SECTION 4
MAINTENANCE
Servicing Notes
Servicing should be carried out annually by a competent person such as a
GAS SAFE registered engineer. It is a condition of BFM Europe’s lifetime
guarantee scheme that this is carried out by a competent person i.e a GAS
SAFE registered Engineer in accordance with these servicing notes, and the
pilot must also be changed as a requirement of the guarantee.
The condition of the logs should be checked and if necessary the whole set
should be replaced with a genuine replacement set.
After any servicing work a gas tightness check must always be
carried out.
During the annual service, the flue pipes should be inspected and replaced
as necessary.
4.1
Removing the burner assembly from the fire.
4.1.1
Isolate the gas supply.
4.1.2
Remove the glass panel assembly as shown in section 2.13
4.1.4
Remove the log set and loose bark chippings from the combustion
chamber base, taking care not to damage the logs. Remove the
retaining pegs from the ceramic logs.
4.1.5
Remove the fibre base panel that surrounds the burner, using a flat, thin
object such as a steel rule under the front edge to lever it upwards.
4.1.6
Remove the 6 off screws that retain the ceramic support and lift it clear.
4.1.7
Remove the 4 off burner retaining screws, and the injector / injector
supply pipe.
4.1.8
Remove the injector retaining screw from the venturi, the burner can
then be lifted clear.
4.1.9
Replace in reverse order and carry out a gas tightness test.
4.2
Removing the Injector
4.2.1
Isolate the gas supply.
40