Mini Speed Dome Camera Introduction Manual
29
▌▌
Alarm Input Setup
(For External mini PTZ Dome only)
<DOME CAMERA SETUP>
→
<ALARM SETUP>
Match the Alarm sensor input to one of Preset Positions
/Home/Auto Scan/Group/Pattern/Swing. If an external sensor
is activated, camera will corresponding command position
when this item is predefined.
Alarm Enable
[ON/OFF]
Establish the current passage reports to the
police open of function with pass
Alarm No.
[001~004]
Select alarm channel number
Alarm x Action [NOTHING/PRESET/PATTERN/SWING/
GROUP]
Assign counteraction Preset position to each
Alarm input.
Release Time
[001~240 S]
Alarm output time is postponed to a certain
time, adjustable range is 0 sec t 240 sec.
Start Fan
[20~60ºC]
Ex) If set start fan is 30ºC, the dome will start
fan when above 30ºC, and it will stop to fan
when temperature is lower than set value
5ºC.
Start Heater [-20~10ºC]
Ex) If set start fan is -10ºC, the dome will start
heat when above -10ºC, and it will stop to
heat when temperature is higher than set
value 5ºC.