ENGLISH
2
Connecting the BC-16 to DC-12 and DC-22 Entro Door Controllers - or the DC800 Entro Lite
Door Controller
Note!
For
Entro
: connect to the
Clock & Data
terminal block. Set the link J4 in the door controller to
+V
= Vin,
but NEVER exceed
12V as power supply
. A Higher voltage will damage the reader beyond
repair.
For
Entro Lite
set jumper J in the DC800 to
Vin
and set jumper J4 to
Clock & Data
, but NEVER
exceed 2V as power supply. A Higher voltage will damage the BC-6 beyond repair.
Power to the BC-6 will be supplied from the Door Controller.
Red
Black
Green
Blue
Yellow
Screen to Earth Node
DC-22
DC-12
DC800
(+ 12Volt)
(0 Volt)
(Green LED)
(Data)
BC-16
(Clock)
15
16
18
19
20
14
15
17
18
19
5
Connecting the BC-16 to DC-12 and DC-22 Entro Door Controllers - or the DC800 Entro Lite
Door Controller
For a two-reader operation, a Bewator Multibox, must be used.
Note!
For
Entro
: connect to the
Clock & Data
terminal block. Set the link J4 in the door controller to
+V
= Vin,
but NEVER exceed
12V as power supply
. A Higher voltage will damage the reader beyond
repair.
For
Entro Lite
set jumper J in the DC800 to
Vin
and set jumper J4 to
Clock & Data
, but NEVER
exceed 2V as power supply. A Higher voltage will damage the BC-6 beyond repair.
Power to the BC-6 will be supplied from the Door Controller.
Screen to Earth Node
Screen to Earth Node
Yellow
Black
Red
Violet
Blue
Green
Yellow
Black
Blue
Red
Violet
Green
1
2
3
4
5
6
7
8
9
10
19
15
18
16
20
Clock
+V
Green
0V
Data
10 9 8 7 6 5 4 3 2 1
1 2 3 4 5 6 7 8 9 10
6
5
4
3
2
1
PL1
PL4
PL2
PL3
BC-16
DC-22
DC-12
18
14
17
15
19
DC800
Multibox
BC-16
5
Technical specifications
Power supply:
2 Vdc.
Temperature range:
-20 to +55 °C.
Power consumption:
70 mA min, 300mA max.
Dimensions HxWxD mm: 89 x 34 x 34.
Weight (packed):
300g.