12

ADJUSTING SPRING TENSION

1.  Adjust the spring tension if the door(s) do not fully close.

2.  First, remove the door that does not fully close.

3.  After removal of the door, remove the spring installation 

screw (figure 4a), and slide the nylon spring pillar over 
one notch toward the handle side of the door (figure 4b 
& 4c), so that it increases the tension in the spring.

4.  Reinstall the nylon spring screw in the new location.

5.  Replace the door and check for proper alignment and 

operation with the new tension setting.

6.  Repeat this for each door that requires adjustment.

CLEANING

Door frames should be cleaned with a solution of mild soap 
and water. Do not use caustic soap or abrasive cleaners, 
since these might damage the finish.

If stainless steel roller track surfaces become discolored, 
scrub by rubbing along the length of the track. Do not use 
steel wool.

Clean glass surfaces with a standard glass cleaning solution.

TROUBLESHOOTING

If doors do NOT operate properly, check for the following:

1.  Minimum of 1/32" of CLEARANCE between the vertical 

gaskets on the COLD S IDE doors and the horizontal 
frame gaskets located at the header and sill of the frame 
in between the doors.

2.  Self-closing device (a.k.a. "Torpedo· ) is properly located 

on edge of door and is not "pinched" or "bound· between 
the top of the door and the frame, and that torpedo 
operates smoothly.

3.  Sash covers on doors are properly snapped into place 

and have NOT slipped down, and are NOT dragging on 
the sill track of the frame or rubbing the frame header.

4.  Self-closing spring is properly attached to its nylon 

retaining pillar in the frame header C-channel and is not 
kinked in any way.

5.  Door is sitting on its wheels, the wheels are properly 

aligned on the stainless steel roller track, and the door 
moves freely back and forth.

6.  Door is not bowed in or out from top to bottom causing 

doors to rub on frame or frame gaskets.

7.  Cabinet is relatively level (within approximately 3/16" of 

level across the full width of the frame).

8.  Sill tracks with stainless steel roller track covers are 

properly snapped into p lace and are not bowed up or 
down across the width of the frame.

If installed doors do NOT close fully after above checks are 
complete, then consider increasing the tension on the self-
closing spring(s) by:

1.  Removing door(s) that are not closing properly.

2.  Removing spring installation screw and sliding nylon 

spring pillar over one notch so that it increases the 
tension in the spring when it is at rest. Reinstall the 
nylon spring screw in this new location.

3.  Reinstall the door(s).

4.  Check for proper operation of doors with increased 

spring tension.

If installed doors still do NOT close fully after above checks 
and adjustments, then install stronger spring(s):

1.  Verify that the sill track is fully engaged (snapped) into 

the channel over the sill track"s entire length.

2.  Verify that the frame seals are fully seated in the frame. 

If the seals are not fu lly seated, they could interfere 
with the movement of the door.

3.  Verify that the frame was not bowed during installation. 

If the frame is bowed, contact Beverage-Air Technical 
Service.

If installed doors still do NOT close fully after all of the 
above checks, contact Beverage-Air Technical Service.

Figure 4c

Содержание BB Series

Страница 1: ...NSTRUCTIONS for all Hydrocarbon BB Back Bar Refrigerator Models 3779 CHAMPION BLVD WINSTON SALEM NC 27105 Phone 888 845 9800 Fax 800 253 5168 Web beverage air com 809 183a Rev A 6 8 2020 SEE BACK COVE...

Страница 2: ...ranty registration information is located with this manual Please complete the card and submit it to Beverage Air within TEN days of installation Failure to properly register equipment may limit or vo...

Страница 3: ...gers There may be pinch points near the door hinges Maintenance Do NOT Clean a frozen evaporator with a sharp object Clean a dirty condenser with a sharp object Store gasoline kerosene or any other fl...

Страница 4: ...ered in any way Alterations or part substitutions will void the warranty Limitations The machine is designed for use indoors in a controlled environment It must be kept dry not overheated or subjected...

Страница 5: ...User Manual for BB Refrigerators Beverage Air Rev 06 20 Beverage Air 5 Air Flow 36 48 inch Models regardles of section door count or door material...

Страница 6: ...age Air Rev 06 20 Beverage Air 6 Air Flow 58 94 inch Models regardles of left or right grille location section door count or door material Left grille shown right grille similar but air flows in the r...

Страница 7: ...1 4 2 Solid 5 3 5 15P R 290 115 BB68HC 1 G 69 x 29 1 8 x 37 1 4 2 Glass 5 3 5 15P R 290 115 BB72HC 1 72 x 24 1 2 x 34 3 Solid 3 1 5 15P R 290 80 BB72HC 1 G 72 x 24 1 2 x 34 3 Glass 3 1 5 15P R 290 80...

Страница 8: ...uired at top back or sides Floor Load the floor on which the Refrigerator is located must be even and level free from vibrations and strong enough to support the combined weights of the unit and maxim...

Страница 9: ...m should be visible once screwed in 3 Tilt the cabinet in one direction approximately 8 and block it securely with pieces of 2x4 lumber or other suitable material 4 Thread the stem casters or legs int...

Страница 10: ...ps 5 Install shelves onto clips with the product retention bar facing up Be careful not to dislodge clips during installation 6 Place shelves so that the retaining tab on the clip captures the shelf a...

Страница 11: ...ust be maintained figure 3a while pulling the door bottom 3 Once the bottom of the door has cleared the track pull the door slowly away from the self closing device as it retracts and awy from the cab...

Страница 12: ...rame or rubbing the frame header 4 Self closing spring is properly attached to its nylon retaining pillar in the frame header C channel and is not kinked in any way 5 Door is sitting on its wheels the...

Страница 13: ...4 Remove the dust cap from the new cylinder and attach the regulator to the new cylinder with the Gold Regulator Nut Make sure all sealing washers are in place before connecting 5 Open the Cylinder V...

Страница 14: ...rd and 5 15P plug If the power cord becomes damaged it must be replaced with the identical cord Follow All National and Local Codes This unit must be grounded Do not use extension cords and do not dis...

Страница 15: ...s 4 clearance between product and ceiling and 1 clearance from the bottom of the unit No provision is made in the cabinets to quickly pull a keg of beer down to temperature Best results are obtained w...

Страница 16: ...ff when the Compressor is not running The Condenser Fan is wired directly to the Compressor not through the controller EVAPORATOR FAN The Evaporator Fan runs continuously in refrigerators When the uni...

Страница 17: ...t Point Long press and release Increases display brightness DOWN Quick press and release Decreases Set Point Long press and release Decreases display brightness DEFROST ESC Quick press and release Act...

Страница 18: ...el Connections Changing the Set point Electronic Controller Alarms The alarm condition is always signaled by the alarm icon To turn off the relative icon will continue flashing NOTE If alarm exclusion...

Страница 19: ...lay beep the buzzer Door open alarm uHi Line voltage is higher than Cop uHi Always Blink uHi If configu red cut in alarm relay beep the buzzer High voltage alarm uLi Line voltage is higher than Cop uL...

Страница 20: ...perature 2 Disconnect power to the unit unplug it or switch the breaker off 3 Remove all loose food particles from the inside walls floor door liner and ceiling 4 Scrub all interior surfaces and door...

Страница 21: ...and compressor failure and may result in loss of property Failure to keep the condenser coil clean may void the limited warranty Chemical Cleaning 1 Remove power from the unit 2 A chemical condenser c...

Страница 22: ...mall amount of cleaner Heat tint or discoloration Penny Brite or Copper Brite Past NuSteel DuBois Temp or Tarnite Revere Stainless Steel Cleaner Allen Polish Steel Bright Tenacious Deposits Rusty Disc...

Страница 23: ...emp control No cooling compressor hums but does not start Low voltage to unit Compressor starting system failure Check voltage correct as needed Check start relay and start capacitor See next step No...

Страница 24: ...venting MUST be in an area free from flame or spark It must be near an opend window or door A sign noting service of a system containing propane must be attached to the unit during refrigeration servi...

Страница 25: ...E TECH WIRING DIAGRAM WHITE 2 1 BLACK EVAP FANS SEE CONTROLLER DETAIL 2 3 SEE CONTROLLER DETAIL WHITE BLACK BLACK WHITE COMPRESSOR DETAIL 115V 1PH COMP CONDENSER FAN C OL R S S CURRENT RELAY 1 M 2 4 S...

Страница 26: ...AGE AIR Also this extended compressor part only warranty does NOT apply to any electrical controls condenser evaporator fan motors overload switch starting relay capacitors temperature control filter...

Страница 27: ...AND WE NEITHER ASSUME NOR AUTHORIZE ANY OTHER PERSON TO ASSUME FOR US ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE SALE OF SAID REFRIGERATION UNITS OR ANY PARTS THERE OF This warranty shall not...

Страница 28: ..._____________ Date Of Installation _________________ Cabinet Serial Number _____________________________________________ Location Of Product Business Name _____________________________________________...

Отзывы: