Trouble Diagnosis for the User
Malfunction

Possible Cause

Likely Solution

No cooling - unit is silent

Unit not plugged in.
Fuse or circuit breaker tripped. 
Power cord plug loose in outlet.

Connect to proper voltage circuit Replace 
fuse or reset breaker.
Check outlet for loose connection, replace 
as needed

Unit cools but seems to be on all the time

Dirty condenser

Clean condenser

Space temperature too high

Dirty condenser
Evaporator iced over Unit in high 
temperature environment

Clean condenser Defrost evaporator
Reduce temperature of room

Space temperature too low

Temperature control   

Adjust or replace control

Trouble Diagnosis for the Technician
No cooling - compressor does not hum

Temp control stuck in open position

Replace temp control.

No cooling - compressor hums but does not 
start

Low voltage to unit.
Compressor starting  system failure

Check voltage, correct as needed. Check 
start relay and start capacitor. See next 
step.

No cooling - compressor starts but shuts 
off

Compressor start relay failure Compressor 
start capacitor failure

Replace relay. Replace capacitor.

No cooling - compressor cycles on and off

Overheating weak overload

Clean condenser, check fan motor and 
blade. Check refrigerant charge. Replace 
overload.

Unit cools, but is slow to pull cabinet 
temperature down

Evaporator fan not turning

Check fan(s), on multiple fan units one fan 
may be turning slowly and will need to be 
replaced.

Unit cools but turns on and off frequently

No product in cabinet. Temperature control 
defective Refrigeration issue

Fill cabinet Replace control
Have system checked

Makes excessive noise    

Tubing rattle Loose parts
Bent or broken fan blade Noisy fan motor

Check tubing for routing Check for loose 
components Replace fan blade
Replace fan motor

Содержание BB Series

Страница 1: ...NSTRUCTIONS for all Hydrocarbon BB Back Bar Refrigerator Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web beverage air com 809 183a Rev A 6 8 2020 SEE BACK COVE...

Страница 2: ...ranty registration information is located with this manual Please complete the card and submit it to Beverage Air within TEN days of installation Failure to properly register equipment may limit or vo...

Страница 3: ...gers There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other fl...

Страница 4: ...ered in any way Alterations or part substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overheated or subjected...

Страница 5: ...User Manual for BB Refrigerators Beverage Air Rev 06 20 Beverage Air 5 Air Flow 36 48 inch Models regardles of section door count or door material...

Страница 6: ...age Air Rev 06 20 Beverage Air 6 Air Flow 58 94 inch Models regardles of left or right grille location section door count or door material Left grille shown right grille similar but air flows in the r...

Страница 7: ...1 4 2 Solid 5 3 5 15P R 290 115 BB68HC 1 G 69 x 29 1 8 x 37 1 4 2 Glass 5 3 5 15P R 290 115 BB72HC 1 72 x 24 1 2 x 34 3 Solid 3 1 5 15P R 290 80 BB72HC 1 G 72 x 24 1 2 x 34 3 Glass 3 1 5 15P R 290 80...

Страница 8: ...uired at top back or sides Floor Load the floor on which the Refrigerator is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and maxim...

Страница 9: ...m should be visible once screwed in 3 Tilt the cabinet in one direction approximately 8 and block it securely with pieces of 2x4 lumber or other suitable material 4 Thread the stem casters or legs int...

Страница 10: ...ps 5 Install shelves onto clips with the product retention bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf a...

Страница 11: ...ust be maintained figure 3a while pulling the door bottom 3 Once the bottom of the door has cleared the track pull the door slowly away from the self closing device as it retracts and awy from the cab...

Страница 12: ...rame or rubbing the frame header 4 Self closing spring is properly attached to its nylon retaining pillar in the frame header C channel and is not kinked in any way 5 Door is sitting on its wheels the...

Страница 13: ...4 Remove the dust cap from the new cylinder and attach the regulator to the new cylinder with the Gold Regulator Nut Make sure all sealing washers are in place before connecting 5 Open the Cylinder V...

Страница 14: ...rd and 5 15P plug If the power cord becomes damaged it must be replaced with the identical cord Follow All National and Local Codes This unit must be grounded Do not use extension cords and do not dis...

Страница 15: ...s 4 clearance between product and ceiling and 1 clearance from the bottom of the unit No provision is made in the cabinets to quickly pull a keg of beer down to temperature Best results are obtained w...

Страница 16: ...ff when the Compressor is not running The Condenser Fan is wired directly to the Compressor not through the controller EVAPORATOR FAN The Evaporator Fan runs continuously in refrigerators When the uni...

Страница 17: ...t Point Long press and release Increases display brightness DOWN Quick press and release Decreases Set Point Long press and release Decreases display brightness DEFROST ESC Quick press and release Act...

Страница 18: ...el Connections Changing the Set point Electronic Controller Alarms The alarm condition is always signaled by the alarm icon To turn off the relative icon will continue flashing NOTE If alarm exclusion...

Страница 19: ...lay beep the buzzer Door open alarm uHi Line voltage is higher than Cop uHi Always Blink uHi If configu red cut in alarm relay beep the buzzer High voltage alarm uLi Line voltage is higher than Cop uL...

Страница 20: ...perature 2 Disconnect power to the unit unplug it or switch the breaker off 3 Remove all loose food particles from the inside walls floor door liner and ceiling 4 Scrub all interior surfaces and door...

Страница 21: ...and compressor failure and may result in loss of property Failure to keep the condenser coil clean may void the limited warranty Chemical Cleaning 1 Remove power from the unit 2 A chemical condenser c...

Страница 22: ...mall amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Disc...

Страница 23: ...emp control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check start relay and start capacitor See next step No...

Страница 24: ...venting MUST be in an area free from flame or spark It must be near an opend window or door A sign noting service of a system containing propane must be attached to the unit during refrigeration servi...

Страница 25: ...E TECH WIRING DIAGRAM WHITE 2 1 BLACK EVAP FANS SEE CONTROLLER DETAIL 2 3 SEE CONTROLLER DETAIL WHITE BLACK BLACK WHITE COMPRESSOR DETAIL 115V 1PH COMP CONDENSER FAN C OL R S S CURRENT RELAY 1 M 2 4 S...

Страница 26: ...AGE AIR Also this extended compressor part only warranty does NOT apply to any electrical controls condenser evaporator fan motors overload switch starting relay capacitors temperature control filter...

Страница 27: ...AND WE NEITHER ASSUME NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS THERE OF This warranty shall not...

Страница 28: ..._____________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name _____________________________________________...

Отзывы: