 Important

Do not boil or autoclave the masks and air hose.

• Once all components are fully dry, reassemble the 

atomiser and place the components in a dry, sealed 

container.

 Note

Ensure that all parts are thoroughly dried during, and 

in particular after cleaning, otherwise there is an in-

creased risk of bacterial growth.

Drying

•  Place the individual components on a dry, clean and 

absorbent surface and allow to dry completely (for 

at least 4 hours).

Material resistance

• As with all plastic components, frequent use and 

cleaning of the atomiser and the accessories can 

lead to a certain amount of wear. Over time, this can 

alter the aerosol properties and may eventually affect 

the efficiency of therapy. We therefore recommend 

that you replace the atomiser once a year.

•  When choosing a cleaning or disinfecting agent, note 

the following: Only use mild cleaning or disinfect-

ant agents in the quantities recommended by the 

manufacturer.

Storage

• Do not store the nebuliser in a damp atmosphere 

(e.g. in the bathroom) or transport it together with 

damp objects.

• Store and transport the nebuliser away from direct 

sunlight.

•  Store the device in a dry place, if possible in its origi-

nal packaging.

9. Disposal

In the interest of environmental protection, do 

not dispose of the device in household waste.

Please dispose of the device in accordance with 

EC Directive – 

WEEE

 (Waste Electrical and Electronic 

Equipment). 

If you have any queries, please contact the appropriate 

local authorities.

10. Troubleshooting

Problem/Ques-

tion

Possible Cause/Remedy

The atomiser 

produces

little or no 

aerosol.

1.  Too much or too little medicine 

in the atomiser. 

Minimum: 2 ml,  

Maximum: 8 ml.

2.  Check that the nozzles are not 

blocked If necessary, clean 

the nozzle (e.g. by rinsing). 

Use the atomiser again.

     CAUTION: 

Only poke imple-

ments through the fine holes 

from the underside of the 

nozzle.

3.  The atomiser is not held in an 

upright position.

4.  The medicine solution is 

unsuitable for nebulising (e.g. 

too thick).  

The medicine solution should 

be specified by the doctor.

Output is too 

low.

Hose kinked, filter blocked, too 

much inhalation solution.

Which 

medicines are 

suitable for 

inhalation?

Consult your doctor.

 

Essentially all medicines that 

are suitable and approved for 

device-based inhalation can be 

inhaled.

Some inhalation 

solution

remains in the 

atomiser.

This is normal and occurs for 

technical reasons. Stop inhala-

tion if you hear a notable differ-

ence in the noise of the atomiser.

What special 

steps should be 

taken for babies 

and children?

1.  In babies, the mask should 

cover the mouth and nose to 

guarantee effective inhalation.

2.  In children, the mask should 

also cover the mouth and 

nose. Nebulisation next to a 

sleeping person is not suitable 

because insufficient medicine 

reaches the lungs.

Note:

 Children should only use 

the device with help and under 

supervision of an adult. Never 

leave a child alone with the 

nebuliser.

Inhalation with 

the mask takes 

longer.

This is for technical reasons. 

Less medicine is inhaled per 

breath through the mask holes 

than using the mouthpiece. The 

aerosol is mixed with ambient air 

through the holes in the mask.

Содержание IH 18

Страница 1: ...IH 18 EN Nebuliser Instructions for use ...

Страница 2: ...chi deep into the lungs Exhale normally Once prepared the device is suitable for reuse The prep aration includes the replacement of all accessory parts including atomiser and air filter as well as disinfection of the surfaces of the device with a standard disinfectant Please note that all accessories should be replaced if the device is used by more than one person We recommend that you replace the...

Страница 3: ...ldren Do not use attachments that are not recommended by the manufacturer Connect the unit only to the mains voltage listed on the type plate Do not dip the unit into water and do not use it in wet rooms Do not allow any liquid to penetrate the unit Protect the unit from strong impacts Never touch the mains cable with wet hands this can cause an electric shock Do not pull the mains plug from the s...

Страница 4: ...gainst dust dirt and moisture Never cover the unit during operation Do not use the unit in very dusty environments Switch the unit off immediately if it is defective or malfunctioning The manufacturer shall not be held liable for damage or injuries caused by improper or incorrect use Repairs Note Never open or attempt to repair the unit yourself as otherwise proper function is no longer guaranteed...

Страница 5: ...t medicines are to be inhaled in suc cession during therapeutic use the atomiser 7 must be rinsed under warm tap water after each use For information about this see Cleaning and disinfec tion on page 7 Follow the instructions for changing the filter con tained in these instructions Before each use check that the hose connections on the nebuliser 4 and the atomiser 7 are tight Before use check that...

Страница 6: ...g and drops for application to the skin or for use in steam baths are wholly unsuitable for inha lation using a nebuliser These substances are often highly viscous and can impair the correct function of the device and hence affect the effectiveness of its application in the long term In the case of oversensitivity of the bronchial system medicines containing essential oils can sometimes cause acut...

Страница 7: ...ver use any substances that may be poisonous when in contact with the skin or mucous membranes or when swallowed or inhaled Use a soft dry cloth and non abrasive cleaning prod ucts to clean the device Do not use abrasive detergents and never immerse the unit in water Important Ensure that no water penetrates inside the unit Do not put the device or accessories in a dishwasher Do not touch the unit...

Страница 8: ...ocal authorities 10 Troubleshooting Problem Ques tion Possible Cause Remedy The atomiser produces little or no aerosol 1 Too much or too little medicine in the atomiser Minimum 2 ml Maximum 8 ml 2 Check that the nozzles are not blocked If necessary clean the nozzle e g by rinsing Use the atomiser again CAUTION Only poke imple ments through the fine holes from the underside of the nozzle 3 The atom...

Страница 9: ...060 hPa Aerosol Properties Flow 5 31 l min Aerosol delivery 0 171 ml Aerosol delivery rate 0 082 ml min Particle size MMAD 3 16 µm The serial number is located on the device or in the battery compartment Subject to technical modifications Particle size diagram Measurements were performed using a sodium fluoride solution with a Next Generation Impactor NGI This diagram may not be applicable for sus...

Страница 10: ...er sonal purposes in the context of domestic use German law shall apply During the warranty period should this product prove to be incomplete or defective in functionality in accord ance with the following provisions Beurer shall carry out a repair or a replacement delivery free of charge in accordance with these warranty conditions If the buyer wishes to make a warranty claim they should approach...

Страница 11: ...11 ...

Страница 12: ...12 601 16_IH18_2019 12 16_05_IM2_BEU_EN Beurer GmbH Söflinger Straße 218 89077 Ulm Germany www beurer com www beurer healthguide com ...

Отзывы: