ELECTRICAL RATING
For models equipped with 120V, 60HZ, 1PH
ELECTRICAL CONNECTION:
The cabinet heating unit has a 2000-watt heating element
and requires a 20-amp circuit. If required circuit is not
available, wiring should be performed by a qualified and
certified electrician.
For models equipped with 220V, 50HZ, 1PH
ELECTRICAL CONNECTION:
Equipped with a female “IEC 60320 C20” Power inlet which
accommodates various power cord configurations for
applicable country. The cabinet heating unit has a 2000-
watt heating element and requires a 9-amp circuit.
NEMA 5-20R
20 AMP RECEPTACLE
IEC 60320 C20 POWER INLET (9 amp)
.
NOTE: Be sure unit is grounded.
Check ground connection. Do not use
if unit is not grounded
LOCATION
Your unit should be located to provide easy access, without restrictions. Factory installed door opens from
left to right. Provisions for mounting door to open from right to left are incorporated.
Electrical outlet must be less than (6) ft. from unit operating position. Avoid enclosed or confined locations,
which will restrict air circulation.
1.) Locate and remove cord holder bracket on top of heater body inside cabinet. See figure 1.
2.) Remove (2) screws from upper right rear of cabinet for later installation See figure 2.
3.) Install bracket with (2) screws and tighten. See figure 3. Completed install see figure 4.
Electrical Cord Holder Installation
Figure 1
Figure 4
Figure 3
Figure 2
OPERATING PROCEDURES
CONTROL PANEL CONFIGURATION
ELECTRICAL