might occur during use.

The installation must comply with the provisions set out by the following
European  Directives:  89/336/CEE,  73/23/EEC,  98/37/EEC  and
subsequent amendments.

Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.

Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.

Check that a differential switch with a 0.03A threshold is fitted just before
the power supply mains.

Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.

Fit  all  the  safety  devices  (photocells,  electric  edges  etc.)  which  are
needed  to  protect  the  area  from  any  danger  caused  by  squashing,
conveying and shearing.

Position at least one luminous signal indication device (blinker) where
it can be easily seen, and fix a Warning sign to the structure.

The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers

 components

are used.

Only use original parts for any maintenance or repair operation.

Do not modify the automation components, unless explicitly authorised
by the company.

Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.

Do  not  allow  persons  or  children  to  remain  in  the  automation
operation area.

Keep radio control or other control devices out of children

s reach, in

order to avoid unintentional automation activation.

The  user  must  avoid  any  attempt  to  carry  out  work  or  repair  on  the
automation  system,  and  always  request  the  assistance  of  qualified
personnel.

Anything which is not expressly provided for in the present instructions,
is not allowed.

1) GENERAL OUTLINE

The

ALTAIR

 control panel is suitable for swing gates. It is supplied by the

manufacturer with standard functional settings. Any alteration must be set
by means of the incorporated display programmer or by means of 

UNIPRO

and

UNIRADIO

. The Control unit completely supports the 

EELINK

 protocol.

The most significant innovative characteristics of the Altair control panel are:
-

management of two motors with electronic torque setting, see paragraph3

-

management of on-board receiver, according to the new type of radio-
control cloning, see paragraph 8

-

presetting for operation with local or centralised controls via wire, see
paragraph 11.

Its main characteristics are:
-

Power supply: 230V

±

10% 50Hz (other voltages on request)

-

No-load absorption from the mains: 0.2A max

-

Maximum power with 2 motors: 300W each

-

Maximum power with 1 motor: 300W

-

Motor force limitation: to be set electronically

-

Blinker output: 40W max

-

Gate-open warning light output: 24V

 3W max

-

Supply output for accessories: 24V 

 5VA max

-

Manoeuvre limit switch: with operation time limitation, operation time to
be set

-

Safety inputs: Stop, photocells

-

Control inputs: Start, pedestrian

-

Operational options: various, depending on the settings and controls
applied

-

Radio receiver: 433.92 MHz rolling-code or fixed code

-

Maximum numbers of radio control devices to be managed: 63

-

Centralised controls with other controllers: presetting for serial protocol
with an external accessory.

3) CONTROL UNIT TECHNICAL SPECIFICATIONS

Power supply: ........................................................... 230V

±

10% 50Hz*

No-load absorption from the mains: ............................................ 0.2A max
Mains/low voltage insulation: ....................................... > 2MOhm 500Vdc
Dielectric strength: ..................... mains/low voltage 3750Vac for 1 minute
Motor output current: ...................................................... 1.25A+1.25Amax
Motor relay commutation current: ........................................................ 10A
Maximum power with 2 motors: ............................................ 300W+300W
Maximum power with 1 motor: .......................................................   300W
Blinker: ........................................................................................  40W max
Gate-open warning light: ................................................... 24V

 3W max

Supply to accessories: ................................ 24V

 (0.2A max absorption)

Degree of protection for box: ............................................................ IP 55
Dimensions: ............................................................................. see figure 1
Fuses: ...................................................................................... see figure 2
(*other voltages available on request)

4) TERMINAL BOARD CONNECTIONS (Fig.3)
WARNING - 

During wiring and installation operations, refer to the current

standards and to principles of good technical practice.

Wires  powered  at  different  voltages  must  be  physically  separated,  or
suitably insulated with at least 1 mm extra insulation. The wires must be
clamped by an extra fastener near the terminals, for example by bands.

WARNING! For connection to the mains, use a multipolar cable with
a  minimum  of  3x1.5mm

2

  cross  section  and  complying  with  the

previously mentioned regulations. For example, if the cable is out side
(in the open), it has to be at least equal to H07RN-F, but if it is on the
inside (or outside  but placed in a  plastic cable cannel) it has to be or
at least egual to H05VV-F with section 3x1.5mm

2

.

JP7

1

GND terminal

2-3

Single-phase mains supply (2=L) (3=N)

JP8

4-5-6

Connection to motor 1:
4 on 1
5 common (blue)
6 on 2

7-8-9

Connection to motor 2:
7 on 1
8 common (blue)
9 on 2

10-11

230Vac output for blinker light (40W max)

JP9

13-14

24V

 200mA max output 

 supply to photocells or other devices

15-16

Output (N.O. contact (24V

/0.5A max)) for gate-open warning

light  or,  alternatively,  2nd  radio  channel  (see  paragraph  6

configuration

)

17-18

STOP  pushbutton  (N.C.)  input.  If  not  used,  leave  the  bridge
connected.

D811321_04

CONTROL UNITS

CONTROL UNITS

Содержание ALTAIR

Страница 1: ...CONTROL UNIT ALTAIR D811321 05 05 02 Vers 04 ...

Страница 2: ...n to remain in the automation operation area Keep radio control or other control devices out of children s reach in order to avoid unintentional automation activation The user must avoid any attempt to carry out work or repair on the automation system and always request the assistance of qualified personnel Anything which is not expressly provided for in the present instructions is not allowed 1 G...

Страница 3: ...ir control unit does not supply the UNIPRO programmer which therefore needs an appropriate supply unit Enter the CONTROL UNITS menu and the PARAMETERS submenu then scroll the display screenfuls using the up down arrows and set the numerical values of the parameters listed below Operation time vork t 10s Set the numerical value of the operation time from 3 to 90 seconds Automatic Closing Time TCA 1...

Страница 4: ...ase of manual programming the first transmitter assigns the key code to the receiver this code is necessary in order to carry out subsequent cloning of the radio transmitters 10 RADIO TRANSMITTER CLONING Clones can be added by means of UNIRADIO and the only limitation to this is the maximum number of transmitters the receiver can memorise Note in rolling code cloning the level of safety of the cod...

Страница 5: ...as already been assigned to a collective receiver or vice versa Example T1 output 1 Start collective receiver and T2 output 1 Start individual receiver b Transfer of programming data 6 Exit the list parameter menu by pressing ESCAPE and return to the initial menu 7 Use the arrow up and arrow down keys to select item go the menu number 8 Press enter 9 When in the subsequent menu type number 223 and...

Страница 6: ...NTROL UNITS STATISTICSmenuandscrollthescreenfuldisplayingstatisticalparameters Board microprocessor software version Number of cycles carried out If the motors are replaced take down the number of manoeuvres carried out up to that time Number of cycles carried out since the latest maintenance operation It is automatically set to zero after each self diagnosing or parameter writing operation Dateof...

Страница 7: ...pressed in tenths of a second default 10 0 10s min 3 0 3s max 60 0 60s TCA automatic closing time value expressed in seconds default 10 10s min 3 3s max 90 90s Motor torque Ð value expressed in default 50 min 1 max 99 Opening phase difference Time value expressed in tenths of a second default 1 0 1s min 1 0 1s max 5 0 5s Closing phase difference Time value expressed in tenths of a second default 1...

Страница 8: ...s a g e s h o w i n g t h e r e c e i v e r n u m b e r i n t h e memory location from 01 to 64 T1Start T2ch Ð automatically associates key T1 to Start command and key T2 to 2nd radio channel Button StartÐ associates the required key to Start command Button 2ch Ð associates the required key to 2nd radio channel READ Checks one key on a receiver if stored it displays a message showing the receiver ...

Страница 9: ...100 ALTAIR SD 13 14 15 16 17 18 19 21 21 4 5 6 7 8 9 10 11 0 1 AT 2 5 AT 1 2 3 32 31 8888 13 14 15 16 17 18 19 21 21 4 5 6 7 8 9 10 11 12 8888 JP9 JP9 13 14 15 16 17 18 19 20 21 STOP COM NC NC NO NO PHOT 24 V 24 V START PED SCA II CH R 13 14 15 SCA II CH 16 JP9 13 14 15 16 CLONIX 64 D811321_04 ALTAIR ALTAIR CONTROL UNITS CONTROL UNITS ...

Страница 10: ...s Contatos UNITRC UNIFLAT Contatti Contacts Contacts Kontakte Contactos Contatos TRC1 2 TRC4 UNIMITTO MITTO 2 4 UNIFLAT Contatti Contacts Contacts Kontakte Contactos Contatos TRC1 2 TRC4 1 3 4 1 2 2 3 4 UNIMITTO UNITRC JP3 J1 8888 UNIDA UNIFLAT ALTAIR P1 T1 Led T2 TRC 1 2 P1 P1 TRC4 T1 T2 T3 T4 P1 MITTO 2 4 D811321_04 ALTAIR ALTAIR CONTROL UNITS CONTROL UNITS ...

Страница 11: ...1A9C 22FD 00 1A9C 22FD 02 1A9C 22FD 01 UNIRADIO 1A9C 22FD 01 8888 ALTAIR JP5 ALTAIR SCS1 ALTAIR SCS2 RX1 RX2 TX1 TX2 RX1 RX2 TX1 TX2 RX1 RX2 TX1 TX2 ALTAIR SCS3 Max 250m SCS 1 2 3 4 1 2 3 4 1 2 3 4 D811321_04 ALTAIR ALTAIR CONTROL UNITS CONTROL UNITS ...

Отзывы: