SECTION 1
INFORMATION AND REQUIREMENTS
1.0
APPLIANCE INFORMATION
Main injector : (1 off)
Stereomatic Cat 82 – size 2.00 (NG)
Stereomatic Cat 82 – size 1.31 (LPG)
Pilot Type :
NG - Polidoro G27.2
LPG - Polidoro G24.1
Max. Gross Heat Input :
6.3 kW
Min. Gross Heat Input :
2.0 kW
Cold Inlet Pressure :
G20 20.0+/-1.0 mbar (8.0 +/- 0.4 in w.g.)
G31 37.0+/-1.0 mbar (14.8 +/- 0.4 in w.g.)
Ignition :
Integral to gas valve
Electrode Spark Gap :
4.0mm
Packed Weight Combustion Chamber : 76.0 kg (Pack 1 of 2)
Packed Weight Flue Terminal Pack
: 16.0 kg (Pack 2 of 2)
Supply Voltage :
230V a.c.
Supply Frequency :
50Hz
Supply Fuse :
3 Amp to BS 1362
Electrical Supply Required
230v AC, 50Hz
Fig. 1
Fig. 2
Top View of Combustion
Side View of Combustion
Chamber
Chamber
3
870mm
795mm
370 mm
540mm
595mm
370mm
175mm
111mm
125mm
25mm