2.5
INSTALLATION OF THE GAS SUPPLY (INTO STUDDED WALL OR
EXISTING CHIMNEY BREAST)
2.5.1
Before installing the combustion chamber, decide from which side or if a
rear connection to the gas supply is required. Plan the pipe run to enter
from the rear or below the firebox from the left, right or rear and connect
to the inlet elbow. See figure 10, 11 & 12 below. The gas connection is
located at the front right hand side of the fire.
Note : Before breaking
into the gas supply a gas tightness test should be carried out to
establish that the existing pipework is sound.
12
Combustion Chamber
Gas Supply entering from L/H/S
Combustion Chamber
Gas Supply entering from Rear of Combustion Chamber
Outer
Cavity Wall or
rear face of
studwork
Ensure if bringing gas
supply through side or rear
of a chimney breast that the
pipe is sleeved and sealed
with a suitable flexible, non
setting compound
Fig. 10
Fig. 11
Combustion Chamber
Fig. 12
Gas Supply entering from R/H/S