b.

Initial Start-Up

Verify temperature control setting to be at the 2 o-clock position (reference single scribe mark on adjuster plate) and
connect cabinet electrical cord to electrical supply. Refrigeration system operation can be verified by the audible sound of
the compressor start-up and the presence of air movement exiting the compressor compartment and in the cabinet interior.
Contact a qualified service technician to correct any faults identified, at this point.

c.

Temperature Control

The temperature control is located in the refrigeration system compartment behind the ventilation panel (“grille”).  Removal
of the grille is not required, for control adjustment. The factory setting should maintain product at approximately 38 degrees
F.  Colder product temperatures require a clockwise adjustment of the slotted stem.  Allow 24 hours between control setting
changes.  Caution should be exercised when adjusting to colder settings.  In addition to the possibility of frozen product,
higher than normal energy consumption will be realized.

d.

Condensate Disposal

Condensate, generated by “off cycle” warming of the evaporator coil, is routed to the disposal pan located in the compressor
compartment.  The compressor discharge line is routed through the pan to heat the collected condensate.  Evaporation is
assisted by air flow directed from the condenser fan.

3.

  Maintenance

a.

Cleaning Cabinet Surfaces

To protect paint and decal surfaces, the cabinet exterior should be cleaned with a mild soap and water solution, only.  Use
of a soft fabric cloth will minimize scratches on sign medallion and shields.  

CAUTION

: Disconnect electrical service prior to

any cabinet clean-up in electrical parts / wiring areas.

b.

Condenser

To maintain acceptable compressor operating temperature and efficient refrigeration system operation, the condenser must
be cleaned periodically.  Cleaning intervals will vary according to cabinet proximity to customer traffic, location cleanliness,
humidity, etc.  After initial unit placement, it is recommended that the condenser face be inspected for blockage every other
month until the need for cleaning intervals is understood.  The condenser face should be brushed (vertically against face to
protect fin edges) whenever no greater than one forth of the total face area is obstructed.  Once per year, the condenser fan
blade should be cleaned.

c.

Condensate Pan

To protect against unwanted odors and maintain evaporation performance, the condensate pan should be cleaned periodically.
Access to the pan is gained by removal of the (2) screws which fasten the refrigeration system to cabinet base and sliding
the refrigeration system outward.  

CAUTION:

 Disconnect electrical service prior to this operation.

d.

Lamps

Sign medallion and interior fluorescent lamps must be replaced with parts having identical diameter, length and wattage.
Likewise, replacement lamp ballast must be of original equipment specification.  

CAUTION

: Failure to ensure proper matching

of lamp and ballast specifications can cause significant reduction in lamp and ballast life.

e.

Refrigeration System – Removal / Installation
CAUTION:

 Disconnect primary electrical service prior to this operation.  The entire refrigeration system can be removed as

a single unit.  Remove the service panel (grille) to access (2) fasteners securing the front unit surface.  Pull system forward
to access wire harness power disconnect feature, located behind compressor.  Once the harness is disconnected, the
system can be completely removed.  Prior to installation, the gasket seal on the evaporator fan panel must be inspected for
deterioration and replaced as required.

IL-2169A SHT 2

Содержание BZ13 Series

Страница 1: ...nspection includes complete refrigeration system cabinet construction finish IMPORTANT PLEASE RETAIN FOR YOUR RECORDS SALES OFFICE P O BOX 5932 SPARTANBURG S C 29304 5932 PHONE 864 582 8111 TOLL FREE 1 800 845 9800 TECHNICAL SERVICE 1 800 684 1199 PARTS ORDER FAX 1 800 262 9381 PLANTS SPARTANBURG S C BROOKVILLE PA HONEA PATH S C 809 062A rev B ...

Страница 2: ...ly adjustable to suit package size and presentation requirements Interior cooling airflow performance should be considered when establishing shelf to product spacing An equal spacing of shelves with no less than 1 2 54 cm between top surface of product and bottom surface of shelf top is recommended To ensure proper airflow product must not extend beyond the front or rear edge of the shelving and m...

Страница 3: ... maintain acceptable compressor operating temperature and efficient refrigeration system operation the condenser must be cleaned periodically Cleaning intervals will vary according to cabinet proximity to customer traffic location cleanliness humidity etc After initial unit placement it is recommended that the condenser face be inspected for blockage every other month until the need for cleaning i...

Страница 4: ......

Страница 5: ...cation mark cannot be seen Physically verify that the lamp has been rotated and locked into place See pictures below Caution Improperly installed lamps may cause damage to the lighting circuit Beverage Air shall have no liability whatsoever for equipment or component failures or other damages or losses which arise as a result of improper installation Bi pin lamp end identification mark Pins may no...

Страница 6: ......

Страница 7: ......

Страница 8: ......

Страница 9: ...l setting 1 Loose parts or mountings 2 Tubing rattle 3 Bent fan blade causing vibration 4 Fan motor bearings worn SOLUTION 1 Plug in line cord 2 Replace fuse 3 Refer to electrical section 4 Repair or replace control 5 Check wiring against diagram 1 Check wiring against diagram 2 Determine reason and correct 3 Determine reason and replace 4 Determine reason and correct replace if necessary 1 Determ...

Страница 10: ...ince most field type vacuum pumps cannot pull a low enough vacuum to remove moisture from the system it is recommended that the system be triple evacuated breaking each time with dry refrigerant nitrogen Use care to purge air from the charging hose when breaking the vacuum 왎 CHARGING REFRIGERATION SYSTEM Since capillary tube systems have small critical refrigerant charges we recommend that a field...

Страница 11: ...SERVICE RECORD ...

Отзывы: