Selecting the user

You have 2 memories, each with 60 memory spaces, to 

enable the separate storage of measurements for 2 dif-

ferent people. 

To select the corresponding user memory, press the 

M1

 

memory button (for user  ) or 

M2

 (for user  ) on the 

switched-off device. Confirm your selection by pressing 

the 

START/STOP

 button  .

Performing the blood pressure measurement

As described above, attach the cuff and adopt the pos-

ture in which you want to perform the measurement.

•  Press the 

START/STOP

 button   to 

start the blood pressure monitor. All 

displays will illuminate briefly.

The blood pressure monitor will begin 

the measurement automatically after 5 

seconds.

The cuff automatically inflates. The 

measurement itself is taken during the inflation phase.

As soon as a pulse is found, the pulse symbol   is dis-

played.

  You can cancel the measurement at any time by 

pressing the 

START/STOP

 button  .

•  The systolic pressure, diastolic pres-

sure and pulse rate measurements 

are displayed.

• 

 appears if the measurement could 

not be performed properly. Observe 

the chapter „9. What if there are prob-

lems?“ in these instructions for use and repeat the 

measurement.

•  Press the 

START/STOP

 button   to switch 

off the blood pressure monitor. The measure-

ment is then stored in the selected user memory. 

If 

Bluetooth

®

 data transfer

 is activated, data is trans-

ferred after pressing the 

START/STOP

 button  . 

 The 

Bluetooth

®

 symbol flashes on the dis-

play. The blood pressure monitor now attempts 

to connect to the app for approx. 30 seconds. 

 The 

Bluetooth

®

 symbol stops flashing as soon as a 

connection is established. All measurement data is au-

tomatically transferred to the app. Once the data has 

been successfully transferred, the device switches off. 

•   If a connection to the app cannot be established after 

30 seconds, the 

Bluetooth

®

 symbol goes out and the 

1

2

3

4

5

6

7

8

9

10

11

Содержание BC 54

Страница 1: ...EN Blood pressure monitor Instructions for use BC 54...

Страница 2: ...nty Service 20 Table of contents Read these instructions for use carefully and keep them for later use be sure to make them accessible to other users and observe the information they contain Dear cust...

Страница 3: ...ging and on the type plate for the device WARNING Warning instruction indicating a risk of in jury or damage to health CAUTION Safety note indicating possible damage to the device accessory Product in...

Страница 4: ...and pulse values on the wrist Target group It is designed for self measurement by adults in the home environment and is suitable for users whose wrist circum ference is within the range printed on the...

Страница 5: ...or intravascular therapy or an arteriovenous AV shunt General warnings The measurements taken by you are for your informa tion only they are no substitute for a medical examina tion Discuss the measu...

Страница 6: ...ice has been stored close to the maximum or minimum storage and transport temperatures and is placed in an environment with a temperature of 20 C it is recommended that you wait approx 2 hours before...

Страница 7: ...ces or stacked on top of other devices as this could lead to faulty operation If however it is necessary to use the device in the manner stated this device as well as the other devices must be monitor...

Страница 8: ...LR03 batteries Make sure that the batteries are inserted the correct way round Do not use rechargeable batteries Close the battery compartment lid again carefully Now set the date and time as describ...

Страница 9: ...ou will not be able to save your measured values correctly with a date and time and access them again later Hour format The hour format now flashes on the display Select the desired hour format us ing...

Страница 10: ...profile of the progression of your blood pressure as possible and ensure that the measured values can be compared you should measure your blood pressure regularly and always at the same times of day...

Страница 11: ...the device display are facing upwards Position the cuff so that there is a distance of 1 0 1 5 cm between it and the heel of your hand Now fasten the cuff tightly around your wrist using the hook and...

Страница 12: ...el the measurement at any time by pressing the START STOP button The systolic pressure diastolic pres sure and pulse rate measurements are displayed appears if the measurement could not be performed p...

Страница 13: ...easurements therefore do not provide reli able information about the actual blood pressure Reli able assessment is only possible when you perform the measurement regularly under comparable conditions...

Страница 14: ...y factors such as heart disease age physical disposition excess alcohol and tobacco stress or lack of sleep If the symbol appears on the display after the measurement the measurement must be repeated...

Страница 15: ...yed in this example measure ment 03 If you press the memory button M1 once more you can view your individual measured values To switch the device off again press the START STOP button You can exit the...

Страница 16: ...ansferred automatically after the measurement The symbol appears in the top left of the display see chapter 6 Initial use section Bluetooth When connecting for the first time a randomly gen erated six...

Страница 17: ...fact that the software to hand is not a medical product in accordance with EU Directive 93 42 EEC The values displayed are purely for visualisation purposes and must not be used as a basis for therap...

Страница 18: ...le cause Solution 7 The data could not be sent via Bluetooth Proceed as described in chapter 7 Usage under the section Transfer via Blue tooth into the manual memory mode and try to restart the data t...

Страница 19: ...el no BC 54 Measurement method Oscillometric non invasive blood pressure measurement on the wrist Measurement range Cuff pressure 0 299 mmHg Systolic 60 230 mmHg Diastolic 40 130 mmHg Pulse 40 199 bea...

Страница 20: ...ical electrical equipment Part 2 30 Particular requirements for the basic safety and essential performance of automated non invasive sphygmomanometers The accuracy of this blood pressure monitor has b...

Страница 21: ...shall only be considered if the buyer can provide Beurer or an authorised Beurer partner with a copy of the invoice purchase receipt and the original product The following are explicitly excluded from...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...ames are those of their respective owners Apple and the Apple logo are trademarks of Apple Inc registered in the U S and other countries App Store is a service mark of Apple Inc registered in the U S...

Отзывы: