background image

6-1m. Replacing the High-temperature safety thermostat.

6-1 n. Replacing the top mounted heating module seal (gasket).

**NOTE:

6.1o. Replacing the fan blower cooling fan for CA43 units.

Required: Medium (6”) flathead screwdriver, Medium (6") phillips

screwdriver, Crescent wrench

1. Remove top mounted heating module as found in section 6-1a.

2. Remove four screws that secure the air deflector housing (on your

right as you are facing the front of heating module) to the module with

a medium (6”) flathead screwdriver.

3. Gently lift the air deflector housing to access the nuts and connecting

wires to the high temperature safety thermostat. Remove those nuts

and washers to free the wires and the thermostat.

4. Attach the new high-temperature thermostat and reconnect the new

wires.

5. Reconnect air deflector housing to heating module with the four

flathead screws.

6. Replace top mounted heating module (section 6-1 a).

Required: Razor blade, General Electric 1209 caulking

1. Remove top mounted heating module as found in section 6-1a.

2. Razor blade old gasket and foam tape off of the heating module. (Fig.

53)

Remove all caulking and material carefully. A good seal

requires a clean surface.

3. Set new gasket into place using double-face foam tape (included with

new gasket) to attach new gasket to module. (Fig. 54)

4. Caulk inner and outer edges of new gasket with GE 1209 caulking.

Allow caulking to dry for at least 45 minutes. (Fig. 55)

5. Replace top mounted heating module (section 6-1a).

Required: Medium (6”) flathead screwdriver, Medium (6”) phillips

screwdriver, Wiring markers (color or number codes), Electrical tape

1. Remove the back panel of the module by removing the five flathead

screws and gently removing the back panel. Lay the panel on a clean

work surface.

2. Remove four screws inside the back panel that secure the cooling fan

to the back panel with a medium (6”) flathead screwdriver. Save

spacers for reuse. (Fig. 56)

3. Mark all the wires connected to the cooling fan with a color code or

number to make proper re-connection easy. (Fig. 57)

4. Remove wire nuts and retain wire sleeve for reuse. Discard old

cooling fan (if under warranty and requested by BEVLES, send fan

and Return MaterialAuthorization form to the factory for credit).

5. Slip reserved wire sleeve onto the wires of the new cooling fan.

6. Connect new cooling fan wires to existing wires. It is not important

which way you match the new wires.

7. Carefully insert nylon spacers between the cooling fan and back

panel. Connect new fan to the back panel with the four flathead

screws. (Fig. 56)

8. Replace back panel with the five flathead screws.

9. Replace top mounted heating module (section 6-1a).

Figure 53

Figure 54

Figure 55

Figure 56

Figure 57

18

Содержание CA43-CV13

Страница 1: ...l sales BevLes com 214 421 7366 BevLes 729 Third Avenue Dallas TX 75226 Innovative Foodservice Equipment Custom Designed for Performance Service and Value CA34 CV9 CA43 CV7 or CV13 CA70 CV16 or CV32 C...

Страница 2: ...ODULE 9 THERMOSTAT INDICATOR LAMP MODULE 10 POWER SWITCH 10 THERMOMETER 11 POWER CORD FOR CA70 11 POWER CORD FOR CA43 12 THERMOSTAT FOR CA70 13 THERMOSTAT FOR CA43 14 FAN BLOWER MOTOR ASSEMBLY 16 HEAT...

Страница 3: ...intenance of original product occurs If at any time a claim is reported to Bevles the purchaser is delinquent in payment for the product warranty will not apply 5 Buyer s Remedies If a Bevles product...

Страница 4: ...l components Dutch doors are mounted on the front with a full length door on the back for 70 inch models All doors are removable and equipped with patented positive extruded latches Standard models of...

Страница 5: ...teel wool or caustic cleaning compounds on your BEVLES holding cabinet 1 Push power switch to the OFF position 2 Unplug power cord from wall Always unplug the unit before dismantling or cleaning 3 Rem...

Страница 6: ...unit into wall Check the serial number label located on the right side of the cabinet as you are facing the front of the unit at the top to be sure that your unit is compatible with your electrical su...

Страница 7: ...120 240 18 5 9 3 CA 70 CV32 1 1 2 32 70 24 31 1500 120 240 14 3 7 2 CA 70 CV32HW 1 1 2 32 70 24 31 2000 120 240 18 5 9 3 CA70 CVMP12 4 12 24 70 29 31 2000 120 240 18 5 9 3 CA70 CVMP15 3 1 4 15 30 70 2...

Страница 8: ...ot in on position Loose or unplugged power cord Faulty heater fan blower Faulty internal wiring Too much humidity in air flow Holding temperature not high enough Holding product too long in cabinet Wa...

Страница 9: ...r Medium 6 flathead screwdriver 1 Remove all five screws from the face of the front panel at the four corners and center top 2 Gently lift off the front panel while guiding attached wires and thermome...

Страница 10: ...into place 7 Reconnect wiring with one of the two new wires going to the wire nut and the other to the back of the thermostat it doesn t matter how you match the new module wires Re tape over wire nut...

Страница 11: ...er so that the elbow connector for the power cord is up Free the green ground wire by grasping the nut with fingers or pliers under front overhang of the heating module and remove the screw from the e...

Страница 12: ...ther two power cord wires by removing the two wire nuts they are attached to 5 Remove elbow connector that secures power cord onto the back panel While grasping the nut on the inside surface of the pa...

Страница 13: ...ll the wires connected to the thermostat with a color code or number to make proper re connection easy Fig 27 3 Remove thermostat dial from front panel by rotating the dial to expose the set screw and...

Страница 14: ...5 1 Thermostat Indicator Lamp Power Switch 0 1 2 3 0 5 Thermostat Diagram 4 Power Cord Grd 2 3 4 1 Heating Element 4 5 Klixon Thermostat 0 1 Cooling Fan 6 1j Replacing the thermostat for CA43 units R...

Страница 15: ...stat unit using the thermostat wiring diagram for CA43 units Re tape over wire nuts and wires Diagram 5 12 Attach new thermostat to rear of front panel and bezel to the front of panel with the two phi...

Страница 16: ...lly set out of the way Fig 43 DO NOT kink or bend copper tubing or probe Remove four screws two at each end that hold the fan blower motor bracket in place Use a medium flathead screwdriver 7 For CA43...

Страница 17: ...eflector housing on your right as you are facing the front of heating module to the module with a medium 6 flathead screwdriver Fig 47 3 Gently lift the air deflector housing to access the nuts connec...

Страница 18: ...new gasket to attach new gasket to module Fig 54 4 Caulk inner and outer edges of new gasket with GE 1209 caulking Allow caulking to dry for at least 45 minutes Fig 55 5 Replace top mounted heating mo...

Страница 19: ...41 1601 outside of Texas andAlaska Your distributor can provide you with a current price list for replacement parts Or call the BEVLES manufacturing facilities for the most recent prices Common parts...

Страница 20: ...for CA70 Models Drawing Reference Number Description 1 1A 1B 2 2A 3 3A 4 4A 5 5A 6 7 8 9 10 11 12 13 14 14A 15 15A 16 17 18 19 20 21 22 23 23A 24 24A 25 25A 26 27 28 29 30 31 32 33 34 35 36 37 38 39...

Страница 21: ...High Temp Klixon Thermostat Rear Panel Rear Panel MP Elbow Connector Nut Lockwasher Elbow Connector Motor Housing Cover Motor Housing Cover MP Air Flow Cover Extension MP s s phillips MP or HW Models...

Страница 22: ...7 5a EXPLODED VIEW HEATING MODULE FOR CA70 MODELS 28 28A 29 31 32 1 1A 1B 17 16 13 7 6 2 2A 8 5 12 9 11 3 4 14 10 27 18 15 33 34 34A 20 21 24 22 22A 25 23 26 30 22...

Страница 23: ...14A 24A 24 26 28 29 31 32 25A 35 39 38 1 1A 1B 37 22 21 17 33 19 20 23A 23 3A 3 36 34 18 14 15A 15 16 4 4A 12 13 10 25 30 8 9 5 5A 6 7 11 27 2A 2 7 5b EXPLODED VIEW CABINET ASSEMBLY FOR CA70 MODELS 2...

Страница 24: ...7 5c EXPLODED VIEW HEATING MODULE FOR CA43 MODELS 28A 29 28 34 34A 31 32 30 1 1A 16 19 13 7 6 2 2A 8 5 3 4 9 10 11 12 14 20 37 37A 38 21 33 24 22 22A 25 23 26 1B 15 27 18 17 24...

Страница 25: ...7 5d EXPLODED VIEW CABINET ASSEMBLY FOR CA43 MODELS 1 1A 1B 19 20 22 21 17 33 6 6 7 3 3A 34 36 35 37 10 12 13 24A 24 23 23A 9 11 26 27 25 25A 30 31 32 28 29 8 2 2A 5 5A 25...

Страница 26: ...7 Ceramic Insulator Screw 6 32 x 1 4 s s phillips Lockwasher 6 s s Power Cord 14 3 SO Power Cord 12 3 SO Elbow Connector High Temp Klixon Lockwasher Elbow Connector Elbow Connector Nut Air Flow Cover...

Страница 27: ...mbly lower CV16 Air Duct Assembly upper CVMP12 Air Duct Assembly lower CVMP12 Wire Hanger MP Air Duct Assembly upper CVMP15 Air Duct Assembly lower CVMP15 Extruded Runner MP 7 6e Cabinet Parts List CA...

Страница 28: ...mostat Knob 8 32 10 24 x 1 2 s s phillips 1500W 120V 1800W 120V MP HW Mdls MP or HW Models Thermostat 12O 240V 7 6i Heating Module Parts List CA43 Mdls Dwg 7 5c Ref Description Part Number 2 2A 3 4 5...

Страница 29: ...illips 21 5 x 28 5 MP 26 x 28 5 MP 22 37 26 87 MP 22 37 26 87 MP 29 5 7 6m Cabinet Parts List CA43 Mdls Dwg 7 5d Ref Description Part Number 7 6n Cabinet Interior Parts List CA43 Mdls Dwg 7 5d Ref Des...

Страница 30: ...ANT FOR FUTURE REFERENCE Please complete this information and retain this manual for the life of the equipment For WARRANTYSERVICE and or PARTS this information is required Model Number Serial Number...

Страница 31: ...31 Notes...

Страница 32: ...65 0976 Toll Free 1 800 441 1601 Website www BevLes com E mail sales BevLes com 214 421 7366 BevLes 729 Third Avenue Dallas TX 75226 Innovative Foodservice Equipment Custom Designed for Performance Se...